본문 바로가기
KERD
논문KCI 등재

Clinical Usefulness of the Jones Jig Appliance for Alignment of Premolars and Molars: Case Reports

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Early loss of the primary maxillary second molar can lead to complications in which mesial drift of the adjacent first molar (M1) can disturb eruption of the succedaneous second premolar (P2). This study reports two cases of space loss for P2 caused by early exfoliation of its predecessor. After the eruption of the first premolar, the Jones jig appliance was used to distalize M1 and regain space for the eruption of P2. The appliance was further utilized to align the palatally erupted P2 into the dental arch. In both cases, the space and corrected position of P2 were well maintained. Early exfoliation of the primary second molar caused by mesial encroachment of M1 is a common phenomenon, and pediatric dentists should attend to this during routine examinations. An appropriate intervention should be initiated when the primary second molar is lost during the mixed dentition period. If used with careful anchorage control, the Jones jig appliance can effectively resolve this problem.

Abstract

Early loss of the primary maxillary second molar can lead to complications in which mesial drift of the adjacent first molar (M1) can disturb eruption of the succedaneous second premolar (P2). This study reports two cases of space loss for P2 caused by early exfoliation of its predecessor. After the eruption of the first premolar, the Jones jig appliance was used to distalize M1 and regain space for the eruption of P2. The appliance was further utilized to align the palatally erupted P2 into the dental arch. In both cases, the space and corrected position of P2 were well maintained. Early exfoliation of the primary second molar caused by mesial encroachment of M1 is a common phenomenon, and pediatric dentists should attend to this during routine examinations. An appropriate intervention should be initiated when the primary second molar is lost during the mixed dentition period. If used with careful anchorage control, the Jones jig appliance can effectively resolve this problem.

참고문헌 (29)

  1. Haydar S, "Comparison of Jones jig molar distalization appliance with extraoral traction", Am J Orthod Dentofacial Orthop, 117, pp.49~53 (2000)
  2. Blechman AM, "Magnetic force in orthodontics", Am J Orthod, 74, pp.435~443 (1978)
  3. Gianelly AA, "Japanese NiTi coils used to move molars distally", Am J Orthod Dentofacial Orthop, 99, pp.564~566 (1991)
  4. Hilgers JJ, "The pendulum appliance for Class II non-compliance therapy", J Clin Orthod, 26, pp.706~714 (1992)
  5. Jones RD, "Rapid Class II molar correction with an open-coil jig", J Clin Orthod, 26, pp.661~664 (1992)
  6. Kalra V, "The K-loop molar distalizing appliance", J Clin Orthod, 29, pp.298~301 (1995)
  7. Carano A, "The distal jet for upper molar distalization", J Clin Orthod, 30, pp.374~380 (1996)
  8. Gulati S, "Dental and skeletal changes after intraoral molar distalization with sectional jig assembly", Am J Orthod Dentofacial Orthop, 114, pp.319~327 (1998)
  9. Rock WP, "UK national clinical guidelines in paediatric dentistry. extraction of primary teeth - balance and compensation", Int J Paediatr Dent, 12, pp.151~153 (2002)
  10. Meade MJ, "Eruption disturbances in the mixed dentition : orthodontic considerations for primary dental care", Aust Dent J, 67(Suppl 1), pp.S14~S23 (2022)
  11. Barberia-Leache E, "Ectopic eruption of the maxillary first permanent molar : characteristics and occurrence in growing children", Angle Orthod, 75, pp.610~615 (2005)
  12. Dabbagh B, "Ectopic eruption of the permanent maxillary first molar : predictive factors for irreversible outcome", Pediatr Dent, 39, pp.215~218 (2017)
  13. Chen X, "Ectopic eruption of the first permanent molar : predictive factors for irreversible outcome", Am J Orthod Dentofacial Orthop, 159, pp.E169~E177 (2021)
  14. Gianelly AA, "Distal movement of the maxillary molars", Am J Orthod Dentofacial Orthop, 114, pp.66~72 (1998)
  15. Karlsson I, "Intraoral maxillary molar distalization", Angle Orthod, 76, pp.923~929 (2006)
  16. Kinzinger GS, "Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage", Am J Orthod Dentofacial Orthop, 125, pp.8~23 (2004)
  17. Bussick TJ, "Dentoalveolar and skeletal changes associated with the pendulum appliance", Am J Orthod Dentofacial Orthop, 117, pp.333~343 (2000)
  18. Jeon EK, "Maxillary molar distalization and premolar alignment with a Jones jig appliance : case reports", J Korean Acad Pediatr Dent, 37, pp.497~504 (2010)
  19. Keles A, "Maxillary unilateral molar distalization with sliding mechanics : a preliminary investigation", Eur J Orthod, 23, pp.507~515 (2001)
  20. Lee HJ, "Maxillary molar distalization with a pendulum appliance", J Korean Acad Pediatr Dent, 35, pp.523~531 (2008)
  21. Sfondrini MF, "Upper molar distalization : a critical analysis", Orthod Craniofac Res, 5, pp.114~126 (2002)
  22. Ravera S, "Maxillary molar distalization with aligners in adult patients : a multicenter retrospective study", Prog Orthod, 17, pp.12~ (2016)
  23. Caruso S, "Impact of molar teeth distalization with clear aligners on occlusal vertical dimension : a retrospective study", BMC Oral Health, 19, pp.182~ (2019)
  24. Brickman CD, "Evaluation of the Jones jig appliance for distal molar movement", Am J Orthod Dentofacial Orthop, 118, pp.526~534 (2000)
  25. Patel MP, "Comparative distalization effects of Jones jig and pendulum appliances", Am J Orthod Dentofacial Orthop, 135, pp.336~342 (2009)
  26. Mavropoulos A, "Efficiency of noncompliance simultaneous first and second upper molar distalization : a three-dimensional tooth movement analysis", Angle Orthod, 75, pp.532~539 (2005)
  27. Jang YG, "Maxillary molar distalization with the bone-supported pendulum", J Korean Acad Pediatr Dent, 36, pp.464~474 (2009)
  28. Bayome M, "Distalization of maxillary molars using temporary skeletal anchorage devices : a systematic review and meta-analysis", Orthod Craniofac Res, 24(Suppl 1), pp.S103~S112 (2021)
  29. Shetty S, "Comparison of the pendulum appliance and the Jones jig : a prospective comparative study", Eur J Dent, 11, pp.323~329 (2017)

관련 논문AI추천

이 간행물의 다른 논문 (9건)