Usefulness of CT based SPECT Fusion Image in the lung Disease:Preliminary Study
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease.Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing.However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA Phantom™ (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.
Abstract
Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease.Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing.However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA Phantom™ (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.
참고문헌 (12)
- Freeman LM, "Enhanced lung scan diagnosis of pulmonary embolism with the use of ancillary scintigraphic findings and clinical correlation", Semin Nucl Med, 31, pp.143~157 (2001)
- Goldberg SN, "Pleural effusion and the ventilation-perfusion scan interpretation for acute pulmonary embolus", J Nucl Med, 37, pp.1310~1318 (1996)
- Gottschalk A, "Overview of prospective investigation of pulmonary embolism diagnosis II", Semin Nucl Med, 32, pp.173~182 (2002)
- Gottschalk A, "Very low probability interpretation of V", Q lung scans in combination with low probability objective clinical assessment reliably excludes pulmonary embolism: Data from PIOPED II, 2007, pp.48, 1411~1415
- Gray HW, "The natural history of venous thromboembolism: impact on ventilation", perfusion scan reporting, 2002, pp.32, 159~172
- Sostman HD, "The stripe sign: a new sign for diagnosis of nonembolic defects on pulmonary embolism", J Nucl Med, 37, pp.737~741 (1996)
- Stein PD, "Evaluation of the positive predictive value of specific criteria used for the assessment of low probability ventilation", perfusion lung scans, 1996, pp.37, 577~581
- Stein PD, "Diagnostic pathways in acute pulmonary embolism : recommendations of the PIOPED II investigators", Am J Med, 119, pp.1048~1055 (2006)
- The PIOPED Investigators, "Value of the ventilation", perfusion scan in acute pulmonary embolism : results of the Prospective Investigation of Pulmonary Embolism Diagnosis(PIOPED), 1990, pp.263, 2753~2759
- Worsely DF, "Comprehensive analysis of the results of the PIOPED study. Prospective investigation of pulmonary embolism diagnosisstudy", J Nucl Med, 36, pp.2380~2387 (1995)
- Suga K, "Findings of hepatopumonary syndrome on breath-hold perfusion SPECT-CT fusion images", Ann Nucl Med, 23, pp.413~419 (2009)
- Suga K, "Automated breath-hold perfusion SPECT-CT fusion images", Am J Roentgenol, 189, pp.455~463 (2007)
