In this study, we tested the absorption of CO2 in combustion gas into an alkaline wastewater to simultaneously control CO2 and wastewater. During the experiment, we investigated the effects of operating parameters on neutralization characteristics of the wastewater by using CO2 in a bench-scale semi-batch jet loop reactor (0.1 m diameter and 1.0 m in height). The operating parameters investigated in the study are gas flow rate of 1.0-2.0 L/min, liquid recirculation flow rate of 4-32 L/min, and liquid temperature of 20-25℃. It was shown that the initial pH of wastewater rapidly decreased with increased gas flow rate for a given liquid recirculation flow rate. This was due to the increase in the gas holdup and the interfacial area at higher gas flow rate in the reactor. At constant gas flow rate, the time required to neutralize the wastewater initial pH of 10.1 decreased with liquid recirculation flow rate (QL), reached a minimum value in the range of QL = 16-24 L/min, and then increased with further increase in QL. Further, the time required to neutralize the wastewater was shortened at higher temperatures.
Abstract
In this study, we tested the absorption of CO2 in combustion gas into an alkaline wastewater to simultaneously control CO2 and wastewater. During the experiment, we investigated the effects of operating parameters on neutralization characteristics of the wastewater by using CO2 in a bench-scale semi-batch jet loop reactor (0.1 m diameter and 1.0 m in height). The operating parameters investigated in the study are gas flow rate of 1.0-2.0 L/min, liquid recirculation flow rate of 4-32 L/min, and liquid temperature of 20-25℃. It was shown that the initial pH of wastewater rapidly decreased with increased gas flow rate for a given liquid recirculation flow rate. This was due to the increase in the gas holdup and the interfacial area at higher gas flow rate in the reactor. At constant gas flow rate, the time required to neutralize the wastewater initial pH of 10.1 decreased with liquid recirculation flow rate (QL), reached a minimum value in the range of QL = 16-24 L/min, and then increased with further increase in QL. Further, the time required to neutralize the wastewater was shortened at higher temperatures.
참고문헌 (14)
- Go, K. S., "A study on utilization of CO2-rich exhaust gas for pH control of alkaline wastewater", 석사, pp.2010
- Chia-Chang Lin, "Carbon Dioxide Absorption into NaOH Solution in a Cross-flow Rotating Packed Bed", Journal of Industrial and Engineering Chemistry, 13(7), pp.1083~1090 (2007), 한국공업화학회
- Fleischer, C., "Detailed modeling of the chemisorption of CO2 into NaOH in a bubble column", Chemical Engineering Science, 51(10), pp.1715~1724 (1996)
- Park, S. W., "Gas absorption of CO2 into emulsion with alkaline aqueous solutions", J. of the Korean institute of chemical engineers, 35(4), pp.476~484 (1997)
- Gaddis, E. S., "Mass transfer in gas-liquid contactors", Chemical Engineering and Processing, 38, pp.503~510 (1990)
- Chriastel, L., "New concept of jet loop bioreactor", Nova Biotechnoligica, 4(1), pp.89~100 (2006)
- Maurizio, P., "Aerobic treatment of winery wastewater using a jet loop activated sludge reactor", Process Biochemistry, 37(8), pp.821~829 (2002)
- Kang, S. H., "The effects of influent loading rate in piggery wastewater treatment by Jet Loop Reactor", Environmental re, 21(5-B), pp.567~573 (2001)
- 박종탁, "활성탄 담체가 포함된 Jet-Loop Reactor를 이용한 종합염색폐수처리", KSBB Journal, 17(3), pp.241~246 (2002), 한국생물공학회
- Yildiz, E., "High strength wastewater treatment in a jet loop membrane bioreactor: kinetics and performance evaluation", Chemical Engineering Science, 60, pp.1106~1116 (2005)
- Velan, M., "Mixing time in a down-flow jet loop bioreactor", Bioprocess Engineering, 12, pp.81~86 (1995)
- Prasad, K. Y., "Overall volumetric mass transfer coefficient in a modified reversed flow jet loop bioreactor with low density particles", Bioprocess Engineering, 12, pp.209~214 (1995)
- Peng, Y., "Advance in postcombustion CO2 capture with alkaline solution: a brief review", Energy Procedia, 14, pp.1515~1522 (2012)
- Pohorecki, R., "Kinetics of reaction between carbon dioxide and hydroxyl ions in aqueous electrolyte solutions", Chemical Engineering Science, 43(7), pp.1677~1684 (1998)