본문 바로가기
KERD
논문KCI 미등재

Standardizing HER2 immunohistochemistry assessment: calibration of color and intensity variation in whole slide imaging caused by staining and scanning

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류자연과학일반

초록

In the evaluation of human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) — one of the standard biomarkers for breast cancer— visual assessment is laborious and subjective. Image analysis using whole slide image (WSI) could produce more consistent results; however, color variability in WSIs due to the choice of stain and scanning processes may impact image analysis. We therefore developed a calibration protocol to diminish the staining and scanning variations of WSI using two calibrator slides. The IHC calibrator slide (IHC-CS) contains peptide-coated microbeads with different concentrations. The color distribution obtained from the WSI of stained IHC-CS reflects the staining process and scanner characteristics. A color chart slide (CCS) is also useful for calibrating the color variation due to the scanner. The results of the automated HER2 assessment were compared to confirm the effectiveness of two calibration slides. The IHC-CS and HER2 breast cancer cases were stained on different days. All stained slides and CCS were digitized by two different WSI scanners. Results revealed 100% concordance between automated evaluation and the pathologist’s assessment with both the scanner and staining calibration. The proposed method may enable consistent evaluation of HER2.

Abstract

In the evaluation of human epidermal growth factor receptor 2 (HER2) immunohistochemistry (IHC) — one of the standard biomarkers for breast cancer— visual assessment is laborious and subjective. Image analysis using whole slide image (WSI) could produce more consistent results; however, color variability in WSIs due to the choice of stain and scanning processes may impact image analysis. We therefore developed a calibration protocol to diminish the staining and scanning variations of WSI using two calibrator slides. The IHC calibrator slide (IHC-CS) contains peptide-coated microbeads with different concentrations. The color distribution obtained from the WSI of stained IHC-CS reflects the staining process and scanner characteristics. A color chart slide (CCS) is also useful for calibrating the color variation due to the scanner. The results of the automated HER2 assessment were compared to confirm the effectiveness of two calibration slides. The IHC-CS and HER2 breast cancer cases were stained on different days. All stained slides and CCS were digitized by two different WSI scanners. Results revealed 100% concordance between automated evaluation and the pathologist’s assessment with both the scanner and staining calibration. The proposed method may enable consistent evaluation of HER2.

참고문헌 (17)

  1. P. F. Alcantarilla, , Proc. British Machine Vision Conference (2013)
  2. P. Bankhead, "QuPath: Open source software for digital pathology image analysis", Sci. Rep, 7(1), pp.16878~ (2017)[DOI]
  3. P. A. Bautista, "Color standardization in whole slide imaging using a color calibration slide", J. Pathol. Inform, 5(1), pp.4~ (2014)[DOI]
  4. S. A. Bogen, "A root cause analysis into the high error rate in clinical immunohistochemistry", Appl. Immunohistochem. Mol. Morphol, 27(5), pp.329~338 (2019)[DOI]
  5. V. Cheung, "A comparative study of the characterisation of color cameras by means of neural networks and polynomial transforms", Color Technol, 120(1), pp.19~25 (2004)[DOI]
  6. E. L. Clarke, "Development of a novel tissue-mimicking color calibration slide for digital microscopy", Color. Res. Appl, 43(2), pp.184~197 (2018)[DOI]
  7. T. Cornish, "Clinical application of image analysis in pathology", Adv. Anat. Pathol, 27(4), pp.227~235 (2020)[DOI]
  8. G.D. Finlayson, "White-point preserving color correction", proceeding of The 5th IS&T and SID Color Imaging Conference (1997)
  9. G. D. Finlayson, "Constrained least-squares regression in color spaces", J of Electron Imaging, 6(4), pp.484~493 (1997)
  10. A. Gray, "Quantification of histochemical stains using whole slide imaging: development of a method and demonstration of its usefulness in laboratory quality control", J. Clin. Pathol, 68, pp.192~199 (2015)[DOI]
  11. W. Mokrzycki, "Color difference Delta E – A survey", Mach. Graph. vis, 20(4), pp.383~411 (2011)
  12. C. Ohnishi, "Stain and color calibration and standardization for whole slide image based automated IHC", Lab Invest, 103(3), pp.S100081~ (2023)[DOI]
  13. C. Ohnishi, , Abstract of the Pathology Informatics Summit 2022 (2022)
  14. S. R. Sompuram, "Standardizing immunohistochemistry: a new reference control for detecting staining problem", J. Histochem. Cytochem, 63(9), pp.681~690 (2015)[DOI]
  15. C. M. Van der Loos, "Multiple immunoenzyme staining: methods and visualizations for the observation with spectral imaging", J. Histochem. Cytochem, 56(4), pp.313~328 (2008)[DOI]
  16. A. C. Wolff, "Human epidermal growth factor receptor 2 testing in breast cancer: American society of clinical oncology", college of American pathologists clinical practice guideline focused update, 2018, pp.142(11), 1364~1382
  17. Y. Yagi, "Color standardization and optimization in whole slide imaging", Diagn. Pathol, 6(S1), pp.S15~ (2011)[DOI]

관련 논문AI추천

Image Analysis of HER2 Immunohistochemical Staining of Surgical Breast Cancer Specimens김동민, 박홍식, 이아원, 이연수, 임광일연세대학교의과대학 · Yonsei Medical Journal2019 · 제60권 제2호HER2 status in breast cancer: changes in guidelines and complicating factors for interpretation박소연, 안수민, 우지원, 이경열대한병리학회 · Journal of Pathology and Translational Medicine2020 · 제54권 제1호Automated immunohistochemical assessment ability to evaluate estrogen and progesterone receptor status compared with quantitative reverse transcription-polymerase chain reaction in breast carcinoma patients김애리, 김정렬, 전태성대한병리학회 · Journal of Pathology and Translational Medicine2021 · 제55권 제1호A Nationwide Study on HER2-low Breast Cancer in South Korea: Its Incidence of 2022 Real World Data and the Importance of Immunohistochemical Staining Protocols공경엽, 권귀영, 권선영, 김민종, 김보미, 김아롱, 김완섭, 김은경, 김정렬, 김지연, 김지영, 김헌수, 김희성, 맹영희, 박소연, 배영경, 신나리, 심정윤, 안예리, 유진예, 이소망, 이지신, 이호창, 이희진, 전선영, 조은윤, 최지은, 최현주, 최혜정대한암학회 · Cancer Research and Treatment2024 · 제56권 제4호유방암에서 HER2 유전자 검사를 위한 자동화 은제자리부합법 검사의 유용성: 형광제자리부합법과 면역조직화학염색과의 비교구미진, 박석주, 배영경, 성우정대한병리학회 · Journal of Pathology and Translational Medicine2010 · 제44권 제1호Necessity of In Situ Hybridization Test of Human Epidermal Growth Factor Receptor 2 (HER2) Status in Breast Cancer Patients with Equivocal HER2 Immunohistochemistry ResultsHee Jun Choi, Hyun-June Paik, Isaac Kim, Jai Min Ryu, Jeong Eon Lee, Jonghan Yu, Se Kyung Lee, Seok Jin Nam, Seok Won Kim, Sungmin Park한국유방암학회 · Journal of Breast Disease2018 · 제6권 제1호

이 간행물의 다른 논문 (9건)