본문 바로가기
KERD
논문KCI 등재

Clinical Outcomes of Intrascleral Fixation of Intraocular Lens Compared to Ciliary Sulcus Implantation and Transscleral Fixation

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To compare the clinical outcomes of intrascleral fixation of the three-piece intraocular lenses (IOLs) 2.5 mm posteriorto the limbus with ciliary sulcus implantation and transscleral fixation 2.5 mm posterior to the limbus. Methods: Sixty-five eyes of 65 patients who underwent ciliary sulcus implantation or transscleral or intrascleral fixation ofthe AMO Sensar AR40e IOL were retrospectively reviewed. The postoperative refractive prediction error, back-calculatedeffective lens position (ELP), corrected distance visual acuity (CDVA), and postoperative residual cylinder were compared. Results: There were significant differences in the median (interquartile range) postoperative refractive prediction error (diopters[D]) among the three groups (p < 0.001): for ciliary sulcus implantation (33 eyes), −0.89 D (−1.21 to −0.56 D); for transscleralfixation (10 eyes), −0.40 D (−0.78 to −0.22 D); and for intrascleral fixation (22 eyes), 0.01 D (−0.28 to 0.34 D). Significantdifferences (p < 0.001) were observed in the median back-calculated ELP: for ciliary sulcus implantation, 4.35 mm (3.95 to4.55 mm); for transscleral fixation, 4.51 mm (4.34 to 4.76 mm); and for intrascleral fixation, 4.90 mm (4.56 to 5.35 mm). Therewere no differences in the median postoperative CDVA (0, 0.10, and 0 logarithm of the minimum angle of resolution, respectively;p = 0.083) and the residual cylinder (−0.75, −1.50, and −0.63 D, respectively; p = 0.074) among three groups. Conclusions: Intrascleral fixation showed no myopic shift and the most posterior lens position, while ciliary sulcus implantationinduced the greatest myopic shift and the most anterior lens position. However, there was no significant difference in thepostoperative CDVA or astigmatism among the eyes with different IOL insertion methods, demonstrating good IOL stabilityand vision outcomes.

Abstract

Purpose: To compare the clinical outcomes of intrascleral fixation of the three-piece intraocular lenses (IOLs) 2.5 mm posteriorto the limbus with ciliary sulcus implantation and transscleral fixation 2.5 mm posterior to the limbus. Methods: Sixty-five eyes of 65 patients who underwent ciliary sulcus implantation or transscleral or intrascleral fixation ofthe AMO Sensar AR40e IOL were retrospectively reviewed. The postoperative refractive prediction error, back-calculatedeffective lens position (ELP), corrected distance visual acuity (CDVA), and postoperative residual cylinder were compared. Results: There were significant differences in the median (interquartile range) postoperative refractive prediction error (diopters[D]) among the three groups (p < 0.001): for ciliary sulcus implantation (33 eyes), −0.89 D (−1.21 to −0.56 D); for transscleralfixation (10 eyes), −0.40 D (−0.78 to −0.22 D); and for intrascleral fixation (22 eyes), 0.01 D (−0.28 to 0.34 D). Significantdifferences (p < 0.001) were observed in the median back-calculated ELP: for ciliary sulcus implantation, 4.35 mm (3.95 to4.55 mm); for transscleral fixation, 4.51 mm (4.34 to 4.76 mm); and for intrascleral fixation, 4.90 mm (4.56 to 5.35 mm). Therewere no differences in the median postoperative CDVA (0, 0.10, and 0 logarithm of the minimum angle of resolution, respectively;p = 0.083) and the residual cylinder (−0.75, −1.50, and −0.63 D, respectively; p = 0.074) among three groups. Conclusions: Intrascleral fixation showed no myopic shift and the most posterior lens position, while ciliary sulcus implantationinduced the greatest myopic shift and the most anterior lens position. However, there was no significant difference in thepostoperative CDVA or astigmatism among the eyes with different IOL insertion methods, demonstrating good IOL stabilityand vision outcomes.

참고문헌 (30)

  1. Por YM, "Techniques of intraocular lens suspension in the absence of capsular", zonular support, 2005, pp.50, 429~462
  2. Park SY, "Scleral fixation of subluxated or dislocated multifocal and multifocal toric intraocular lenses", Graefes Arch Clin Exp Ophthalmol, 260, pp.1195~1203 (2022)
  3. Mehta R, "Intraocular lens implantation in the ciliary sulcus : challenges and risks", Clin Ophthalmol, 13, pp.2317~2323 (2019)
  4. Smiddy WE, "Implantation of scleral-fixated posterior chamber intraocular lenses", J Cataract Refract Surg, 16, pp.691~696 (1990)
  5. Gabor SG, "Sutureless intrascleral posterior chamber intraocular lens fixation", J Cataract Refract Surg, 33, pp.1851~1854 (2007)
  6. Yamane S, "Sutureless 27-gauge needle-guided intrascleral intraocular lens implantation with lamellar scleral dissection", Ophthalmology, 121, pp.61~66 (2014)
  7. Yamane S, "Flanged intrascleral intraocular lens fixation with double-needle technique", Ophthalmology, 124, pp.1136~1142 (2017)
  8. Mizuno Y, "A comparative study of transscleral suture-fixated and scleral-fixated intraocular lens implantation", Int Ophthalmol, 39, pp.839~845 (2019)
  9. Lee J, "Simple transscleral fixation of IOL technique without tying up haptics", Int J Ophthalmol, 13, pp.1152~1155 (2020)
  10. D’Agostino I, "Sutureless scleral fixation : comparison between 3-piece IOL and new single-piece foldable IOL", Graefes Arch Clin Exp Ophthalmol, 259, pp.1365~1373 (2021)
  11. Yamane S, "Flanged fixation : Yamane technique and its application", Curr Opin Ophthalmol, 32, pp.19~24 (2021)
  12. 조용운, "Short-term Clinical Outcomes after Transscleral Fixation Using the Intrascleral Pocket Technique: A Retrospective Cohort Study Analysis", Korean Journal of Ophthalmology, 30(2), pp.108~113 (2016), 대한안과학회
  13. Canabrava S, "Novel double-flanged technique for managing Marfan syndrome and microspherophakia", J Cataract Refract Surg, 46, pp.333~339 (2020)
  14. Canabrava S, "Double-flanged-haptic and capsular tension ring or segment for sutureless fixation in zonular instability", Int Ophthalmol, 38, pp.2653~2662 (2018)
  15. Narang P, "Glued intrascleral haptic fixation of an intraocular lens", Indian J Ophthalmol, 65, pp.1370~1380 (2017)
  16. Suto C, "Adjusting intraocular lens power for sulcus fixation", J Cataract Refract Surg, 29, pp.1913~1917 (2003)
  17. Choi SK, "Comparison of refractive deviations after phacovitrectomy according to the intraocular lens insertion method", Jpn J Ophthalmol, 64, pp.462~467 (2020)
  18. Eom Y, "Modified Haigis formula effective lens position equation for ciliary sulcus-implanted intraocular lenses", Am J Ophthalmol, 161, pp.142~149 (2016)
  19. Eom Y, "Posterior vault distance of ciliary sulcus-implanted three-piece intraocular lenses according to ciliary sulcus diameter", Am J Ophthalmol, 175, pp.52~59 (2017)
  20. Dubey R, "Improved refractive outcome for ciliary sulcus-implanted intraocular lenses", Ophthalmology, 119, pp.261~265 (2012)
  21. Lee R, "Refractive outcomes after sutureless intrascleral fixation of intraocular lens with pars plana vitrectomy", Retina, 41, pp.822~826 (2021)
  22. Fukasaku H, "Pinpoint anesthesia : a new approach to local ocular anesthesia", J Cataract Refract Surg, 20, pp.468~471 (1994)
  23. Baykara M, "Suture burial technique in scleral fixation", J Cataract Refract Surg, 30, pp.957~959 (2004)
  24. Eom Y, "Spectacle plane add power of multifocal intraocular lenses according to effective lens position", Can J Ophthalmol, 52, pp.54~60 (2017)
  25. Chang DF, "Curbside consultation in cataract surgery: 49 clinical questions" (2007), SLACK
  26. 장재호, "유리체절제술과 백내장 동시수술 시 모양체고랑 인공수정체삽입술 후의 굴절이상값", 대한안과학회지, 55(4), pp.513~518 (2014), 대한안과학회
  27. Iwase T, "Postoperative refraction changes in phacoemulsification cataract surgery with implantation of different types of intraocular lens", Eur J Ophthalmol, 18, pp.371~376 (2008)
  28. Todorich B, "Structural analysis and comprehensive surgical outcomes of the sutureless intrascleral fixation of secondary intraocular lenses in human eyes", Retina, 38(Suppl 1), pp.S31~40 (2018)
  29. Sugiura T, "Anatomy of the ciliary sulcus and the optimum site of needle passage for intraocular lens suture fixation in the living eye", J Cataract Refract Surg, 44, pp.1247~1253 (2018)
  30. Iglicki M, "Results in comparison between 30 gauge ultrathin wall and 27 gauge needle in sutureless intraocular lens flanged technique in diabetic patients : 24-month follow-up study", Acta Diabetol, 57, pp.1151~1157 (2020)

관련 논문AI추천

이 간행물의 다른 논문 (13건)