본문 바로가기
KERD
논문

비강우시 도시 합류식 하수도의 오염부하 산정을 위한 최적관측시간 산정연구

Optimum Flow and Pollution Load Monitoring Time of Combined Sewers of Urban Watersheds during Dry Weather

1

조회

0

다운로드

1

인용

0

참고문헌

주제분류농학

초록

Abstract

Flow and pollution load were monitored at 2 combined sewer outlets (C-1 and C-2) of urban watersheds during dry weather from September, 2004 to April, 2006 for 20 months. The objectives were to investigate the diurnal variation of flow and pollutant load and to find the proper sampling time that could measure representative flow and pollutant load. Pollution load closed to the average daily load at C-1 could be measured at 00:00 hour and by the mean of 15:00 and 18:00 hour measures, and 15:00 and 21:00 hour measures, respectively. In addition at C-2, it was 21:00 hour and the mean of 15:00 and 18:00 hour measures. This study concluded that arbitrary sampling of flow and water quality could cause large errors in the estimation of urban pollution load and recommended that urban combined sewers should be monitored when flow and water quality showed daily average and concentration.

참고문헌 (14)

  1. 안영호, "도시 하수관거시스템에서의 I", I 및 CSOs 발생특성, 2004, pp.24(4b), 381~390[DOI]
  2. APHA, "Standard methods for the examination of water and wastewater (19th)" (1995), American Pubilc Health Association
  3. Bang, K. W., "An experimental study on sewage discharge characteristics of apartment area (Ⅱ): Part of periodicity analysis", Journal of Korean Society on Water Quality, 14(2), pp.145~152 (1998)
  4. Cho, J. Y., "Management plans for combined sewer overflows", Journal of Nakdonggang Environmental Research Institute, 7(1), pp.253~263 (2002)
  5. 조만재, "합류식 하수관거내 퇴적물에 의한 오염물질 발생특성", 한국물환경학회지, 17(3)통권 : 3, pp.407~415 (2001), 한국물환경학회
  6. Choi, M. S., "An experimental study on sewage discharge characteristics of apartment area (Ⅰ): Part of unit loading of pollutants", Journal of Korean Society on Water Quality, 14(2), pp.137~144 (1998)
  7. 강용태, "도시지역 가정하수의 오염부하량을 이용한 비점오염원유출특성에 관한 연구", 한국수처리학회지, 14(2), pp.57~66 (2006), 한국수처리학회
  8. 김정곤, "대전광역시 소유역에서 합류식 하수관거 월류수(CSOs)의 배출특성 모델링", 대한환경공학회지, 28(6), pp.654~660 (2006), 대한환경공학회
  9. Kim, W. J,, "Characterization of diurnal load variation of combined sewer wastewater", Proceedings of 2008 Spring Conference of Korean Society on Water Quality and Korea Society of Water and Wastewater, 197~198 (2008)
  10. 이혜숙, "합류식 하수관거 월류수 유입 기간 동안에 나타나는 청계천 수질 변화 모델 연구(050804-051229)", 대한환경공학회지, 27(12), pp.1340~1346 (2005), 대한환경공학회
  11. Ministry of Environment, "Official test methods for water pollution", ~ (2001)
  12. Park, N. Y., "Status of combined sewer overflow (CSO) treatment facilities", Journal of Korea Society of Water and Wastewater, 17(2), pp.204~210 (2003)
  13. Lyman,R.O., "An introduction to statistical methods and data analysis 4th edition. Belmont" (1992), Duxbury Press
  14. Shin, E. B., "Pollutant settling characteristics of combined sewer overflows in urban area", Journal of Korean Society on Water Quality, 14(4), pp.425~432 (1998)

이 간행물의 다른 논문 (8건)