High-Resolution thoracic CT (HRCT) is a scanning protocol in which thin slice thickness and sharpness algorithm are utilized to enhance image resolution for diagnosis and assessment of interstitial lung disease (ILD). This examination is sometimes performed in both supine and prone position to improve sensitivity to early changes of these conditions. Anatomical structures (the size of lung field and heart and descending aorta) of 150 patients who underwent HRCT were retrospectively compared. HRCT had been conducted in two positions (supine and prone). Data were divided into five groups according to patient body weights (from 40 to more than 80kg, 10kg intervals, 60 patients/each group). Quantitative analysis was utilized in Image J program. In the supine position defined as the control group, the average values of lung fields and heart size and aorta were compared with the prone position defined as the experimental group. The size of the lungs was found to be higher in the supine position, and it was confirmed that there was a statistically significant difference in patients over 70 kg (p<0.05). In addition, both sizes of the heart and descending aorta were larger in prone position, but in the case of the heart, there was no correlation with the presence or absence of ILD disease (p>0.05). Also, the area of prone in the descending aorta was higher than supine position, but there was no statistically significant difference between supine and prone position (p>0.05). In conclusion, when the severity of ILD disease was severe, there was no statistically significant difference in the area difference between supine and prone position, so it is considered that it will be helpful in diagnostic decision.
Abstract
High-Resolution thoracic CT (HRCT) is a scanning protocol in which thin slice thickness and sharpness algorithm are utilized to enhance image resolution for diagnosis and assessment of interstitial lung disease (ILD). This examination is sometimes performed in both supine and prone position to improve sensitivity to early changes of these conditions. Anatomical structures (the size of lung field and heart and descending aorta) of 150 patients who underwent HRCT were retrospectively compared. HRCT had been conducted in two positions (supine and prone). Data were divided into five groups according to patient body weights (from 40 to more than 80kg, 10kg intervals, 60 patients/each group). Quantitative analysis was utilized in Image J program. In the supine position defined as the control group, the average values of lung fields and heart size and aorta were compared with the prone position defined as the experimental group. The size of the lungs was found to be higher in the supine position, and it was confirmed that there was a statistically significant difference in patients over 70 kg (p<0.05). In addition, both sizes of the heart and descending aorta were larger in prone position, but in the case of the heart, there was no correlation with the presence or absence of ILD disease (p>0.05). Also, the area of prone in the descending aorta was higher than supine position, but there was no statistically significant difference between supine and prone position (p>0.05). In conclusion, when the severity of ILD disease was severe, there was no statistically significant difference in the area difference between supine and prone position, so it is considered that it will be helpful in diagnostic decision.
참고문헌 (34)
- Brenner DJ, "Computed tomography-an increasing source of radiation exposure", N Engl J Med, 357(22), pp.2277~2284 (2007)
- 이만구, "CT검사건수 및 CT검사에 의한 집단 실효선량의 추정", 방사선기술과학, 33(3), pp.231~238 (2010), 대한방사선과학회
- "Cause of death statistics in 2019"[URL]
- Aberle DR, "The national lung screening trial : Overview and study design", Radiology, 258(1), pp.243~253 (2011)
- Sarma A, "Elliott CG. Radiation and chest CT scan examinations: What do we know?", CHEST, 143(2), pp.750~760 (2012)
- Kalra MK, "Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT : A pilot study", Radiology, 259(2), pp.565~573 (2011)
- Hara AK, "Iterative reconstruction technique for reducing body radiation dose at CT : Feasibility study", AJR Am J Roentgenol, 193(3), pp.764~771 (2009)
- Raghu G, "Diagnosis of idiopathic pulmonary fibrosis. An official ATS", ERS, ALAT clinical practice guideline, pp.American Journal of Respiratory and Critical Care Medicine, 2018[DOI]
- Muller NL, "Computed tomography in chronic interstitial lung disease", Radiol Clin North Am, 29(5), pp.1085~1093 (1991)
- Nishimura K, "The diagnostic accuracy of high-resolution computed tomography in diffuse infiltrative lung diseases", Chest, 104(4), pp.1149~1159 (1993)
- Scatarige JC, "Utility of high-resolution CT for management of diffuse lung disease: Results of a survey of U.S. pulmonary physicians", Acad Radiol, 10(2), pp.167~175 (2003)
- Volpe J, "High-resolution CT of the lung : Determination of the usefulness of CT scans obtained with the patient prone based on plain radiographic findings", AJR Am J Roentgenol, 169(2), pp.369~374 (1997)
- Nishino M, "Value of volumetric data acquisition in expiratory high-resolution computed tomography of the lung", J Comput Assist Tomogr, 28(2), pp.209~214 (2004)
- Bartholmai BJ, "Quantitative computed tomography imaging of interstitial lung diseases", J Thorac Imaging, 28(5), pp.298~307 (2013)
- Weatherley ND, "Experimental and quantitative imaging techniques in interstitial lung disease", Thorax, 74(6), pp.611~619 (2019)
- Montesi SB, "Practice guidelines for interstitial lung diseases : Widening the reach", Lung India, 37(4), pp.289~291 (2020)
- Lederer DJ, "Idiopathic pulmonary fibrosis", N Engl J Med, 378, pp.1811~1823 (2018)
- 오유환, "특발성 간질성 폐렴의 영상의학적 접근", 대한내과학회지, 84(4), pp.489~497 (2013), 대한내과학회[DOI]
- Padley SP, "Comparative accuracy of high resolution computed tomography and chest radiography in the diagnosis of chronic diffuse infiltrative lung disease", Clinical Radiology, 44(4), pp.222~226 (1991)
- Nishimura K, "The diagnostic accuracy of high-resolution computed tomography in diffuse infiltrative lung diseases", Chest, 104(4), pp.1149~1159 (1993)
- Na WG, "HRCT Finding in relation to age: Emphasis on air trapping and diameter of pulmonary artery in secondary pulmonary lobule", pp.2000
- Zompatori M, "Diagnostic imaging of diffuse infiltrative disease of the lung", Respiration, 71(1), pp.4~19 (2004)
- Albert RK, "The prone position eliminates compression of the lungs by the heart", American Journal of Respiratory and Critical Care Medicine, 161(5), pp.1660~1665 (2000)
- William SB, "Prone-supine change in organ position : CT demonstration", AJR AM J Roentgenol, 135(4), pp.815~820 (1980)
- Choo DW, "A study on the radiographic determination of total lung capacity in various age groups of normal Korean", J Korean Radiol Soc, 14(2), pp.262~272 (1978)
- Park SS, "A study on the radiographic determination of total lung capacity in normal Korean adults", J Korean Radiol Soc, 6(1), pp.15~24 (1970)
- Kim HL, "A study of radiographic determination of the total lung capacity in the normal Korean school children", J Korean Radiol Soc, 9(2), pp.135~145 (1973)
- 박여진, "디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측", 방사선기술과학, 41(1), pp.1~6 (2018), 대한방사선과학회[DOI]
- 주영철, "한국인 성인 남성의 흉부 방사선영상에서 자세와 연령에 따른 심장 크기 및 심흉비의 정상 범위와 변환율", 방사선기술과학, 40(2), pp.179~186 (2017), 대한방사선과학회[DOI]
- 주영철, "흉부 방사선검사 영상을 이용한 한국인 정상 여성의 임신기와 비 임신기 심장크기와 심흉비 비교", 방사선기술과학, 41(3), pp.223~229 (2018), 대한방사선과학회[DOI]
- 이건, "다중검출 전산화 단층촬영을 이용하여 측정한 흉부대동맥의 직경", Journal of Chest Surgery, 42(1), pp.79~86 (2009), 대한심장혈관흉부외과학회
- Shin JJ, "The anatomical properties of size of abdominal aorta in Korean normal adult populations", The Korean Society for Vascular Surgery, 25(1), pp.7~11 (2009)
- Ki Baek Lee, "Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels: A Phantom Study in Chest CT", Korean Journal of Radiology, 19(1), pp.119~129 (2018), 대한영상의학회[DOI]
- Lee KB, "Comparison of quantitative image quality of cardiac computed tomography between raw-data-based and model-based iterative reconstruction algorithms with an emphasis on image sharpness", Pediatric Radiology, 50(11), pp.1570~1578 (2020)