Seismic Behavior of Liquid Storage Tanks Using Complex and Simple Analytical Models
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Performance-based seismic evaluation is usually done by considering simplified models for the liquid storage tanks therefore, it is important to validate those simplified models before conducting such evaluation. The purpose of this study is to compare the seismic response results of the FSI (fluid-structure interaction) model and the simplified models for the cylindrical liquid storage tanks and to verify the applicability of the simplified models for estimating failure probability. Seismic analyses were carried out for two types of storage tanks with different aspect ratios (H/D) of 0.45 and 0.86. FSI model represents detailed 3D fluid-structure interaction model and simplified models are modeled as cantilever mass-spring model, frame type mass-spring model and shell type mass-spring model, considering impulsive and convective components. Seismic analyses were performed with modal analysis followed by time history analysis. Analysis results from all the models were verified by comparing with the results calculated by the code and literature. The results from simplified models show good agreement with the ones from detailed FSI model and calculated results from code and literature, confirming that all three types of simplified models are very valid for conducting failure probability analysis of the cylindrical liquid storage tanks.
Abstract
Performance-based seismic evaluation is usually done by considering simplified models for the liquid storage tanks therefore, it is important to validate those simplified models before conducting such evaluation. The purpose of this study is to compare the seismic response results of the FSI (fluid-structure interaction) model and the simplified models for the cylindrical liquid storage tanks and to verify the applicability of the simplified models for estimating failure probability. Seismic analyses were carried out for two types of storage tanks with different aspect ratios (H/D) of 0.45 and 0.86. FSI model represents detailed 3D fluid-structure interaction model and simplified models are modeled as cantilever mass-spring model, frame type mass-spring model and shell type mass-spring model, considering impulsive and convective components. Seismic analyses were performed with modal analysis followed by time history analysis. Analysis results from all the models were verified by comparing with the results calculated by the code and literature. The results from simplified models show good agreement with the ones from detailed FSI model and calculated results from code and literature, confirming that all three types of simplified models are very valid for conducting failure probability analysis of the cylindrical liquid storage tanks.
참고문헌 (24)
- Úradniček J, "An Applied Research of Seismic and Vibration Resistance of the Equipment With Assessment of Seismic and vibration effects", EuroNoise 2015 (2015)
- Uma Chaduvula, "Fluid-Structure-Soil Interaction Effects on Seismic Behaviour of Elevated Water Tanks", Procedia Engineering, 51(12), pp.84~91 (2013), Elsevier BV[DOI]
- Bakalis K, "Surrogate Modeling for the Seismic Performance Assessment of Liquid Storage Tanks", Journal of Structural Engineering, 143(4), pp.4016199~ (2017)[DOI]
- S. Girgin, "The natech events during the 17 August 1999 Kocaeli earthquake: aftermath and lessons learned", Natural Hazards and Earth System Sciences, 11(4), pp.1129~1140 (2011), Copernicus GmbH[DOI]
- A study of the performance of petrolium storage tanks during earthquakes, 1993-1995, "Cooper Thomas W", United States Department of Commerce Technology Administration, National Institute of Standard and Technology, ~ (1995)
- Praveen K. Malhotra, "Simple Procedure for Seismic Analysis of Liquid-Storage Tanks", Structural Engineering International, 10(3), pp.197~201 (2018), Informa UK Limited[DOI]
- Housner GW, "Dynamic pressures on accelerated fluid containers", Bulletin of the Seismological Society of America, 47(1), pp.15~35 (1957)
- Housner GW, "The dynamic behavior of water tanks", Bulletin of Seismological Society of America, 53, pp.381~387 (1963)
- American Concrete Institute, "Seismic design of liquid containing concrete structures", ACI, ~ (2006)
- Guidelines for seismic design of liquid storage tanks, "IITK-GSDMA", Indian Institute of Technology, ~ (2007)
- Malhotra PK, "Uplifting response of unanchored liquidstorage tanks", ASCE Journal of Structural Engineering, 120(12), pp.3525~3547 (1994)
- Bayraktar S, "Effect of the model updating on earthquake behaviour of steel storage tanks", Journal of Construction Steel Research, 66(3), pp.462~469 (2010)
- M.R. Kianoush, "The effect of earthquake frequency content on the seismic behavior of concrete rectangular liquid tanks using the finite element method incorporating soil–structure interaction", Engineering Structures, 33(7), pp.2186~2200 (2011), Elsevier BV[DOI]
- Chopra AK, "Dynamics of Structures" (2000), Prentic-hall
- Canonsburg TD, "ANSYS Mechanical APDL verification manual. Knowledge Creation Diffusion", Utilization, 15317(10), pp.724~746 (2012)
- Benasciutti D, "Seismic analysis of a liquid storage tank used in wine industry:a FEM-based approach", V: International CAE Conference (2014)
- Juan C. Virella, "Fundamental modes of tank-liquid systems under horizontal motions", Engineering Structures, 28(10), pp.1450~1461 (2006), Elsevier BV[DOI]
- Housner GW, "The dynamic behavior of water tanks", Bulletin of Seismological Society of America, 53, pp.381~387 (1963)
- "Eurocode 8. Design of structures for earthquake resistance-part 4. Silos, tanks and pipelines", The European Union Per Regulation 305, 2004 (2011)
- Yi LP, "Modal Analysis on Anchored Tank Considering Shell and Fluid Coupling", Advance Materials Research, 549, pp.903~907 (2012)
- Wilson EL, "Finite elements for the dynamicanalysisof fluid-solid systems", International Journal of Numerical Methods in Engineering, 19, pp.657~668 (1983)
- Kianoush KA, "The effect of earthquake frequency content on the seismic behavior of concrete rectangular liquid tanks using the finite element method in corporating soilstructure-interaction", Engineering Structures, 33(7), pp.2186~2200 (2011)[DOI]
- Vibrational Characteristics and Seismic Analysis of Cylindrical Liquid Storage Tanks, "Tedesco Joshep W.", 433~ (1982)
- Evaluation of seismic safety of buildings-simulated earthquake motions compatible with prescribed response spectra, "Gasparini DA", Massachusettes Institute of Technology, ~, pp.Report No. 2