배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험(Ⅱ) - 문비 안에서 밖으로의 흐름 -
Model Tests Study on Flow-induced Vibration of Tainter Gate in Estuary Sulices(Ⅱ)- Flow from the Gate Inside to the Gate Outside -
0
조회
0
다운로드
2
인용
0
참고문헌
초록
Abstract
A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66 m in width, 0.5 m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. In the flow from the gate inside to the gate outside, the amplitudes of the vibration are measured under the different gate opening and downstream water level conditions. Also revised gate models with 20 mm bottom width are tested under the different gate openings and water levels. The results are analyzed to study the characteristics of the Tainter gate vibration in the sea ward flow.These test results are assessed in comparison with the results in the lake ward flow, as a result, presents the dynamic characteristics of the Tainter gate and a basic data for the guide manuals of gate management.
참고문헌 (6)
- "NISAⅡ User's Manual", pp.1~50 (1999), Center for Engineering and Computer Technology
- "Flow-induced Gate Vibrations. Prevention of Self-excitation", publ.(164), pp.1162~ (1974)
- "Study on Self-excited Vibration of Radial Gate in Estuary Sulices due to Bottom Shape by Hydraulic Model Tests", 3(1), pp.10~19 (1996)
- "Model Tests Study on Self-excited Vibration of Tainter Gate", 16(Ⅰ-2), pp.187~194 (1996)
- "Gate Vibrations due to Unstable Flow Separation Journal of Hydraulics Engineering 116", pp.342361~
- "Vortex-excited Vibrations of Underflow Gates Journal of Hydraulic Research 24", pp.133151~