다중 지진 시나리오를 고려한 원전 격납구조물의 조건부평균 스펙트럼 기반 지진취약도 평가
Seismic Fragility Assessment of NPP Containment Structure based on Conditional Mean Spectra for Multiple Earthquake Scenarios
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
A methodology to assess seismic fragility of a nuclear power plant (NPP) using a conditional mean spectrum is proposed as an alternative to using a uniform hazard response spectrum. Rather than the single-scenario conditional mean spectrum, which is the conventional conditional mean spectrum based on a single scenario, a multi-scenario conditional mean spectrum is proposed for the case in which no single scenario is dominant. The multi-scenario conditional mean spectrum is defined as the weighted average of different conditional mean spectra, each one of which corresponds to an individual scenario. The weighting factors for scenarios are obtained from a deaggregation of seismic hazards. As a validation example, a seismic fragility assessment of an NPP containment structure is performed using a uniform hazard response spectrum and different single-scenario conditional mean spectra and multi-scenario conditional mean spectra. In the example, the number of scenarios primarily influences the median capacity of the evaluated structure. Meanwhile, the control frequency, a key parameter of a conditional mean spectrum, plays an important role in reducing logarithmic standard deviation of the corresponding fragility curves and corresponding high confidence of low probability of failure (HCLPF) capacity.
Abstract
A methodology to assess seismic fragility of a nuclear power plant (NPP) using a conditional mean spectrum is proposed as an alternative to using a uniform hazard response spectrum. Rather than the single-scenario conditional mean spectrum, which is the conventional conditional mean spectrum based on a single scenario, a multi-scenario conditional mean spectrum is proposed for the case in which no single scenario is dominant. The multi-scenario conditional mean spectrum is defined as the weighted average of different conditional mean spectra, each one of which corresponds to an individual scenario. The weighting factors for scenarios are obtained from a deaggregation of seismic hazards. As a validation example, a seismic fragility assessment of an NPP containment structure is performed using a uniform hazard response spectrum and different single-scenario conditional mean spectra and multi-scenario conditional mean spectra. In the example, the number of scenarios primarily influences the median capacity of the evaluated structure. Meanwhile, the control frequency, a key parameter of a conditional mean spectrum, plays an important role in reducing logarithmic standard deviation of the corresponding fragility curves and corresponding high confidence of low probability of failure (HCLPF) capacity.
참고문헌 (21)
- 김민규, "평가용 스펙트럼이 구조물의 지진리스크에 미치는 영향", 한국지진공학회논문집, 13(6), pp.39~46 (2009), 한국지진공학회
- 함대기, "암반 지반의 재해도 스펙트럼에 기반한 토사지반 원전 부지의 등재해도 스펙트럼 평가 기법", 한국지진공학회논문집, 16(3), pp.35~42 (2012), 한국지진공학회[DOI]
- Choi IK, "Probabilistic seismic risk analysis of CANDU containment structure near-fault earthquakes", Korea Atomic Energy Research Institute. Republic of Korea, 238(6), pp.1382~1391 (2008)
- Choi IK, "Inelastic Energy Absorption Factor for the Seismic Probabilistic Risk Assessment of NPP Containment Structure", Earthquake Engineering Society of Korea, 5(5), pp.47~56 (2001)
- Cho SG, "Seismic fragility analyses of nuclear power plant structures based on the recorede earthquake data in Korea", Korea Atomic Energy Research Institute, Republic of Korea, 235(17-19), pp.1867~1874 (2005)
- 조양희, "모드기여도를 고려한 복수모드구조물의 지진취약도분석", 한국지진공학회논문집, 6(4), pp.15~22 (2002), 한국지진공학회
- 최인길, "비선형 지진해석에 의한 PSC 격납건물의 지진취약도 분석", 한국지진공학회논문집, 10(1), pp.63~74 (2006), 한국지진공학회
- Baker JW, "Conditional Mean Spectrum: Tool for Ground-Motion Selection", Journal of Structural Engineering, 137(3), pp.322~331 (2011)
- PEGASOS refinement project: new findings and challenges from a PSHA for Swiss Nuclear Power Plants, Transactions, "Renault P.", SMiRT, ~, pp.Div-IV:Paper ID# 561 (2011)
- Haselton CB, "Response History Analysis for the Design of New Buildings in the NEHRP provisions and ASCE", SEI 7 Standard: part Ⅰ – overviwe and Specification of Ground Motions, 2017, pp.33(2), 373~395
- Haselton CB, "Response History Analysis for the Design of New Buildings in the NEHRP Provisions and ASCD", SEI 7 Standard:Part Ⅱ-Structural Aanlysis Procedures and Acceptance Criteria, 2017, pp.33(2), 397~417
- Zimmerman RB, "Response History Analysis for the Design of New Buildings in the NEHRP Provisions and ASCD", SEI 7 Standard : Part Ⅲ - Example Applications Illustrating the Recommended Methodology, 2017, pp.33(2), 419~447
- Jarrett JA, "Response-History Analysis for the Design of New Buildings in the NEHRP Provisions and ASCE", SEI 7 Sthandard: Part Ⅳ-A Study of Assumptions, 2017, pp.33(2), 449~468
- "ASCE", SEI 7-16. Minimum Design Loads and Associated Creteria for Buildings and other Structures, 2017
- Korea Electrical Power Corporation, Korea Hydro & Nuclear Power Co., LTD, "APR1400 DESIGN CONTROL DOCUMENT TIER2. APR1400-K-X-FS-14002-NP REVISION 0. Republic of Korea", ~ (2014)
- "Regulatory guide 1.208. a perfomance-based approcach to define the site-specific earthquake ground motion", U.S. Nuclear Regulatory Commission, ~ (2007)
- Atkinson GM, "Earthquake Ground-Motion Prediction Equations for Eastern North America", Bulletin of the Seismological Society of America, 96(6), pp.2181~2205 (2006)
- Jayaram N, "Computationally Efficient Ground-Motion Selection Algorithm for Matching a Target Response Spectrum Mean and Variance", Earthquake Spectra, 27(3), pp.797~815 (2011)
- Methodology for developing seismic fragilities, "Reed JW", Electric Power Research Institute, ~, pp.EPRI TR-103959 (1994)
- Ogaki Y, "Shear strength tests of prestressed concrete containment vessels", SMiRT-6. 1981;13(22)J4, 1981
- ASME, "Boiler and Pressure Vessel Code, Division 2, Code for Concrete Containments", ~ (2015)