의수 제어용 동작 인식을 위한 웨어러블 밴드 센서
Wearable Band Sensor for Posture Recognition towards Prosthetic Control
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
The recent prosthetic technologies pursue to control multi-DOFs (degrees-of-freedom) hand and wrist. However, challenges such as high cost, wear-ability, and motion intent recognition for feedback control still remain for the use in daily living activities. The paper proposes a multi-channel knit band sensor to worn easily for surface EMG-based prosthetic control. The knitted electrodes were fabricated with conductive yarn, and the band except the electrodes are knitted using non-conductive yarn which has moisture wicking property. Two types of the knit bands are fabricated such as sixteen-electrodes for eight-channels and thirty-two electrodes for sixteen-channels. In order to substantiate the performance of the biopotential signal acquisition, several experiments are conducted. Signal to noise ratio (SNR) value of the knit band sensor was 18.48 dB. According to various forearm motions including hand and wrist, sixteen-channels EMG signals could be clearly distinguishable. In addition, the pattern recognition performance to control myoelectric prosthesis was verified in that overall classification accuracy of the RMS (root mean squares) filtered EMG signals (97.84%) was higher than that of the raw EMG signals (87.06%).
Abstract
The recent prosthetic technologies pursue to control multi-DOFs (degrees-of-freedom) hand and wrist. However, challenges such as high cost, wear-ability, and motion intent recognition for feedback control still remain for the use in daily living activities. The paper proposes a multi-channel knit band sensor to worn easily for surface EMG-based prosthetic control. The knitted electrodes were fabricated with conductive yarn, and the band except the electrodes are knitted using non-conductive yarn which has moisture wicking property. Two types of the knit bands are fabricated such as sixteen-electrodes for eight-channels and thirty-two electrodes for sixteen-channels. In order to substantiate the performance of the biopotential signal acquisition, several experiments are conducted. Signal to noise ratio (SNR) value of the knit band sensor was 18.48 dB. According to various forearm motions including hand and wrist, sixteen-channels EMG signals could be clearly distinguishable. In addition, the pattern recognition performance to control myoelectric prosthesis was verified in that overall classification accuracy of the RMS (root mean squares) filtered EMG signals (97.84%) was higher than that of the raw EMG signals (87.06%).
참고문헌 (19)
- V. Marozas, "A comparison of conductive textile-based and silver", silver chloride gel electrodes in exercise electrocardiogram recordings, 2011, pp.44(2), 189~194
- J. S. Head, "The use of an adjustable electrode housing unit to compare electrode alignment and contact variation with myoelectric prosthesis functionality: A pilot study", Prosthetics and orthotics international, 40(1), pp.123~128 (2016)
- C. W. Moran, "Revolutionizing prosthetics 2009 modular prosthetic limb-body interface: Overview of the prosthetic socket development", Johns Hopkins APL Technical Digest, 30(3), pp.250~255 (2011)
- R. Paradiso, "A wearable health care system based on knitted integrated sensors", IEEE transactions on Information Technology in biomedicine, 9(3), pp.337~344 (2005)
- C. Cochrane, "Design and development of a flexible strain sensor for textile structures based on a conductive polymer composite", Sensors, 7(4), pp.473~492 (2007)
- J. Löfhede, "Textile Electrodes for EEG Recording—A pilot study", Sensors, 12(12), pp.16907~16919 (2012)
- W. Wu, "Quantitative Assessment for Self-Tracking of Acute Stress based on Triangulation Principle in a Wearable Sensor System", IEEE Journal of Biomedical and Health Informatics, pp.1~1 (2018)
- X. Xiao, "Performance evaluation of plain weave and honeycomb weave electrodes for human ECG monitoring", Journal of Sensors, 2017, pp.13~ (2017)
- W. Wu, "Assessment of biofeedback training for emotion management through wearable textile physiological monitoring system", IEEE Sensors Journal, 15(12), pp.7087~7095 (2015)
- M. K. Yapici, "Intelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors", Sensors, 17(4), pp.875~ (2017)
- F. Cordella, "Literature review on needs of upper limb prosthesis users", Frontiers in neuroscience, 10, pp.209~ (2016)
- E. A. Biddiss, "Upper limb prosthesis use and abandonment: a survey of the last 25 years", Prosthetics and orthotics international, 31(3), pp.236~257 (2007)
- Y. Jiang, "A highly usable and customizable sEMG sensor for prosthetic limb control using polypyrrole-coated nonwoven fabric sheet", 2015 IEEE SENSORS, pp.1~4 (2015)
- Y. Jiang, "sEMG Sensor Using Polypyrrole-Coated Nonwoven Fabric Sheet for Practical Control of Prosthetic Hand", Frontiers in neuroscience, 11, pp.33~ (2017)
- S. Brown, "Intarsia-sensorized band and textrodes for real-time myoelectric pattern recognition", 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), pp.6074~6077 (2016)
- K. Yang, "Screen printed fabric electrode array for wearable functional electrical stimulation", Sensors and Actuators A: Physical, 213, pp.108~115 (2014)
- S. A. Lee, "Development of knit band electrodes for multi-channel sEMG measurement", 2017 14th International Conference on Ubiquitous Robots and Ambient Intelligence (URAI), pp.827~829 (2017)
- S. Lee, "Knit Band Sensor for Myoelectric Control of Surface EMG-based Prosthetic Hand", IEEE Sensors Journal, 18(20) (2018)
- 김영진, "근전도 신호를 이용한 손목 힘 및 악력 추정", 로봇학회 논문지, 12(2), pp.206~216 (2017), 한국로봇학회
