개발한 진단용 다엽조리개 성능평가 및 X선영상과 적외선체열영상의 융합영상 구현
Performance Evaluation of the Developed Diagnostic Multi-Leaf Collimator and Implementation of Fusion Image of X-ray Image and Infrared Thermography Image
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.
Abstract
We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.
참고문헌 (22)
- Teng J, "A multimodality medical image fusion algorithm based on wavelet transform", International Conference in Swarm Intelligence, pp.627~633 (2010), Springer
- James AP, "Medical image fusion, A survey of the state of the art", Information Fusion, 19, pp.4~19 (2014)
- 정우경, "투시와 중재시술의 방사선 피폭과 저감화 방법", 대한의사협회지, 54(12), pp.1269~1276 (2011), 대한의사협회
- Korean society of medical imaging technology, "Textbook of radiographic positioning and clinical diagnosis" (2017), Chungku publisher
- Research society of radiation equipment, "Radiation equipment" (2017), Chungku publisher
- "KS A 4732. Variable X-ray beam limiting devices for diagnostic use", ~ (1997)
- "IEC 60601-1-33. General rule for X-ray equipment", ~ (2008)
- 한수철, "진단용 다엽콜리메이터 개발을 위한 몬테칼로 시뮬레이션 연구", 방사선기술과학, 39(4), pp.595~600 (2016), 대한방사선과학회[DOI]
- Seungwoo Park, "A Study on Development and Usefulness of new Multi-Leaf Collimator for Diagnostic X-ray Equipment", Journal of Electrical Engineering & Technology, 13(2), pp.936~942 (2018), 대한전기학회
- Le Heron JC, "Estimation of effective dose to the patient during medical X-ray examinations from measurements of the dose-area product", Physics in Medicine & Biology, 37(11), pp.2117~ (1992)
- 권순무, "디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화", 한국방사선학회논문지, 9(7), pp.535~540 (2015), 한국방사선학회[DOI]
- 강영한, "디지털 심혈관조영장치의 기하학적 특성에 따른 선량 감소", 한국방사선학회논문지, 7(4), pp.277~284 (2013), 한국방사선학회[DOI]
- Bor D, "Comparison of effective doses obtained from dose–area product and air kerma measurements in interventional radiology", The British Journal of Radiology, 77(916), pp.315~322 (2004)
- 최성관, "X선 촬영에서 조사야 크기에 따른 산란선량의 변화", 한국콘텐츠학회 논문지, 13(3), pp.198~203 (2013), 한국콘텐츠학회[DOI]
- 조평곤, "투시 검사실 내 공간산란선 분포 측정", 한국콘텐츠학회 논문지, 11(10), pp.349~354 (2011), 한국콘텐츠학회
- Buchanan JB, "Tumor growth, doubling times, and the inability of the radiologist to diagnose certain cancers", Radiologic Clinics of North America, 21(1), pp.115~126 (1983)
- 박정규, "디지털 적외선 체열진단기를 이용한 추간판탈출증 환자의 ROI 온도측정", 한국방사선학회논문지, 11(4), pp.273~278 (2017), 한국방사선학회[DOI]
- Sim JH, "Diagnostic significance of digital infrared thermographic imaging after cerebrovascular stroke", Journal of Korean Neurosurgical Society, 27(7), pp.890~897 (1998)
- Sanchis-Sánchez E, "Infrared thermography is useful for ruling out fractures in pediatric emergencies", European Journal of Pediatrics, 174(4), pp.493~499 (2015)
- Kwon SM, "X-ray inspection device and its inspection method", Korea Patent 10-1743469, ~ (2017)
- Kwon SM, "Diagnosis method and device of breast disease", Korea Patent 10-1828367, ~ (2018)