본문 바로가기
KERD
논문KCI 등재

Encapsulated bleb excision with collagen matrix implantation following failed Ahmed glaucoma valve implantation

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To investigate the clinical features and surgical outcomes of encapsulated bleb excision with collagenmatrix implantation performed in patients with failed Ahmed glaucoma valve (AGV) implantation. Methods: Eighteen eyes of 18 patients underwent encapsulated bleb excision and collagen matrix implantation. Patients were divided into two groups by reference to intraocular pressure (IOP) after preoperativeocular massage: group 1, patients who exhibited substantial IOP reductions; and group 2, patients who didnot show substantial changes in IOP. Needling was conducted in group 2. The clinical features of the twogroups were compared, including IOP changes after ocular massage and needling, AGV status, and surgicaloutcomes 6 months after surgery. Results: The mean preoperative IOP among the 18 patients was 30.6 ± 5.7 mmHg. After ocular massage, theIOPs decreased by 22 and 26 mmHg in the two patients in group 1 and the 16 patients in group 2 showed amean IOP reduction of 1.6 ± 2.2 mmHg (p = 0.013). IOPs decreased after needling in group 2 (range, 6 to 30mmHg; p < 0.001). Fibrovascular tissue ingrowth into the AGV was observed in the two patients in group 1and the same ingrowth was observed in 10 of the 16 patients in group 2. Six months after surgery the meanIOP among the 18 patients decreased significantly (19.1 ± 3.2 mmHg, p < 0.001). There was no significant differencein the mean postoperative IOP at 6 months between group 1 (14.0 ± 2.8 mmHg) and group 2 (19.8 ± 2.6mmHg, p = 0.052). Conclusions: Encapsulated bleb excision with collagen matrix implantation resulted in a significant IOP-loweringeffect 6 months after surgery. Fibrovascular ingrowth into the AGV was common but did not seem to bea major cause of AGV implantation failure.

Abstract

Purpose: To investigate the clinical features and surgical outcomes of encapsulated bleb excision with collagenmatrix implantation performed in patients with failed Ahmed glaucoma valve (AGV) implantation. Methods: Eighteen eyes of 18 patients underwent encapsulated bleb excision and collagen matrix implantation. Patients were divided into two groups by reference to intraocular pressure (IOP) after preoperativeocular massage: group 1, patients who exhibited substantial IOP reductions; and group 2, patients who didnot show substantial changes in IOP. Needling was conducted in group 2. The clinical features of the twogroups were compared, including IOP changes after ocular massage and needling, AGV status, and surgicaloutcomes 6 months after surgery. Results: The mean preoperative IOP among the 18 patients was 30.6 ± 5.7 mmHg. After ocular massage, theIOPs decreased by 22 and 26 mmHg in the two patients in group 1 and the 16 patients in group 2 showed amean IOP reduction of 1.6 ± 2.2 mmHg (p = 0.013). IOPs decreased after needling in group 2 (range, 6 to 30mmHg; p < 0.001). Fibrovascular tissue ingrowth into the AGV was observed in the two patients in group 1and the same ingrowth was observed in 10 of the 16 patients in group 2. Six months after surgery the meanIOP among the 18 patients decreased significantly (19.1 ± 3.2 mmHg, p < 0.001). There was no significant differencein the mean postoperative IOP at 6 months between group 1 (14.0 ± 2.8 mmHg) and group 2 (19.8 ± 2.6mmHg, p = 0.052). Conclusions: Encapsulated bleb excision with collagen matrix implantation resulted in a significant IOP-loweringeffect 6 months after surgery. Fibrovascular ingrowth into the AGV was common but did not seem to bea major cause of AGV implantation failure.

참고문헌 (29)

  1. Quigley HA, "The number of people with glaucoma worldwide in 2010 and 2020", Br J Ophthalmol, 90, pp.262~267 (2006)
  2. Rosentreter A, "Capsule excision and Ologen implantation for revision after glaucoma drainage device surgery", Graefes Arch Clin Exp Ophthalmol, 248, pp.1319~1324 (2010)
  3. Lai JS, "Efficacy and safety of the Ahmed glaucoma valve implant in Chinese eyes with complicated glaucoma", Br J Ophthalmol, 84, pp.718~721 (2000)
  4. Coleman AL, "Initial clinical experience with the Ahmed glaucoma valve implant in pediatric patients", Arch Ophthalmol, 115, pp.186~191 (1997)
  5. Yang HK, "Clinical outcomes after Ahmed valve implantation in refractory paediatric glaucoma", Eye(Lond), 23, pp.1427~1435 (2009)
  6. Goulet RJ 3rd, "Efficacy of the Ahmed S2 glaucoma valve compared with the Baerveldt 250-mm2 glaucoma implant", Ophthalmology, 115, pp.1141~1147 (2008)
  7. Min Su Kim, "Changes in Corneal Endothelial Cell after Ahmed Glaucoma Valve Implantation and Trabeculectomy: 1-Year Follow-up", Korean Journal of Ophthalmology, 30(6), pp.416~425 (2016), 대한안과학회
  8. Gedde SJ, "Treatment outcomes in the Tube Versus Trabeculectomy(TVT)study after five years of follow-up", Am J Ophthalmol, 153, pp.789~803 (2012)
  9. Joshi AB, "2002 Survey of the American Glaucoma Society : practice preferences for glaucoma surgery and antifibrotic use", J Glaucoma, 14, pp.172~174 (2005)
  10. Desai MA, "Practice preferences for glaucoma surgery : a survey of the American Glaucoma Society in 2008", Ophthalmic Surg Lasers Imaging, 42, pp.202~208 (2011)
  11. Chen PP, "Needling revision of glaucoma drainage device filtering blebs", Ophthalmology, 104, pp.1004~1010 (1997)
  12. Jung KI, "Serial changes in the bleb wall after glaucoma drainage implant surgery : characteristics during the hypertensive phase", Acta Ophthalmol, 93, pp.e248~e253 (2015)
  13. Topouzis F, "Follow-up of the original cohort with the Ahmed glaucoma valve implant", Am J Ophthalmol, 128, pp.198~204 (1999)
  14. Huang MC, "Intermediate-term clinical experience with the Ahmed Glaucoma Valve implant", Am J Ophthalmol, 127, pp.27~33 (1999)
  15. Ayyala RS, "Comparison of mitomycin C trabeculectomy, glaucoma drainage device implantation, and laser neodymium : YAG cyclophotocoagulation in the management of intractable glaucoma after penetrating keratoplasty", Ophthalmology, 105, pp.1550~1556 (1998)
  16. Quaranta L, "Needle revision with 5-fluorouracil for the treatment of Ahmed glaucoma valve filtering blebs : 5-fluoruracil Needling revision can be a useful and safe tool in the management of failing Ahmed glaucoma valve filtering blebs", J Glaucoma, 25, pp.e367~e371 (2016)
  17. Shah AA, "Shunt revision versus additional tube shunt implantation after failed tube shunt surgery in ref ractory glaucoma", Am J Ophthalmol, 129, pp.455~460 (2000)
  18. Al-Mosallamy SM, "Decapsulation versus valve reimplantation in cases with an encysted Ahmed valve in refractory glaucoma", Delta J Ophthalmol, 16, pp.22~26 (2015)
  19. 김재령, "아메드방수유출장치 삽입술 후 발생한 조직 감입", 대한안과학회지, 53(7), pp.1053~1056 (2012), 대한안과학회[DOI]
  20. Wilson RP, "Molteno versus Schocket", Ophthalmology, 99, pp.672~676 (1992)
  21. Siegner SW, "Clinical experience with the Baerveldt glaucoma drainage implant", Ophthalmology, 102, pp.1298~1307 (1995)
  22. Hong CH, "Glaucoma drainage devices : a systematic literature review and current controversies", Surv Ophthalmol, 50, pp.48~60 (2005)
  23. Ishida K, "Ahmed Glaucoma Valve implantation in African American and white patients", Arch Ophthalmol, 124, pp.800~806 (2006)
  24. Song M, "Clinical and biological evaluations of biodegradable collagen matrices for glaucoma drainage device implantation", Invest Ophthalmol Vis Sci, 58, pp.5329~5335 (2017)
  25. Trigler L, "Fibrovascular ingrowth as a cause of Ahmed glaucoma valve failure in children", Am J Ophthalmol, 141, pp.388~389 (2006)
  26. Hill RA, "Pathophysiology of and prophylaxis against late Ahmed glaucoma valve occlusion", Am J Ophthalmol, 129, pp.608~612 (2000)
  27. Hsu WC, "Inhibition of conjunctival scarring and contraction by a porous collagen-glycosaminoglycan implant", Invest Ophthalmol Vis Sci, 41, pp.2404~2411 (2000)
  28. Stenzel KH, "Collagen as a biomaterial", Annu Rev Biophys Bioeng, 3, pp.231~253 (1974)
  29. Rho S, "Bleb analysis and short-term results of biodegradable collagen matrix-augmented Ahmed glaucoma valve implantation : 6-month follow-up", Invest Ophthalmol Vis Sci, 56, pp.5896~5903 (2015)

관련 논문AI추천

이 간행물의 다른 논문 (14건)