본문 바로가기
KERD
논문KCI 등재

AESA방식 MFR 송수신 모듈간 온도 균일화를 위한 수랭식 냉각판 유로 채널 디자인 설계에 관한 연구

A Study on the Design of Liquid Cooled Cold Plate Flow Channel for Inter-Module Temperature Uniformity in Active Electronically Scanned Array Type Multi-function Radar Transmit/Receive Modules

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기계공학

초록

Active electronically scanned array (AESA) multi-function radars (MFRs) comprise numerous transmit/receive modules (TRMs) whose maximum temperature and temperature uniformity must be tightly controlled. This study proposes a new liquid-cooling-plate flow-channel design for an X-band AESA MFR: a two-layer straight channel incorporating multiple fins irregularly spaced along the flow channel. The proposed design (Type-4) is compared with three baseline channel designs. At the same coolant flow rate, Type-4 reduces the TRM maximum temperature by 28.2 K and the maximum inter-module temperature difference by 19.7 K relative to Type-1. However, the pressure drop increases by 726% because of the added internal surfaces and fins which are flow obstructions. A comprehensive thermo-hydraulic comparison, including pumping power criteria, is conducted over multiple flow-rate conditions. Overall performance was highest for Type-4, followed by Type-2, Type-3, and Type-1. When designs achieve similar maximum temperature and temperature difference with various coolant flowrate condition, Type-2 requires 83.6% less pumping power than Type-1, and Type-4 requires 33.8% less pumping power than Type-2.

Abstract

Active electronically scanned array (AESA) multi-function radars (MFRs) comprise numerous transmit/receive modules (TRMs) whose maximum temperature and temperature uniformity must be tightly controlled. This study proposes a new liquid-cooling-plate flow-channel design for an X-band AESA MFR: a two-layer straight channel incorporating multiple fins irregularly spaced along the flow channel. The proposed design (Type-4) is compared with three baseline channel designs. At the same coolant flow rate, Type-4 reduces the TRM maximum temperature by 28.2 K and the maximum inter-module temperature difference by 19.7 K relative to Type-1. However, the pressure drop increases by 726% because of the added internal surfaces and fins which are flow obstructions. A comprehensive thermo-hydraulic comparison, including pumping power criteria, is conducted over multiple flow-rate conditions. Overall performance was highest for Type-4, followed by Type-2, Type-3, and Type-1. When designs achieve similar maximum temperature and temperature difference with various coolant flowrate condition, Type-2 requires 83.6% less pumping power than Type-1, and Type-4 requires 33.8% less pumping power than Type-2.

관련 논문AI추천

이 간행물의 다른 논문 (49건)