Comparison of Bonding Strength by Cleaning Method of Pediatric Zirconia Crown Contaminated with Saliva or Blood
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The objective of this study was to compare the shear bonding strength of zirconia after cleaning the crown contaminated by saliva or blood and determine the effect of thermocycling. 180 specimens were embedded in acrylic resin. 20 Specimens in the positive control group were bonded with resin cement without contamination. 20 Specimens in the negative control group were washed with water for 20 seconds and then dried for 10 seconds. 120 Specimens contaminated by saliva or blood were cleaned by using three cleaning methods: 37% phosphoric acid gel, commercial cleanse, and 2.5% NaOCl. All samples were bonded with resin cement and divided into two subgroups: One was not aged, and the other was tested with 30,000 thermocycling. In both groups contamination by saliva and blood, no statistically significant difference was not found in control, groups cleansed by commercial cleanser and 2.5% NaOCl. When the groups cleansed with water and 37% phosphate gel were compared with the control, significantly low shear bond strength was shown. Thermocycling group showed statistically significantly low shear bond stress compared to the groups without thermocycling. When zirconia was contaminated by saliva or blood, its original shear bond strength could be obtained if it was cleaned with commercial cleanser or 2.5% NaOCl.
Abstract
The objective of this study was to compare the shear bonding strength of zirconia after cleaning the crown contaminated by saliva or blood and determine the effect of thermocycling. 180 specimens were embedded in acrylic resin. 20 Specimens in the positive control group were bonded with resin cement without contamination. 20 Specimens in the negative control group were washed with water for 20 seconds and then dried for 10 seconds. 120 Specimens contaminated by saliva or blood were cleaned by using three cleaning methods: 37% phosphoric acid gel, commercial cleanse, and 2.5% NaOCl. All samples were bonded with resin cement and divided into two subgroups: One was not aged, and the other was tested with 30,000 thermocycling. In both groups contamination by saliva and blood, no statistically significant difference was not found in control, groups cleansed by commercial cleanser and 2.5% NaOCl. When the groups cleansed with water and 37% phosphate gel were compared with the control, significantly low shear bond strength was shown. Thermocycling group showed statistically significantly low shear bond stress compared to the groups without thermocycling. When zirconia was contaminated by saliva or blood, its original shear bond strength could be obtained if it was cleaned with commercial cleanser or 2.5% NaOCl.
참고문헌 (28)
- Komine F, "Influence of different adhesive resin cements on the fracture strength of aluminum oxide ceramic posterior crowns", J Prosthet Dent, 92, pp.359~364 (2004)[DOI]
- Piconi C, "Zirconia as a ceramic biomaterial", Biomaterials, 20, pp.1~25 (1999)[DOI]
- Denry I, "State of the art of zirconia for dental applications", Dent Mater, 24, pp.299~307 (2008)[DOI]
- Thompson JY, "Adhesion", cementation to zirconia and other non-silicate ceramics: where are we now?, 2011, pp.27, 71~82
- Amaral R, "Effect of conditioning methods on the microtensile bond strength of phosphate monomer-based cement on zirconia ceramic in dry and aged conditions", J Biomed Mater Res B Appl Biomater, 85, pp.1~9 (2008)
- Blatz MB, "Resin-ceramic bonding: a review of the literature", J Prosthet Dent, 89, pp.268~274 (2003)[DOI]
- Phark JH, "An in vitro evaluation of the long-term resin bond to a new densely sintered high-purity zirconium-oxide ceramic surface", J Prosthet Dent, 101, pp.29~38 (2009)[DOI]
- El Zohairy AA, "The effect of adhesives with various degrees of hydrophilicity on resin ceramic bond durability", Dent Mater, 20, pp.778~787 (2004)[DOI]
- Hahn P, "Influence of resin cement viscosity on microleakage of ceramic inlays", Dent Mater, 17, pp.191~196 (2001)[DOI]
- Yang B, "Influence of saliva contamination on zirconia ceramic bonding", Dent Mater, 24, pp.508~513 (2008)[DOI]
- Yang B, "Influence of contamination on zirconia ceramic bonding", J Dent Res, 86, pp.749~753 (2007)[DOI]
- Aboush YE, "Removing saliva contamination from porcelain veneers before bonding", J Prosthet Dent, 80, pp.649~653 (1998)[DOI]
- Zhang Y, "Damage accumulation and fatigue life of particle-abraded ceramics", Int J Prosthodont, 19, pp.442~448 (2006)
- Zhang Y, "Effect of sandblasting on the long-term performance of dental ceramics", J Biomed Mater Res B Appl Biomater, 71, pp.381~386 (2004)
- Souza RO, "Air-particle abrasion on zirconia ceramic using different protocols: effects on biaxial flexural strength after cyclic loading, phase transformation and surface topography", J Mech Behav Biomed Mater, 26, pp.155~163 (2013)[DOI]
- El-Korashy DI, "Mechanical properties and bonding potential of partially stabilized zirconia treated with different chemomechanical treatments", J Adhes Dent, 16, pp.365~376 (2014)
- 김다혜, "Efficacy of various cleaning solutions on saliva-contaminated zirconia for improved resin bonding", The Journal of Advanced of Prosthodontics, 7(2), pp.85~92 (2015), 대한치과보철학회[DOI]
- Ishii R, "Influence of surface treatment of contaminated zirconia on surface free energy and resin cement bonding", Dent Mater J, 34, pp.91~97 (2015)[DOI]
- Boehm RF, "Thermal environment of teeth during openmouth respiration", J Dent Res, 51, pp.75~78 (1972)[DOI]
- Palmer DS, "Temperature extremes produced orally by hot and cold liquids", J Prosthet Dent, 67, pp.325~327 (1992)[DOI]
- Quaas AC, "Panavia F 2.0 bonding to contaminated zirconia ceramic after different cleaning procedures", Dent Mater, 23, pp.506~512 (2007)[DOI]
- Gale MS, "Thermal cycling procedures for laboratory testing of dental restorations", J Dent, 27, pp.89~99 (1999)[DOI]
- Luthy H, "Effect of thermocycling on bond strength of luting cements to zirconia ceramic", Dent Mater, 22, pp.195~200 (2006)[DOI]
- Zhang S, "Influence of contamination on resin bond strength to nano-structured aluminacoated zirconia ceramic", Eur J Oral Sci, 118, pp.396~403 (2010)[DOI]
- Barakat MM, "In vitro bond strength of cements to treated teeth", Aust Dent J, 31, pp.415~419 (1986)[DOI]
- Song JY, "Fracture strength and microstructure of Y-TZP zirconia after different surface treatments", J Prosthet Dent, 110, pp.274~280 (2013)[DOI]
- Angkasith P, "Cleaning Methods for Zirconia Following Salivary Contamination", J Prosthodont, 25, pp.375~379 (2016)[DOI]
- Siqueira JF Jr., "Effects of chemomechanical preparation with 2.5% sodium hypochlorite and intracanal medication with calcium hydroxide on cultivable bacteria in infected root canals", J Endod, 33, pp.800~805 (2007)[DOI]
