Iopamidol과 Ioversol 제제 조영제의 사용 후 보관 기간에 따른 1H-NMR 분석
1H-NMR Analysis according to the Storage Period after the Use of Iopamidol and Ioversol Formulations Contrast Agents
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Since the side effects of contrast agents occur in many ways, hospitals must clearly identify the contrast agents and know how to manage them. Storage of contrast media It is common practice to store contrast media in a warm room to reduce viscosity and improve patient comfort. However, it is important to recognize that long-term storage at high temperatures can shorten the shelf life of a product. Therefore, in this study, the presence or absence of chemical changes according to the storage period after using the contrast medium was analyzed. As the analysis equipment, a 500 MHz Nuclear Magnetic Resonance Spectrometer of Bruker Avance (Germany) possessed by Korea Basic Science Institute (KOREA BASIC SCIENCE INSTITUTE; KBSI) was used. For the X-ray iodide contrast medium, Pamiray contrast medium of Iopamidol and Optiray contrast medium of Ioversol, samples remaining after 7 days, 20 days, 30 days, and 1 year were collected, By acquiring the spectrum from the 1H-NMR spectrometer of the contrast medium stimulated by It was compared and analyzed with the standard sample. In conclusion, depending on the storage period of the contrast medium, no peaks of physical and chemical changes were observed in both the Pamiray contrast medium of Iopamidol and the Optiray contrast medium of Ioversol after 7 days, 20 days, 30 days, and 1 year after use.
Abstract
Since the side effects of contrast agents occur in many ways, hospitals must clearly identify the contrast agents and know how to manage them. Storage of contrast media It is common practice to store contrast media in a warm room to reduce viscosity and improve patient comfort. However, it is important to recognize that long-term storage at high temperatures can shorten the shelf life of a product. Therefore, in this study, the presence or absence of chemical changes according to the storage period after using the contrast medium was analyzed. As the analysis equipment, a 500 MHz Nuclear Magnetic Resonance Spectrometer of Bruker Avance (Germany) possessed by Korea Basic Science Institute (KOREA BASIC SCIENCE INSTITUTE; KBSI) was used. For the X-ray iodide contrast medium, Pamiray contrast medium of Iopamidol and Optiray contrast medium of Ioversol, samples remaining after 7 days, 20 days, 30 days, and 1 year were collected, By acquiring the spectrum from the 1H-NMR spectrometer of the contrast medium stimulated by It was compared and analyzed with the standard sample. In conclusion, depending on the storage period of the contrast medium, no peaks of physical and chemical changes were observed in both the Pamiray contrast medium of Iopamidol and the Optiray contrast medium of Ioversol after 7 days, 20 days, 30 days, and 1 year after use.
참고문헌 (18)
- Kim MC, "Textbook of computed tomography" (2020), Chung Ku Publisher
- Wang CL, "Frequency, outcome, and appropriateness of treatment of nonionic iodinated contrast media reactions", AJR, 191(2), pp.409~415 (2008)
- 강영한, "조영제 부작용에 대한 주의의무와 제조물책임", 방사선기술과학, 30(4), pp.305~311 (2007), 대한방사선과학회
- Kwon KS, "Anlaysis of Adverse Reactions to CT contrast Medium", pp.2004
- Thrall JH, "Pharmaceuticals in medical imaging", pp.253~277 (1990), Macmillan
- Cohan RH, "Extravasation of radiographic contrast material : Recognition, prevention, and treatment", Radiology, 200, pp.593~604 (1996)
- Kim SH, "Experimental tissue damage after subcutaneous injection of water soluble contrast media", Invest Radiol, 25, pp.678~685 (1990)
- Sistrom CL, "Extravasation of iopamidol and iohexol during contrast-enhanced CT : A report of 28 cases", Radiology, 180, pp.707~710 (1991)
- Penry JB, "A comparison of diagnostic effectiveness and vascular side-effects of various diatrizoate salts used for intravenous pyelography", Clin Radiol, 23, pp.362~369 (1972)
- Evill CA, "Chemotoxic effects of low-osmolar contrast media on the blood brain barrier", Invest Radiol, 25, pp.S82~S83 (1990)
- Blum W, "Hyperthy-roidism after iodinated contrast medium", N Engl J Med, 291, pp.24~25 (1974)
- Sidhu PS, "Guidelines for the management of reactions to intravenous contrast media", Royal College of Radiologists, ~ (1993)
- Dawson P, "Textbook Contrast Media" (1999), British Library
- Lee SK., "The analysis of NMR spectrum" (2014), Hanrimwon
- Cardinal HN, "Experimental and theoretical X-ray imaging performance comparison of iodine and lanthanide contrast agents", Med Phys, 20, pp.15~31 (1993)
- 유성민, "컴퓨터단층촬영의 요오드화 조영제 부작용으로 인한 사망 관련 조영제 비교 분석", 방사선기술과학, 44(1), pp.47~52 (2021), 대한방사선과학회
- 한범희, "Iopamidol과 Ioversol 제제 조영제의 온도변화에 따른 물리화학적 분석", 방사선기술과학, 43(4), pp.273~280 (2020), 대한방사선과학회
- "Dongkook Life Science" (2017)[URL]
