Long-term Results after Bilateral Implantation of Extended Depth of Focus Intraocular Lenses with Mini-Monovision
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: To assess long-term clinical results following bilateral Tecnis Symfony ZXR00 intraocular lens implantation with mini-monovision. Methods: The medical records of cataract patients who underwent bilateral implantation of ZXR00 with intended mini-monovision (target refraction of –0.3 diopters [D] in dominant eye and –0.6 D in nondominant eye) between April 2019 and March 2021 were assessed. Postoperative uncorrected distance visual acuity (UDVA), corrected distance VA (CDVA), uncorrected intermediate VA (UIVA), uncorrected near VA (UNVA), and rate of spectacle dependence for near distance were investigated at 3 months and 2 years after surgery. Results: This study included 61 patients (122 eyes) with average age of 61.8 ± 7.7 years. At 2 years postoperatively, binocular logarithm of the minimum angle of resolution UDVA, UIVA, UNVA, and CDVA were 0.086 ± 0.094, 0.056 ± 0.041, 0.140 ± 0.045, and 0.012 ± 0.024, respectively. The monocular manifest refraction spherical equivalent was –0.31 ± 0.38 in the dominant eye and –0.53 ± 0.47 in the nondominant eye at 3 months postoperatively, and –0.38 ± 0.43 in the dominant eye and –0.61 ± 0.54 in the nondominant eye at 2 years postoperatively. Eight out of 61 patients (13.1%) needed glasses 3 months after surgery, and nine out of 61 patients (14.8%) needed glasses 2 years after surgery. Conclusions: The bilateral implantation of ZXR00s with mini-monovision allows for a good VA at wide range of distance from far to near, thereby resulting in high rate of spectacle independence. These results have held up well even after 2 years after surgery.
Abstract
Purpose: To assess long-term clinical results following bilateral Tecnis Symfony ZXR00 intraocular lens implantation with mini-monovision. Methods: The medical records of cataract patients who underwent bilateral implantation of ZXR00 with intended mini-monovision (target refraction of –0.3 diopters [D] in dominant eye and –0.6 D in nondominant eye) between April 2019 and March 2021 were assessed. Postoperative uncorrected distance visual acuity (UDVA), corrected distance VA (CDVA), uncorrected intermediate VA (UIVA), uncorrected near VA (UNVA), and rate of spectacle dependence for near distance were investigated at 3 months and 2 years after surgery. Results: This study included 61 patients (122 eyes) with average age of 61.8 ± 7.7 years. At 2 years postoperatively, binocular logarithm of the minimum angle of resolution UDVA, UIVA, UNVA, and CDVA were 0.086 ± 0.094, 0.056 ± 0.041, 0.140 ± 0.045, and 0.012 ± 0.024, respectively. The monocular manifest refraction spherical equivalent was –0.31 ± 0.38 in the dominant eye and –0.53 ± 0.47 in the nondominant eye at 3 months postoperatively, and –0.38 ± 0.43 in the dominant eye and –0.61 ± 0.54 in the nondominant eye at 2 years postoperatively. Eight out of 61 patients (13.1%) needed glasses 3 months after surgery, and nine out of 61 patients (14.8%) needed glasses 2 years after surgery. Conclusions: The bilateral implantation of ZXR00s with mini-monovision allows for a good VA at wide range of distance from far to near, thereby resulting in high rate of spectacle independence. These results have held up well even after 2 years after surgery.
참고문헌 (33)
- Kim MJ, "Comparison of clinical outcomes among conventional scleral fixation, retropupillary iris-claw intraocular lens implantation, and intrascleral fixation", Korean J Ophthalmol, 36, pp.413~422 (2022)
- Rho CR, "Cataract surgery practice in the Republic of Korea : a survey of the Korean Society of Cataract and Refractive Surgery 2020", Korean J Ophthalmol, 35, pp.272~279 (2021)
- Paredes B, "Short-term clinical results with a trifocal diffractive toric intraocular lens using an optimized preoperative and intraoperative protocol", Eur J Ophthalmol, 34, pp.146~153 (2024)
- Kang KH, "Visual performance and optical quality after implantation of a new generation monofocal intraocular lens", Korean J Ophthalmol, 35, pp.112~119 (2021)
- Wang SY, "Patient-centered and visual quality outcomes of premium cataract surgery : a systematic review", Eur J Ophthalmol, 27, pp.387~401 (2017)
- Acar B, "Clinical outcome comparison:bilateral trifocal vs. mix-match extended depth of focus and trifocal intraocular lenses", Int Ophthalmol, 41, pp.3675~3686 (2021)
- Lesieur G, "A comparative evaluation of three extended depth of focus intraocular lenses", Eur J Ophthalmol, 33, pp.2106~2113 (2023)
- Rampat R, "Multifocal and extended depth-offocus intraocular lenses in 2020", Ophthalmology, 128, pp.e164~e185 (2021)
- Baur ID, "Clinical evaluation of reading performance in refractive lens exchange with a diffractive continuous-range-of-vision intraocular lens", Am J Ophthalmol, 250, pp.25~37 (2023)
- Kim JW, "Comparison of visual outcomes after two types of mix-and-match implanted trifocal extended-depth-of-focus and trifocal intraocular lenses", Graefes Arch Clin Exp Ophthalmol, 260, pp.3275~3283 (2022)
- van Amelsfort T, "Visual outcomes of a new nondiffractive extended depth-of-focus intraocular lens targeted for minimonovision : 3-month results of a prospective cohort study", J Cataract Refract Surg, 48, pp.151~156 (2022)
- Coassin M, "Effect of minimonovision in bilateral implantation of a novel non-diffractive extended depth-of-focus intraocular lens: defocus curves, visual outcomes, and quality of life", Eur J Ophthalmol, 32, pp.2942~2948 (2022)
- Jandewerth T, "Intolerance of a non-diff ractive extended-depth-of-focus IOL with mini-monovision", Am J Ophthalmol Case Rep, 29, pp.101770~ (2022)
- Roh YJ, "Assessment of risk factors affecting refractive outcomes after phacovitrectomy for epiretinal membrane", Korean J Ophthalmol, 37, pp.23~30 (2023)
- Kim BH, "Effects of bifocal versus trifocal diffractive intraocular lens implantation on visual quality after cataract surgery", Korean J Ophthalmol, 33, pp.333~342 (2019)
- Lee JH, "Clinical outcomes after mix-and-match implantation of extended depth of focus and diffractive multifocal intraocular lenses", J Ophthalmol, 2021, pp.8881794~ (2021)
- Shin DE, "Comparison of visual results and optical quality of two presbyopia-correcting intraocular lenses : TECNIS symfony versus TECNIS synergy", Eur J Ophthalmol, 32, pp.3461~3469 (2022)
- Choi M, "Visual outcomes after bilateral implantation of an extended depth of focus intraocular lens : a multicenter study", Korean J Ophthalmol, 34, pp.439~445 (2020)
- Son HS, "Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population", BMC Ophthalmol, 19, pp.187~ (2019)
- Tan J, "Visual quality and performance following bilateral implantation of TECNIS Symfony intraocular lenses with or without micro-monovision", Clin Ophthalmol, 13, pp.1071~1077 (2019)
- Kim JH, "Rainbow halos occur less following implantation of extended range of vision onepiece intraocular lenses vs diffractive bifocal intraocular lenses", Int J Ophthalmol, 13, pp.913~919 (2020)
- Cochener B, "Clinical outcomes of a new extended range of vision intraocular lens : International Multicenter Concerto Study", J Cataract Refract Surg, 42, pp.1268~1275 (2016)
- Ganesh S, "Visual and refractive outcomes following bilateral implantation of extended range of vision intraocular lens with micromonovision", J Ophthalmol, 2018, pp.7321794~ (2018)
- Pedrotti E, "Comparative analysis of objective and subjective outcomes of two different intraocular lenses : trifocal and extended range of vision", BMJ Open Ophthalmol, 5, pp.e000497~ (2020)
- Kim S, "Comparative analysis of the clinical outcomes of mix-and-match implantation of an extended depth-of-focus and a diffractive bifocal intraocular lens", Eye Contact Lens, 48, pp.261~266 (2022)
- Mencucci R, "Comparative analysis of visual outcomes, reading skills, contrast sensitivity, and patient satisfaction with two models of trifocal diffractive intraocular lenses and an extended range of vision intraocular lens", Graefes Arch Clin Exp Ophthalmol, 256, pp.1913~1922 (2018)
- Alio JL, "Multifocal intraocular lenses : an overview", Surv Ophthalmol, 62, pp.611~634 (2017)
- Lamba A, "Retrospective analysis on the visual outcomes and photic phenomena following bilateral extended depth of focus intraocular lens implants", Can J Ophthalmol, 55, pp.126~130 (2020)
- Rodov L, "Visual outcomes and patient satisfaction for trifocal, extended depth of focus and monofocal intraocular lenses", J Refract Surg, 35, pp.434~440 (2019)
- Hisai T, "Visual function in eyes with diffractive extended depth-of-focus and monofocal intraocular lenses : 2-year comparison", Graefes Arch Clin Exp Ophthalmol, 261, pp.2567~2573 (2023)
- Almenara C, "Comparison of posterior capsule opacification between Clareon CNA0T0 and Tecnis ZCB00 intraocular lenses", Eur J Ophthalmol, 31, pp.3355~3366 (2021)
- Leydolt C, "Posterior capsule opacification and neodymium : YAG rates with 2 single-piece hydrophobic acrylic intraocular lenses : three-year results", J Cataract Refract Surg, 39, pp.1886~1892 (2013)
- Xiong T, "Comparison of bilateral implantation of an extended depth of focus lenses and a blend approach of extended depth of focus lenses and bifocal lenses in cataract patients", BMC Ophthalmol, 23, pp.476~ (2023)