본문 바로가기
KERD
논문KCI 등재

Standard와 MAR 알고리즘에서 CT 검사조건 변화에 따른 인공물과 노이즈 평가

Evaluation of Artifact and Noise in the Standard and MAR Algorithms with Variation of Examination Conditions of CT

3

조회

0

다운로드

7

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The influence of metal artifact in CT image depends on the type of metal materialsm, the reconstruction algorithm, and scan parameters. The presence of metal artifacts was quantitatively evaluated by applying the standard and MAR algorithms through the phantom study. In the change of tube voltage applied the standard algorithm, metal artifact decreased to 44.9% for 80 vs 120 kVp, 24% for 100 vs 120 kVp, while the image taken at 140 kVp increased the artifact by 19% compared to 120 kVp. When the tube current was increased from 100 to 300 mA, there was no significant difference in the CT value and noise. Black band and white strike artifacts occurred up to 65.9% in the adjacent ROI of the metal driver, whereas titanium screw produced lesser metal artifact than that of the metal driver. The combination of 120kVp or higher tube voltage-standard algorithm was effective in removing black band artifacts as well as white streak by high density materials. However, MAR reconstruction algorithm was useful in improving image quality under the environment of low kVp and high density materials, without increase of radiation exposure.

Abstract

The influence of metal artifact in CT image depends on the type of metal materialsm, the reconstruction algorithm, and scan parameters. The presence of metal artifacts was quantitatively evaluated by applying the standard and MAR algorithms through the phantom study. In the change of tube voltage applied the standard algorithm, metal artifact decreased to 44.9% for 80 vs 120 kVp, 24% for 100 vs 120 kVp, while the image taken at 140 kVp increased the artifact by 19% compared to 120 kVp. When the tube current was increased from 100 to 300 mA, there was no significant difference in the CT value and noise. Black band and white strike artifacts occurred up to 65.9% in the adjacent ROI of the metal driver, whereas titanium screw produced lesser metal artifact than that of the metal driver. The combination of 120kVp or higher tube voltage-standard algorithm was effective in removing black band artifacts as well as white streak by high density materials. However, MAR reconstruction algorithm was useful in improving image quality under the environment of low kVp and high density materials, without increase of radiation exposure.

참고문헌 (11)

  1. 김현주, "Iterative Metallic Artifact Reduction 알고리즘 적용 CT 재구성영상의 CT Number 변화율 분석", 한국산학기술학회논문지, 18(7), pp.84~91 (2017), 한국산학기술학회[DOI]
  2. Anderson KM, "Visual grading evaluation of commercially available metal artefact reduction techniques in hip prosthesis computed tomography", The British Journal of Radiology, 89(1063), pp.1~11 (2016)
  3. Andersson KM, "Metal artefact reduction in CT imaging of hip prostheses an evaluation of commercial techniques provided by four vendors", The British Journal of Radiology, 88, pp.1~7 (2015)
  4. 김현주, "Brain CT에서 발생하는 선속경화현상 감소방안에 관한 연구", 한국산학기술학회논문지, 16(12), pp.8479~8486 (2015), 한국산학기술학회[DOI]
  5. 김명성, "듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용", 방사선방어학회지, 36(2), pp.79~85 (2011), 테스트학회
  6. Kim YJ, "Dual-Energy and Iterative Metal Artifact Reduction for Reducing Artifacts Due to Metallic Hardware : A Loosening Hip Phantom Study", American Journal of Roentgenology, 212, pp.1106~1111 (2019)
  7. Moon SG, "Metal artifact reduction by the alteration of technical factors in multidetector computed tomography : A 3-dimensional quantitative assessment", J Comput Assist Tomogr, 2(4), pp.630~633 (2008)
  8. White SC, "Oral radiology: Principles and interpretation", pp.196~ (2014), Elsevier-Mosby
  9. Panjnoush M, "Effect of Exposure Parameters on Metal Artifacts in Cone Beam Computed Tomography", Journal of Dentistry of Tehran University of Medical Sciences, 13(3), pp.143~150 (2016)
  10. Gjesteby L, "Metal artifact reduction in CT: Where are we after four decades?", IEEE, 4, pp.2169~3536 (2016)
  11. 김현주, "CT의 MAR알고리즘 적용 시 의료용 금속 물질별 인공물 감소율 분석", 한국산학기술학회논문지, 17(9), pp.655~662 (2016), 한국산학기술학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (7건)