This study proposed a seismic reinforcement of RC columns with non-seismic details, a fiber reinforcement method of aramid sheets and MLCP (high elasticity aromatic polyester fiber material) with different characteristics, and 4 full-size column specimens and conducted experiments. The results show that a non-seismic specimen (RC-Orig) rapidly lost its load-bearing capacity after reaching the maximum load, and shear failure occurred. The RC column reinforced with three types of aramid did not show an apparent increase in strength compared to the unreinforced specimen but showed a ductile behavior supporting the load while receiving a lateral displacement at least 1.57 to 1.95 times higher than the unreinforced specimen. The fracture mode of the specimen, according to the application of lateral load, also changed from shear to ductile fracture through aramid-based reinforcement. In addition, when examining the energy dissipation ability of the reinforced specimens, a ductile behavior dissipating seismic energy performed 4 times greater and more stably than the existing specimens.
Abstract
This study proposed a seismic reinforcement of RC columns with non-seismic details, a fiber reinforcement method of aramid sheets and MLCP (high elasticity aromatic polyester fiber material) with different characteristics, and 4 full-size column specimens and conducted experiments. The results show that a non-seismic specimen (RC-Orig) rapidly lost its load-bearing capacity after reaching the maximum load, and shear failure occurred. The RC column reinforced with three types of aramid did not show an apparent increase in strength compared to the unreinforced specimen but showed a ductile behavior supporting the load while receiving a lateral displacement at least 1.57 to 1.95 times higher than the unreinforced specimen. The fracture mode of the specimen, according to the application of lateral load, also changed from shear to ductile fracture through aramid-based reinforcement. In addition, when examining the energy dissipation ability of the reinforced specimens, a ductile behavior dissipating seismic energy performed 4 times greater and more stably than the existing specimens.
참고문헌 (14)
- Site Inspection and Damage Investigation of Buildings by Earthquakes in Gyeongju and Pohang, "Architectural institute of Korea", ~ (2018)
- The Road to Earthquake Resilience in San Francisco, Com-munity Action Plan for Seismic Safety, , Applied Technology Council, ~, pp.ATC-52-2 Report (2010)
- 엄태성, "2017 포항지진에 의한 필로티형 내력벽건물의 구조손상 분석", 한국지진공학회논문집, 23(1), pp.9~18 (2019), 한국지진공학회[DOI]
- 김태완, "2017년 포항지진으로 피해를 입은 국내 필로티형 건물의 지진 거동", 한국지진공학회논문집, 22(3), pp.161~168 (2018), 한국지진공학회[DOI]
- MOE, "Guideline for Seismic Evaluation and Rehabilitation of Existing School Buildings", Ministry of Education, ~ (2021)
- Lee HH, "A experimental study on the capacity evaluation of the shear-strengthened RC column with aramid fiber sheet", Journal of the Architectural Institute of Korea, Structure & Construction, 15(6), pp.29~36 (1999)
- Choi JJ, "FRP Seismic Reinforcement Method of Pilotty Structures Column Expected to be Damaged by Pohang Earthquake", Magazine of the Korean Society Advanced Compostite Structures, 9(3), pp.14~21 (2018)
- Hoang DV, "Experimental investigation of RC corner columns with varying seismic details under different lateral and vertical loading", Master, pp.2014
- Korean Standards Association, "KS F 2403 Standard test method for making concrete specimens", Korean Standards Association, ~ (2019)
- Korean Standards Association, "KS F 2405. Standard Test Method for Compressive Strength of Concrete", Korean Standards Association, ~ (2017)
- Korean Standards Association, "KS B 0802. Method of Tensile Test for Metallic Materials", Korean Standards Association, ~ (2018)
- "FEMA 461. Interim testing protocols for determining the seismic performance characteristics of structural and nonstructural components", ~ (2007)
- "ACI 440.2R-08. Guide for design and construction of externally bonded FRP systems for strengthening concrete structures", ~ (2008)
- Ye L, "Shear strength of reinforced concrete columns strengthened with carbon-fiber-reinforced plastic sheet", Journal of Structural Engineering, 128(12), pp.1527~1534 (2002)