혈액 이송을 위한 열전소자 저장용기에 관한 연구
A Study on Thermoelectric Element Storage Containers for the Transport of Whole Blood Products
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this paper, we developed a thermoelectric storage container that maintains whole blood temperature and studied its characteristics. Using a temperature sensor, we compared the internal temperature with the set temperature in real time and maintained the temperature between 1 and 6°C. In addition, we installed insulation inside the container and used a lithium-ion battery to power the system to ensure a stable whole blood temperature even during long-distance transportation. Instead of a blood pack, a 350-g water bottle was used and the experiment was conducted at an ambient temperature of 25°C. After cooling for 10 minutes, the internal temperature of the container reached 6°C and the battery operated for 60 minutes. In the future, if we improve the thickness and thermal conductivity of the insulation installed in the thermoelectric storage container and utilize phase change materials as a supplement, we will be able to transport more diverse blood products and special reagents stably.
Abstract
In this paper, we developed a thermoelectric storage container that maintains whole blood temperature and studied its characteristics. Using a temperature sensor, we compared the internal temperature with the set temperature in real time and maintained the temperature between 1 and 6°C. In addition, we installed insulation inside the container and used a lithium-ion battery to power the system to ensure a stable whole blood temperature even during long-distance transportation. Instead of a blood pack, a 350-g water bottle was used and the experiment was conducted at an ambient temperature of 25°C. After cooling for 10 minutes, the internal temperature of the container reached 6°C and the battery operated for 60 minutes. In the future, if we improve the thickness and thermal conductivity of the insulation installed in the thermoelectric storage container and utilize phase change materials as a supplement, we will be able to transport more diverse blood products and special reagents stably.
참고문헌 (9)
- Ro, S. T, "Principle of thermoelectric refrigeration and system design", Korean J. of Air-Conditioning and Refrigeration Eng, 19(3), pp.135~145 (1990)
- Stockholm, J. G., "Current state of Peltier cooling", 26th Int. Conference of Thermoelectrics, Design (1997)
- Jeong, E. S., "Optimization of thermo-electric elements for thermoelectric coolers", Korean J. of Air-Conditioning and Refrigeration Eng, 24(5), pp.409~414 (2012)
- Attey, G. S., "Enhanced thermoelectric refrigeration system COP through low thermal impedance liquid heat transfer system", Proceedings of the 7th international Conference on Thermoelectrics, pp.519~524 (1998)
- Gorodetskiy, S. M., "Determination of TE module parameters", Proceedings of the 18th Int. Conference on Thermoelectrics, pp.266~269 (1990)
- Yamanish, M., "A new approach to optimum design in thermoelectric cooling system", J. Applied Physics, 80, pp.5494~5512 (1996)
- Kang, B. H., "Cooling characteristics at hot side of the thermoelectric module for an air conditioner", Korean Journal of Refrigeration and Air Conditioning, 14(3), pp.482~488 (2002)
- Solomon, M., "Determination of thermoelectric module parameters", proceedings of the 18th International Conference on Thermoelectrics, pp.519~524 (2002)
- Hwang, J., "Effects of thermoelectric module arrangement on the performance of a thermoeletric air-cooling system", Korean J. of Air Conditioning and Refrigeration Eng, 19(2), pp.162~168 (2007)