Many parts of problems in livestock industry today are associated with organic dust. Endotoxin and toxic gasses on the surface of dust and dust itself can cause aesthetic displeasure and respiratory disease. It also reduces livestock productivity by suppressing immunity of animals and carrying microbes causing animal disease. However, dust level of cattle farm was rarely reported in Korea, and regulation for cattle farm worker does not exist. In this paper, dust concentration and environmental condition were regularly monitored in a commercial Korean native cattle farm. The measurement was conducted according to location and working activities. From the measurement, distribution of dust concentration was affected by wind environment, as the result of natural ventilation. TMR mixer was a major source of dust in target cattle house. The maximum inhalable dust concentration was 637.8 times higher than exposure limit as feed dropped into the TMR mixer. It was expected that dust generation could be affected by particle size and drop height of feed. This study suggests potential risk of dust in cattle farm, and necessity for latter study. Effect of aerodynamic condition and TMR processing should be investigated for dust reduction study.

Abstract

Many parts of problems in livestock industry today are associated with organic dust. Endotoxin and toxic gasses on the surface of dust and dust itself can cause aesthetic displeasure and respiratory disease. It also reduces livestock productivity by suppressing immunity of animals and carrying microbes causing animal disease. However, dust level of cattle farm was rarely reported in Korea, and regulation for cattle farm worker does not exist. In this paper, dust concentration and environmental condition were regularly monitored in a commercial Korean native cattle farm. The measurement was conducted according to location and working activities. From the measurement, distribution of dust concentration was affected by wind environment, as the result of natural ventilation. TMR mixer was a major source of dust in target cattle house. The maximum inhalable dust concentration was 637.8 times higher than exposure limit as feed dropped into the TMR mixer. It was expected that dust generation could be affected by particle size and drop height of feed. This study suggests potential risk of dust in cattle farm, and necessity for latter study. Effect of aerodynamic condition and TMR processing should be investigated for dust reduction study.

참고문헌 (19)

  1. Arteaga, V. E., "Occupational Exposure to Endotoxin in PM2.5 and Pre-and Post-Shift Lung Function in California Dairy Workers", Journal of Environmental Protection, 6(5), pp.552~ (2015)
  2. Böhlandt, A., "Cow hair allergen concentrations in dairy farms with automatic and conventional milking systems: from stable to bedroom", International Journal of Hygiene and Environmental Health, 219(1), pp.79~87 (2016)
  3. CIGR, "Aerial environment in animal housing - concentrations in and emissions from farm buildings" (1994), CEMAGREF
  4. D’Ann, L. W., "Cow allergen (Bos d2) and endotoxin concentrations are higher in the settled dust of homes proximate to industrial-scale dairy operations", Journal of Exposure Science and Environmental Epidemiology, 26(1), pp.42~47 (2016)
  5. Donham, K. J., "Dose-Response Relationships Between Occupational Aerosol Exposures and Cross-Shift Declines of Lung Function in Poultry Workers:: Recommendations for Exposure Limits", Journal of Occupational and Environmental Medicine, 42(3), pp.260~269 (2000)
  6. Donham, K. J., "Respiratory dysfunction in swine production facility workers: Dose-response relationships of environmental exposures and pulmonary function", American Journal of Industrial Medicine, 27(3), pp.405~418 (1995)
  7. 하태환, "공기 중 바이러스 포집 장비의 효율성 평가", 한국농공학회논문집, 54(1), pp.63~72 (2012), 한국농공학회
  8. 조예슬, "윈치커튼식 계사의 시기 및 작업자 출입에 따른 분진 발생 농도 측정 연구", 한국농공학회논문집, 57(6), pp.35~46 (2015), 한국농공학회[DOI]
  9. Kwon, K. S., "Identification of key factors for dust generation in a nursery pig house and evaluation of dust reduction efficiency using a CFD technique", Biosystems Engineering, 151, pp.28~52 (2016)
  10. 권경석, "비육돈사 작업 종사자의 호흡기 관련 공기 중 분진 농도 측정 및 분석", 한국농공학회논문집, 55(5), pp.25~35 (2013), 한국농공학회
  11. 권경석, "강제환기식 계사의 공기 중 분진 농도 측정 및 바닥재로부터의 분진 발생량 분석", 한국농공학회논문집, 56(6), pp.31~43 (2014), 한국농공학회
  12. Lee, J., "Prevalence of Asthma and Organic Dust Exposure among Farmers", Master, pp.2016
  13. Agriculture, Food and Rural Affairs Statistics Yearbook, "MAFRA", Ministry of Agriculture, Food and Rural Affairs, ~ (2016)
  14. 박관용, "유우사 내부 위치 및 작업 형태에 따른 분진 모니터링 및 분석", 한국농공학회논문집, 59(3), pp.71~81 (2017), 한국농공학회[DOI]
  15. Park, J.-H., "The condition for air-borne transmission of foot-and-mouth diease", Korean Journal of Veterinary Public Health, 32(3), pp.205~212 (2008)
  16. Rylander, R., "Effects of exposure to dust in swine confinement buildings—a working group report", Scandinavian journal of work, environment & health, pp.309~312 (1989)
  17. Takai, H., "Concentrations and Emissions of Airborne Dust in Livestock Buildings in Northern Europe", Journal of Agricultural Engineering Research, 70(1), pp.59~77 (1998)
  18. Appendix J to Part 50 – Reference Method for the Determination of Particulate Matter as PM10 in the Atmosphere, "US EPA", ~ (2012)
  19. Zucker, B. A., "Airborne Gram-Negative Bacterial Flora in Animal Houses", Journal of Veterinary Medicine, Series B, 47(1), pp.37~46 (2000)

관련 논문AI추천

이 간행물의 다른 논문 (9건)