The Gyeongju and Pohang earthquakes caused damages to many cultural properties; particularly, stone pagoda structures were significantly damaged among masonry cultural properties. To preserve these structures, it is necessary to understand their dynamic behavior characteristics under earthquakes. Analyses on such areas as deformation, frequency, maximum acceleration, permanent displacement, sliding, and rocking have to be performed. Although many analytical studies have already been conducted, dynamic behavior studies based on experiments are insufficient. Therefore, this study analyzed dynamic behavior characteristics by performing a shaking table experiment on a three-story stone pagoda structure at the Cheollongsa temple site damaged by the Gyeongju earthquake. As a result of the experiment, the displacements of stylobates did not occur significantly, but the tower body parts rotated. In particular, the rotation of the 1F main body stone was relatively larger than that of the other chief body stones because the 1F main body stone is relatively more slender than the other parts. In addition, the decorative top was identified as the component most vulnerable to sliding. This study found that the 1F main body stone is vulnerable to rocking, and the parts located on the upper part are more vulnerable to sliding.
Abstract
The Gyeongju and Pohang earthquakes caused damages to many cultural properties; particularly, stone pagoda structures were significantly damaged among masonry cultural properties. To preserve these structures, it is necessary to understand their dynamic behavior characteristics under earthquakes. Analyses on such areas as deformation, frequency, maximum acceleration, permanent displacement, sliding, and rocking have to be performed. Although many analytical studies have already been conducted, dynamic behavior studies based on experiments are insufficient. Therefore, this study analyzed dynamic behavior characteristics by performing a shaking table experiment on a three-story stone pagoda structure at the Cheollongsa temple site damaged by the Gyeongju earthquake. As a result of the experiment, the displacements of stylobates did not occur significantly, but the tower body parts rotated. In particular, the rotation of the 1F main body stone was relatively larger than that of the other chief body stones because the 1F main body stone is relatively more slender than the other parts. In addition, the decorative top was identified as the component most vulnerable to sliding. This study found that the 1F main body stone is vulnerable to rocking, and the parts located on the upper part are more vulnerable to sliding.
참고문헌 (14)
- Kim JK, "Dynamic Test of a Full Scale Model of Five-Story Stone Pagoda of Sang-Gye-Sa", Journal of Earthquake Engineering Society of Korea, 5, pp.51~66 (2001)
- Kim JK, "Shaking Table Test of the Model of Five-story Stone Pagoda of Sang-Gye-Sa Mounted on Base Isolation Systems", Proceedings of Earthquake Engineering Society of Korea Conference, 1, pp.331~338 (2001)
- 노현섭, "2층 비보강 조적조 건축물의 지진응답에 대한 실험 연구", 대한건축학회논문집 구조계, 18(4), pp.59~66 (2002), 대한건축학회
- Gavrilovic P, "Development of a Methodology for seismic strengthening of Byzantine churches", Transactions on the Built Environment, 15 (1995)
- Gavrilovic P, "Seismic Isolation: A New Approach to Earthquake Protection of Historic Monuments", International Seminar on Structural Analysis of Historical Constructions;Possibilities of Numerical and Experimental Techniques (2005)
- Krestevska L, "Structural Analysis of Historic Construction", pp.383~391 (2008)
- Hanazato T, "Shaking Table Test of Model House of Brick Masonry for Seismic Construction", Proceedings of 14th World Conference of Earthquake Engineering (14WCEE) (2008)
- National Research Institute of Cultural Heritage, "Stone pagoda of Gyeongsangbuk-do Ⅲ", NRICH, 149~ (2009)
- 홍석일, "석탑의 불연속면 거칠기에 따른 구조거동평가", 대한건축학회논문집 구조계, 27(10), pp.63~70 (2011), 대한건축학회
- 황재승, "진동대를 이용한 역사적 지진 작용 전통목구조(봉정사 대웅전)의 동적 특성", 대한건축학회논문집 구조계, 31(11), pp.37~46 (2015), 대한건축학회[DOI]
- "KDS 41 17 00. Seismic Building Design Code", Ministry of Land, Infrastructure and Transport, ~ (2019)
- "National Earthquake Comprehensive Information System(NECIS)"[URL]
- "Strong motion database"[URL]