Purpose: To compare the success rates, complications, and visual outcomes between silicone Ahmed glaucoma valve (AGV) implantation with 96 mm2 (FP8) or 184 mm2 (FP7) surface areas. Methods: This study is a retrospective review of the records from 132 adult patients (134 eyes) that underwent silicone AGV implant surgery. Among them, the outcomes of 24 eyes from 24 patients with refractory glaucoma who underwent FP8 AGV implantation were compared with 76 eyes from 76 patients who underwent FP7AGV implantation. Preoperative and postoperative data, including intraocular pressure (IOP), visual acuity,number of medications, and complications were compared between the 2 groups. Results: There were no significant differences in baseline characteristics between the 2 groups (p > 0.05). The postoperative visual acuity of the patients in the FP8 group was better than that of the patients in the FP7group in some early postoperative periods (p < 0.05); however, after 10 postoperative months, visual acuity was not significantly different through the 3-year follow-up period (p > 0.05). Postoperative IOP was not significantly different between the 2 groups (p > 0.05) except for IOP on postoperative day 1 (11.42 mmHg for the FP7 group and 7.42 mmHg for the FP8 group; p = 0.031). There was no statistical difference in success rates,final IOP, number of medications, or complication rates between the 2 groups (p > 0.05). Conclusions: The FP7 and FP8 AGV implants showed no difference in terms of vision preservation, IOP reduction,and number of glaucoma medications required.

Abstract

Purpose: To compare the success rates, complications, and visual outcomes between silicone Ahmed glaucoma valve (AGV) implantation with 96 mm2 (FP8) or 184 mm2 (FP7) surface areas. Methods: This study is a retrospective review of the records from 132 adult patients (134 eyes) that underwent silicone AGV implant surgery. Among them, the outcomes of 24 eyes from 24 patients with refractory glaucoma who underwent FP8 AGV implantation were compared with 76 eyes from 76 patients who underwent FP7AGV implantation. Preoperative and postoperative data, including intraocular pressure (IOP), visual acuity,number of medications, and complications were compared between the 2 groups. Results: There were no significant differences in baseline characteristics between the 2 groups (p > 0.05). The postoperative visual acuity of the patients in the FP8 group was better than that of the patients in the FP7group in some early postoperative periods (p < 0.05); however, after 10 postoperative months, visual acuity was not significantly different through the 3-year follow-up period (p > 0.05). Postoperative IOP was not significantly different between the 2 groups (p > 0.05) except for IOP on postoperative day 1 (11.42 mmHg for the FP7 group and 7.42 mmHg for the FP8 group; p = 0.031). There was no statistical difference in success rates,final IOP, number of medications, or complication rates between the 2 groups (p > 0.05). Conclusions: The FP7 and FP8 AGV implants showed no difference in terms of vision preservation, IOP reduction,and number of glaucoma medications required.

참고문헌 (24)

  1. Quigley HA, "The number of people with glaucoma worldwide in 2010 and 2020", Br J Ophthalmol, 90, pp.262~267 (2006)
  2. Allen RC, "Filtration surgery in the treatment of neovascular glaucoma", Ophthalmology, 89, pp.1181~1187 (1982)
  3. Heuer DK, "Trabeculectomy in aphakic eyes", Ophthalmology, 91, pp.1045~1051 (1984)
  4. Syed HM, "Baerveldt-350 implant versus Ahmed valve for refractory glaucoma : a case-controlled comparison", J Glaucoma, 13, pp.38~45 (2004)
  5. Taglia DP, "Comparison of the Ahmed glaucoma valve, the Krupin eye valve with disk, and the double-plate Molteno implant", J Glaucoma, 11, pp.347~353 (2002)
  6. Hu CH, "Ahmed glaucoma valve implant in refractory glaucoma", J Korean Ophthalmol Soc, 38, pp.259~266 (1997)
  7. Zorab A, "The reduction of tension in chronic glaucoma", Ophthalmoscope, 10, pp.258~261 (1912)
  8. Souza C, "Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas", Am J Ophthalmol, 144, pp.893~900 (2007)
  9. Coleman AL, "Initial clinical experience with the Ahmed glaucoma valve implant", Am J Ophthalmol, 120, pp.23~31 (1995)
  10. Kaya M, "Long-term success of ahmed glaucoma valve in refractory glaucoma", Int J Ophthalmol, 5, pp.108~112 (2012)
  11. Hinkle DM, "A comparison of the polypropylene plate Ahmed glaucoma valve to the silicone plate Ahmed glaucoma flexible valve", Eur J Ophthalmol, 17, pp.696~701 (2007)
  12. Schwartz KS, "Glaucoma drainage implants : a critical comparison of types", Curr Opin Ophthalmol, 17, pp.181~189 (2006)
  13. Heuer DK, "Which is better? One or two? A randomized clinical trial of single-plate versus double-plate Molteno implantation for glaucomas in aphakia and pseudophakia", Ophthalmology, 99, pp.1512~1519 (1992)
  14. Seah SK, "Intermediate-term outcome of Baerveldt glaucoma implants in Asian eyes", Ophthalmology, 110, pp.888~894 (2003)
  15. Lloyd MA, "Intermediate-term results of a randomized clinical trial of the 350-versus the 500-mm2 Baerveldt implant", Ophthalmology, 101, pp.1456~1463 (1994)
  16. Britt MT, "Randomized clinical trial of the 350-mm2 versus the 500-mm2 Baerveldt implant: longer term results: is bigger better?", Ophthalmology, 106, pp.2312~2318 (1999)
  17. Hong CH, "Glaucoma drainage devices : a systematic literature review and current controversies", Surv Ophthalmol, 50, pp.48~60 (2005)
  18. 강상혁, "Ahmed 녹내장 장치 수술시 pericardial membrane(Precludeⓡ)으로 표면적을 확장시킨 효과", 대한안과학회지, 43(11), pp.18~2201 (2002), 대한안과학회
  19. Smith SL, "Early clinical experience with the Baerveldt 350-mm2 glaucoma implant and associated extraocular muscle imbalance", Ophthalmology, 100, pp.914~918 (1993)
  20. Kook MS, "Combined pars plana vitrectomy and Ahmed implantation for refractory glaucoma", J Korean Ophthalmol Soc, 39, pp.559~565 (1998)
  21. Ishida K, "Comparison of polypropylene and silicone Ahmed glaucoma valves", Ophthalmology, 113, pp.1320~1326 (2006)
  22. Mokbel TH, "Flexible Ahmed valve for selected cases of refractory glaucoma", Eur J Ophthalmol, 22, pp.83~89 (2012)
  23. 오상준, "아메드 밸브의 표면적에 따른 단기 수술결과 : 96 ㎟와 184 ㎟", 대한안과학회지, 45(11), pp.14~14 (2004), 대한안과학회
  24. Law RW, "Modification of an adultsized Ahmed glaucoma valve for a small globe", Jpn J Ophthalmol, 50, pp.67~68 (2006)

관련 논문AI추천

이 간행물의 다른 논문 (14건)