Evaluation of the safety and efficacy of home-use micro-focused ultrasound: a preclinical study

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류의학일반

초록

Background: The demand for home-use micro-focused ultrasound (MFU) devices for dermatologic uses like facial skin tightening and treating forms of skin laxity is increasing. However, the procedures used to evaluate such devices remain underdeveloped.Methods: We performed simulations on ex vivo porcine tissues to calculate the thermal coagulation point (TCP) area corresponding to the applied energy levels. Surface and intradermal temperature distributions posttreatment on porcine dorsal skin were assessed during MFU. Subsequently, we evaluated the safety and effectiveness of the MFU device in vivo after single or repeated treatments. MFU energy was delivered in vivo to porcine skin at 7 MHz and 12 W to a penetration depth of 3.0 mm under different experimental settings. Tissue samples were obtained immediately after treatment and 14 days later and subjected to histological analysis.Results: TCPs were distinctly observed in ex vivo tissues after MFU. Energy-dependent micro-coagulation zones were small at ~1 mm3. The temperature escalation was linearly proportional to the number of treatments. Notably, MFU treatment promoted collagen and elastin deposition in vivo and induced neocollagenesis in the mid and deep reticular dermis and neoelastogenesis in the deep reticular dermis.Conclusion: The novel MFU energy regimen used in this study was effective in our animal model, and the energy settings used may mitigate unwanted side effects. Our results show that a home-use MFU device that provides uniform TCP and precise treatment can be safely applied to the face and effectively tightens skin.

Abstract

Background: The demand for home-use micro-focused ultrasound (MFU) devices for dermatologic uses like facial skin tightening and treating forms of skin laxity is increasing. However, the procedures used to evaluate such devices remain underdeveloped.Methods: We performed simulations on ex vivo porcine tissues to calculate the thermal coagulation point (TCP) area corresponding to the applied energy levels. Surface and intradermal temperature distributions posttreatment on porcine dorsal skin were assessed during MFU. Subsequently, we evaluated the safety and effectiveness of the MFU device in vivo after single or repeated treatments. MFU energy was delivered in vivo to porcine skin at 7 MHz and 12 W to a penetration depth of 3.0 mm under different experimental settings. Tissue samples were obtained immediately after treatment and 14 days later and subjected to histological analysis.Results: TCPs were distinctly observed in ex vivo tissues after MFU. Energy-dependent micro-coagulation zones were small at ~1 mm3. The temperature escalation was linearly proportional to the number of treatments. Notably, MFU treatment promoted collagen and elastin deposition in vivo and induced neocollagenesis in the mid and deep reticular dermis and neoelastogenesis in the deep reticular dermis.Conclusion: The novel MFU energy regimen used in this study was effective in our animal model, and the energy settings used may mitigate unwanted side effects. Our results show that a home-use MFU device that provides uniform TCP and precise treatment can be safely applied to the face and effectively tightens skin.

참고문헌 (15)

  1. Khan U, "A systematic review of the clinical efficacy of micro-focused ultrasound treatment for skin rejuvenation and tightening", Cureus, 13, pp.e20163~ (2021)
  2. Kwon TR, "Improved methods for evaluating pre-clinical and histological effects of subcutaneous fat reduction using high-intensity focused ultrasound in a porcine model", Skin Res Technol, 23, pp.194~201 (2017)
  3. White WM, "Selective transcutaneous delivery of energy to porcine soft tissues using Intense Ultrasound(IUS)", Lasers Surg Med, 40, pp.67~75 (2008)
  4. Aşiran Serdar Z, "Efficacy of high-intensity focused ultrasound in facial and neck rejuvenation", J Cosmet Dermatol, 19, pp.353~358 (2020)
  5. Bove T, "High-frequency(20-MHz)high-intensity focused ultrasound(HIFU)system for dermal intervention : preclinical evaluation in skin equivalents", Skin Res Technol, 25, pp.217~228 (2019)
  6. Choi SY, "Tightening effects of high-intensity focused ultrasound on body skin and subdermal tissue : a pilot study", J Eur Acad Dermatol Venereol, 30, pp.1599~1602 (2016)
  7. Fabi SG, "Retrospective evaluation of micro-focused ultrasound for lifting and tightening the face and neck", Dermatol Surg, 40, pp.569~575 (2014)
  8. Grisey A, "Influence of skin and subcutaneous tissue on high-intensity focused ultrasound beam : experimental quantification and numerical modeling", Ultrasound Med Biol, 42, pp.2457~2465 (2016)
  9. Lee HJ, "The efficacy and safety of intense focused ultrasound in the treatment of enlarged facial pores in Asian skin", J Dermatolog Treat, 26, pp.73~77 (2015)
  10. Jiaqi Ling, "A Systematic Review and Meta-Analysis of the Clinical Efficacy and Patients’ Satisfaction of Micro-focused Ultrasound (MFU) Treatment for Facial Rejuvenation and Tightening", Aesthetic Plastic Surgery, 47(5), pp.1806~1823 (2023), Springer Science and Business Media LLC[DOI]
  11. Lee TJ, "Rejuvenation of photoaged aged mouse skin using high-intensity focused ultrasound", J Plast Reconstr Aesthet Surg, 75, pp.3859~3868 (2022)
  12. Park JH, "High-intensity focused ultrasound treatment for skin : ex vivo evaluation", Skin Res Technol, 23, pp.384~391 (2017)
  13. Suh DH, "Intense focused ultrasound(IFUS)with a modified parameter on facial tightening : a study on its safety and efficacy", J Cosmet Laser Ther, 18, pp.448~451 (2016)
  14. Kwack MH, "Efficacy of a home-used high-intensity focused ultrasound device on wrinkle reduction", Skin Res Technol, 29, pp.e13266~ (2023)
  15. Zawada T, "Strongly focused HIFU transducers with simultaneous optical observation for treatment of skin at 20MHz", Ultrasound Med Biol, 48, pp.1309~1327 (2022)

관련 논문AI추천

Efficacy and safety of a home-use multi-energy-based device for skin tightening: a preclinical studyDong Wook Moon, Hwan Mo Seong, Hye Sung Han, Jungkwan Lee, Jungwook Kim, Kwang Ho Yoo, Sun Young Choi, Tae-Rin Kwon, Woo Geon Lee, Yoon Hwan Lee대한의학레이저학회 · Medical Lasers2023 · 제12권 제3호Safety and efficacy of a novel non-invasive monopolar radiofrequency device for skin tightening in a porcine model in Republic of Korea: pre-clinical studyHye Guk Ryu, Jinyoung Park, Jumi Hong, Sangjune Kim, Soo Il Chun, Wanil Kim대한의학레이저학회 · Medical Lasers2025 · 제14권 제4호High-Intensity Focused Ultrasound for the Treatment of Wrinkles and Skin Laxity in Seven Different Facial Areas고주연, 김은진, 김정은, 노영석, 박현철대한피부과학회 · Annals of Dermatology2015 · 제27권 제6호Glabellar wrinkle improvement after forehead and periorbital micro-focused ultrasound treatment in Republic of Korea: a case reportChong Hyun Won, Do Hyung Kim, Joon Min Jung, Myoung Eun Choi대한의학레이저학회 · Medical Lasers2023 · 제12권 제2호Comparison of two microfocused ultrasound treatment protocols for eyebrow lifting in a Korean female cohort in Republic of Korea: a split-face clinical studyChong Hyun Won, Ik Jun Moon, Jihun Choi, Joon Min Jung, Kang Su Kim, Myoung Eun Choi대한의학레이저학회 · Medical Lasers2025 · 제14권 제4호Skin tightening effecacy and safety: high-intensity focused ultrasound alone or in combination with monopolar radiofreqeuncy treatment in Republic of Korea: retrospective clinical studyCha Han Gyu, Lee Seo Koo, Nam Seung Min, Park Eun Soo대한의학레이저학회 · Medical Lasers2023 · 제12권 제4호

이 간행물의 다른 논문 (9건)