본문 바로가기
KERD
논문KCI 등재

구조물의 진동제어를 위한 MR-damper의 최적 제어력 산정

Calculating a MR Damper’s Optimal Capacity for a Control of Structural Vibration

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류토목공학

초록

In the case where a MR-damper is employed for vibration control, it is important to decide on how much control capacity should be assigned to it against structural capacities (strength and load, etc). This paper aims to present a MR-damper's control capacity suitable for the capacities of the structure which needs to be controlled. First, a two span bridge was built equipped with a MR-damper, which constitutes a two-span MR-damper control system. Then, inflicting an earthquake load on the system, a basic experiment was performed for vibration control, and a simulation was also carried out reflecting specific control conditions such as MR-damper and rubber bearing. The comparison of the results against each other proved their validity. Then, in order to calculate an optimal control capacity of the MR-damper, structural capacity was divided into eleven cases in total and simulated. For each case, an additional load of 30 KN was inflicted everytime, thereby increasingly strengthening structural capacity. As a result of the study, it was found that the control capacity of MR-damper of 30 KN was safely secured only with lumped mass of more than 150 KN(case 6). Therefore, it is concluded the MR-damper showed the best performance of control when it exerted its capacity at around 20% of structural capacity.

Abstract

In the case where a MR-damper is employed for vibration control, it is important to decide on how much control capacity should be assigned to it against structural capacities (strength and load, etc). This paper aims to present a MR-damper's control capacity suitable for the capacities of the structure which needs to be controlled. First, a two span bridge was built equipped with a MR-damper, which constitutes a two-span MR-damper control system. Then, inflicting an earthquake load on the system, a basic experiment was performed for vibration control, and a simulation was also carried out reflecting specific control conditions such as MR-damper and rubber bearing. The comparison of the results against each other proved their validity. Then, in order to calculate an optimal control capacity of the MR-damper, structural capacity was divided into eleven cases in total and simulated. For each case, an additional load of 30 KN was inflicted everytime, thereby increasingly strengthening structural capacity. As a result of the study, it was found that the control capacity of MR-damper of 30 KN was safely secured only with lumped mass of more than 150 KN(case 6). Therefore, it is concluded the MR-damper showed the best performance of control when it exerted its capacity at around 20% of structural capacity.

참고문헌 (12)

  1. Anxin Guo, "Experimental and analytical study on pounding reduction of base-isolated highway bridges using MR dampers", Earthquake Engineering and Structural Dtnamics, 38, pp.1307~1333 (2009)
  2. Bogdan Sapiński, "Analysis of Parametric Models of MR Linear Damper", Journal of Theoretical and Applied Mechanics, 41(2), pp.215~240 (2003)
  3. Carlson JD, "Magneto-rheological Fluid Dampers for Semi-active Seismic Control", Proc. 3rd International Conference on Motion and Vibration Control, 3, pp.35~40 (1996)
  4. Dyke SJ, "An Experimental Study of MR Dampers for Seismic Protection", Smart Materials and Structures: Special Issue on Large Civil Structures, 7, pp.693~703 (1998)
  5. Caicedo JM, "Phase II benchmark control problem for seismic response of cablestayed bridges", Journal of Structural Control, 10, pp.137~168 (2003)
  6. Heo G, "Control Performance Evaluation to Avoid Pounding of Bridges", Key Engineering Materials, pp.569~570 (2013)
  7. 허광희, "준능동 진동 제어를 위한 MR 감쇠기의 동적 모델링을 통한 특성분석", 한국구조물진단유지관리공학회 논문집, 17(6), pp.61~69 (2013), 한국구조물진단유지관리공학회[DOI]
  8. Spencer JrBF, "Phenomenological Model of a Magneto rheological Dampe", Journal of Engineering Mechanics. ASCE, 123(3), pp.230~238 (1997)
  9. Sodeyama H, "Dynamic Test and Simulation of Magneto-Rheological Damper", Computer-Aided Civil and Infrastructure Engineering, 18, pp.45~57 (2003)
  10. Sodeyama H, "Development of Large Capacity Semi-Active Seismic Damper Using Magneto-Rheological Fluid", Journal of Vessel Technology. ASME, 126, pp.105~109 (2004)
  11. Iwata N, "Experimental Study on the Effectiveness of a Simple Semi-Active Control Algorithm for Base-Isolated Structures", The 11th Japan Earthquake Engineering Symposium, 326, pp.1761~1766 (2002)
  12. Renzi E, "Testing and modelling a semi‐actively controlled steel frame structure equipped with MR dampers", Structural Control and Health Monitoring, 11, pp.189~221 (2004)

관련 논문AI추천

이 간행물의 다른 논문 (5건)