FEMA P695를 이용한 국내 저층 철골 중간모멘트골조의 반응수정계수 제안
Proposition of Response Modification Factor of Low-rise Steel Intermediate Moment Frame in Korea using FEMA P695
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
In current seismic design code, steel moment frames are classified into ordinary, intermediate, and special moment frames. In the case of special moment frames which have large R-factor, economic design is possible by reducing the design lateral force. However, there is difficulty for practical application due to constraints such as strong column-weak beam requirement. This study evaluated if steel intermediate moment frame could maintain enough seismic capacity when the R-factor is increased from 4.5 to 6. As for the analytical models, steel moment frames of 3 and 5 stories were categorized into four performance groups according to seismic design category. Seismic performances of the frames were evaluated through the procedure based on FEMA P695. FEMA P695 utilizes nonlinear static analysis(pushover analysis) and nonlinear dynamic analysis(incremental dynamic analysis, IDA). In order to reflect the characteristics of Korean steel moment frames on the analytical model, the beam-column connection was modeled as weak panel zone where the collapse of panel zone was indirectly considered by checking its ultimate rotational angle after an analysis is done. The analysis result showed that the performance criteria required by FEMA P695 was satisfied when R-factor increased in all the soil conditions except .
Abstract
In current seismic design code, steel moment frames are classified into ordinary, intermediate, and special moment frames. In the case of special moment frames which have large R-factor, economic design is possible by reducing the design lateral force. However, there is difficulty for practical application due to constraints such as strong column-weak beam requirement. This study evaluated if steel intermediate moment frame could maintain enough seismic capacity when the R-factor is increased from 4.5 to 6. As for the analytical models, steel moment frames of 3 and 5 stories were categorized into four performance groups according to seismic design category. Seismic performances of the frames were evaluated through the procedure based on FEMA P695. FEMA P695 utilizes nonlinear static analysis(pushover analysis) and nonlinear dynamic analysis(incremental dynamic analysis, IDA). In order to reflect the characteristics of Korean steel moment frames on the analytical model, the beam-column connection was modeled as weak panel zone where the collapse of panel zone was indirectly considered by checking its ultimate rotational angle after an analysis is done. The analysis result showed that the performance criteria required by FEMA P695 was satisfied when R-factor increased in all the soil conditions except .
참고문헌 (17)
- Architectural Institute of Korea, "Korean Building Code 2009", ~ (2009)
- Architectural Institute of Korea, "Korean Building Code 2005", ~ (2005)
- International Code Council, "International Building Code 2003", ~ (2003)
- International Code Council, "International Building Code 2000", ~ (2000)
- Kim DH, "Recommendations and Comparison of KBC-S, UBC-97, IBC-2000, and IBC-2003", Journal of Korean Society of Steel Construction, 17(4), pp.31~37 (2005)
- 김태완, "국내 저층 철골 모멘트골조의 내진설계", 한국지진공학회논문집, 15(1), pp.11~18 (2011), 한국지진공학회
- 김태완, "비선형동적해석을 통한 국내 철골 모멘트골조의 내진성능 평가", 한국지진공학회논문집, 16(4), pp.1~8 (2012), 한국지진공학회[DOI]
- State of the Art Report on Performance Prediction and Evaluation of Steel Moment-Frame Buildings, "FEMA", ~, pp.FEMA 355F (2000)
- Quantification of Building Seismic Performance Factors, "FEMA", ~, pp.FEMA P695 (2009)
- 문기훈, "조적조 비내력벽을 가진 기존 학교 구조물의 내진 성능 평가", 한국지진공학회논문집, 16(6), pp.37~46 (2012), 한국지진공학회
- 한상환, "RBS-B 접합부 설계식 개선에 따른 철골모멘트골조 시스템의 내진성능평가", 한국지진공학회논문집, 14(6), pp.75~84 (2010), 한국지진공학회
- 이준호, "FEMA P695를 이용한 격간벽 구조의 내진성능평가", 한국지진공학회논문집, 16(3), pp.43~50 (2012), 한국지진공학회[DOI]
- Mazzoni S, "Open system for earth quake engineering simulation (OpenSees). User Command Language Manual", Pacific Earthquake Engineering Research Center, ~ (2006)
- Lee CH, "Cyclic Seismic Testing of Full-Scale Column-Tree Type Steel Moment Connections", 10(4), pp.629~639 (1998)
- Seismic Demands for Performance Evaluation of Steel Moment Resisting Frame Structures, "Gupta A", ~, pp.John A. Blume Earth quake Engineering Research Center Report No.132 (1999)
- Prestandard and Commentary for the Seismic Rehabilitation of Buildings, "FEMA", ~, pp.FEMA 356 (2000)
- Seismic Performance, Capacity and Reliability of Structures as seen through Incremental Dynamic Analysis, "Vamvatsikos D", ~, pp.John A. Blume Earthquake Engineering Research Center Report No.151 (2005)