We proposed an MEA development methodology that accurately measures intrinsic MEA performance while considering the uneven reaction environments formed inside a large-area BP. To facilitate measurement of the inherent MEA performance, we miniaturized the active area of the MEA to 3 cm2, and prepared two MEAs with different ionomer contents of 0.65 and 0.80 (I/C). By simulating the operating conditions of a 100 cm2 BP at the inlet (I), center (C), and outlet (O), the oxygen concentration and relative humidity were determined to be 20.7, 13.8, 11.7%, and 50, 66.1, and 70.1% respectively. We measured the performance and electrochemical analysis of the prepared MEAs under the three simulated conditions. Based on the results of statistical analysis of the evaluated MEA performance data, I/C 0.65 MEA had a higher average performance and lower performance deviation than I/C 0.80 MEA. Hence, it can be concluded that an I/C 0.65 MEA is a more effective MEA for large-area BP. Based on the above research process, we confirmed the effectiveness of the proposed MEA development methodology.

Abstract

We proposed an MEA development methodology that accurately measures intrinsic MEA performance while considering the uneven reaction environments formed inside a large-area BP. To facilitate measurement of the inherent MEA performance, we miniaturized the active area of the MEA to 3 cm2, and prepared two MEAs with different ionomer contents of 0.65 and 0.80 (I/C). By simulating the operating conditions of a 100 cm2 BP at the inlet (I), center (C), and outlet (O), the oxygen concentration and relative humidity were determined to be 20.7, 13.8, 11.7%, and 50, 66.1, and 70.1% respectively. We measured the performance and electrochemical analysis of the prepared MEAs under the three simulated conditions. Based on the results of statistical analysis of the evaluated MEA performance data, I/C 0.65 MEA had a higher average performance and lower performance deviation than I/C 0.80 MEA. Hence, it can be concluded that an I/C 0.65 MEA is a more effective MEA for large-area BP. Based on the above research process, we confirmed the effectiveness of the proposed MEA development methodology.

참고문헌 (9)

  1. O’hayre, R, "Fuel cell fundamentals" (2017), Hanteemedia
  2. Oh, S.M, "Electrochemistry" (2014), Freeacademy
  3. Vielstich, W, "Handbook of fuel cells. Fundamentals, technology, applications" (2003), John Wiley & Sons
  4. 임성대, "데칼법을 이용한 연속 제조 공정에서의 고분자 전해질 연료전지용 전극 개발", 신재생에너지, 6(1), pp.46~52 (2010), 한국신·재생에너지학회
  5. 이원용, "고온 고분자연료전지 기반 삼중열병합 시스템의 이론적 해석", 신재생에너지, 13(2), pp.59~68 (2017), 한국신·재생에너지학회
  6. Neyerlin, K. C, "Cathode catalyst utilization for the ORR in a PEMFC: Analytical model and experimental validation", Journal of The Electrochemical Society, 154(2), pp.279~287 (2007)
  7. Neyerlin, K. C, "Effect of relative humidity on oxygen reduction kinetics in a PEMFC", Journal of The Electrochemical Society, 152(6), pp.1073~1080 (2005)
  8. Orfanidi, A, "The key to high performance low Pt loaded electrodes", Journal of The Electrochemical Society, 164(4), pp.418~426 (2017)
  9. Choi, B, "The effect of cathode structures on Nafion membrane durability", Journal of The Electrochemical Society, 161(12), pp.1154~1162 (2014)