Factors Affecting Contrast Sensitivity in Intermittent Exotropia
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: To determine whether contrast sensitivity (CS) can represent photophobia in intermittent exotropia (IXT) by comparingthe CS test with and without glare stimulus, and to analyze the factors of IXT affecting CS. Methods: We retrospectively reviewed the medical records of 107 patients with basic-type IXT. We compared CS undermesopic and photopic conditions, with and without glare. We compared the difference in CS before and after glare (ΔCS) betweenmesopic and photopic conditions, and compared CS with glare between patients with and without photophobia. Thecorrelations between the clinical features of IXT and CS were analyzed. Results: There was no significant reduction in CS at all spatial frequencies by glare stimulus. ΔCS was greater at high spatialfrequencies under photopic conditions than under mesopic conditions. The group with subjective photophobia showed lowerCS at 10.2 cpd under mesopic conditions with glare. CS showed a negative correlation with stereopsis under both mesopicand photopic conditions, and a positive correlation with fusional ability at low and intermediate spatial frequencies undermesopic conditions. ΔCS was smaller at intermediate spatial frequencies with better fusional ability, greater at high spatialfrequencies with photophobia, and greater at intermediate spatial frequencies with a higher frequency of exotropia. Conclusions: The CS test could not represent photophobia in IXT. However, CS tended to decrease with glare stimulus, andCS under mesopic conditions with glare was worse when accompanied by photophobia. Moreover, a poorer degree of stereopsiswas associated with lower CS, and better fusional ability was associated with higher CS under mesopic conditions. Therefore, the CS test can be considered helpful in evaluating sensory function in IXT.
Abstract
Purpose: To determine whether contrast sensitivity (CS) can represent photophobia in intermittent exotropia (IXT) by comparingthe CS test with and without glare stimulus, and to analyze the factors of IXT affecting CS. Methods: We retrospectively reviewed the medical records of 107 patients with basic-type IXT. We compared CS undermesopic and photopic conditions, with and without glare. We compared the difference in CS before and after glare (ΔCS) betweenmesopic and photopic conditions, and compared CS with glare between patients with and without photophobia. Thecorrelations between the clinical features of IXT and CS were analyzed. Results: There was no significant reduction in CS at all spatial frequencies by glare stimulus. ΔCS was greater at high spatialfrequencies under photopic conditions than under mesopic conditions. The group with subjective photophobia showed lowerCS at 10.2 cpd under mesopic conditions with glare. CS showed a negative correlation with stereopsis under both mesopicand photopic conditions, and a positive correlation with fusional ability at low and intermediate spatial frequencies undermesopic conditions. ΔCS was smaller at intermediate spatial frequencies with better fusional ability, greater at high spatialfrequencies with photophobia, and greater at intermediate spatial frequencies with a higher frequency of exotropia. Conclusions: The CS test could not represent photophobia in IXT. However, CS tended to decrease with glare stimulus, andCS under mesopic conditions with glare was worse when accompanied by photophobia. Moreover, a poorer degree of stereopsiswas associated with lower CS, and better fusional ability was associated with higher CS under mesopic conditions. Therefore, the CS test can be considered helpful in evaluating sensory function in IXT.
참고문헌 (14)
- Wang FM, "Monocular eye closure in intermittent exotropia", Arch Ophthalmol, 106, pp.941~942 (1988)
- Oh SY, "The clinical characteristics of intermittent exotropia and their relationship", J Korean Ophthalmol Soc, 39, pp.2797~2802 (1998)
- Manley DR, "Classification of the exodeviations", Symposium on horizontal ocular deviations, pp.128~ (1971), Mosby
- Chung ST, "Comparing the shape of contrast sensitivity functions for normal and low vision", Invest Ophthalmol Vis Sci, 57, pp.198~207 (2016)
- Pang Y, "Contrast sensitivity of amblyopic eyes in children with myopic anisometropia", Clin Exp Optom, 102, pp.57~62 (2019)
- Lew H, "Binocular photophobia after surgical treatment in intermittent exotropia", Optom Vis Sci, 84, pp.1101~1103 (2007)
- Chung SA, "Photophobia measurement in intermittent exotropia using the contrast sensitivity test", Graefes Arch Clin Exp Ophthalmol, 251, pp.1405~1411 (2013)
- Kanazawa M, "Relationship between absorptive lenses and contrast sensitivity in healthy young subjects with glare under photopic-and mesopic-vision conditions", Opt Rev, 20, pp.282~287 (2013)
- Savini G, "Precision and normative values of a new computerized chart for contrast sensitivity testing", Sci Rep, 9, pp.16537~ (2019)
- Kim HR, "Comparison of contrast sensitivity based on the surgical results for intermittent exotropia", Int J Ophthalmol, 12, pp.1725~1730 (2019)
- Cheng A, "The role of the magnocellular pathway in serial deployment of visual attention", Eur J Neurosci, 20, pp.2188~2192 (2004)
- Livingstone MS, "Psychophysical evidence for separate channels for the perception of form, color, movement, and depth", J Neurosci, 7, pp.3416~3468 (1987)
- 권정민, "Subnormal Binocular Contrast Sensitivity Summation in Patients with Intermittent Exotropia", Journal of Korean Medical Science, 33(32), pp.1~9 (2018), 대한의학회
- Oh BL, "Squinting and photophobia in intermittent exotropia", Optom Vis Sci, 91, pp.533~539 (2014)
