본문 바로가기
KERD
논문KCI 등재

무지 외반증의 중증도에 대한 전산화 영상 계측

The Computerized Measurement for the Radiological Severity of Hallux Valgus

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Purpose: To study the reliability of intra- and interobserver reliability in angular measurement of hallux valgus deformity by assessing hallux valgus angle (HVA) and the 1st to 2nd intermetatarsal angle (1-2 IMA) through using computerized system. Materials and Methods: 20 cases of moderate to severe hallux valgus patients were included in this study. With the standing anteroposterior view of foot, the HVA and 1-2 IMA were calculated by computerized measurement system of Infinity cooperation, called π-view, with its software tools. Using the statistical software program, SPSS (version 12th), we interpreted the results which were measured by two independent observers. Results: In the intraobserver measurement, the HVA of observer A showed reliability (32.5°±6.9 and 33.1°±6.8)(p<0.05). 1-2 IMA in observer A was not regarded as reliable (16.9°±2.8 and 17.1°±2.8)(p>0.05). In the results of observer B, HVAs were measured as 35.7°±7.6 and 36.2°±7.7, and were not reliable (p>0.05). 1-2 IMA in observer B was not reliable as well (17.0°±0.8 and 20.8°±1.5)(p>0.05). In the interobservers’ measurements, the first and the second results of HVA were 3.2°±3.6 and 3.1°±3.1, reliable within the 95% confidence interval (p<0.05). 1-2 IMAs were 0.1°±1.9 and 3.73°±1.3, which were not reliable (p>0.05). Conclusion: In the angular measurement of the hallux valgus by computerized system, the HVA and 1-2 IMA showed less error range in the interobserver’s results, compared with the previous studies about the manual measurement. However, our results failed to show the statistical reliability of intra- and interobserver’s measuring. Therefore, even the computerized angular measurements in the severity of hallux valgus require development of the measuring methods and software tools.

Abstract

Purpose: To study the reliability of intra- and interobserver reliability in angular measurement of hallux valgus deformity by assessing hallux valgus angle (HVA) and the 1st to 2nd intermetatarsal angle (1-2 IMA) through using computerized system. Materials and Methods: 20 cases of moderate to severe hallux valgus patients were included in this study. With the standing anteroposterior view of foot, the HVA and 1-2 IMA were calculated by computerized measurement system of Infinity cooperation, called π-view, with its software tools. Using the statistical software program, SPSS (version 12th), we interpreted the results which were measured by two independent observers. Results: In the intraobserver measurement, the HVA of observer A showed reliability (32.5°±6.9 and 33.1°±6.8)(p<0.05). 1-2 IMA in observer A was not regarded as reliable (16.9°±2.8 and 17.1°±2.8)(p>0.05). In the results of observer B, HVAs were measured as 35.7°±7.6 and 36.2°±7.7, and were not reliable (p>0.05). 1-2 IMA in observer B was not reliable as well (17.0°±0.8 and 20.8°±1.5)(p>0.05). In the interobservers’ measurements, the first and the second results of HVA were 3.2°±3.6 and 3.1°±3.1, reliable within the 95% confidence interval (p<0.05). 1-2 IMAs were 0.1°±1.9 and 3.73°±1.3, which were not reliable (p>0.05). Conclusion: In the angular measurement of the hallux valgus by computerized system, the HVA and 1-2 IMA showed less error range in the interobserver’s results, compared with the previous studies about the manual measurement. However, our results failed to show the statistical reliability of intra- and interobserver’s measuring. Therefore, even the computerized angular measurements in the severity of hallux valgus require development of the measuring methods and software tools.

참고문헌 (23)

  1. Van Vo H, "A comparison of 4 common methods of hand-measured techniques with a computerized technique to measure the first intermetatarsal angle", J Foot Ankle Surg, 43, pp.395~399 (2004)
  2. Shea KG, "A comparison of manual versus computer-assisted radiographic measurement. intraobserver measurement variability for Cobb angles", Spine, 23, pp.551~55 (1998)
  3. Coughlin MJ, "Angular measurements in the evaluation of hallux valgus deformities: a report of the ad hoc committee of the American Orthopaedic Foot & Ankle Society on angular measurements", Foot Ankle Int, 23, pp.68~74 (2002)
  4. Chiodo CP, "Clinical results with the Ludloff osteotomy for correction of adult hallux valgus", Foot Ankle Int, 25, pp.532~536 (2004)
  5. Panchbhavi VK, "Comparison between manual and computer-assisted measurements of hallux valgus parameters", Foot Ankle Int, 25, pp.708~711 (2004)
  6. Hamers S, "Digital radiography with a large-scale electronic flat-panel detector vs. screenfilm radiography: observer preference in clinical skeletal diagnostics", Eur Radiol, 11, pp.1753~1759 (2001)
  7. Farber DC, "Goniometric versus computerized angle measurement in assessing hallux valgus", Foot Ankle Int, 26, pp.234~238 (2005)
  8. Coughlin MJ, "Hallux valgus", J Bone Joint Surg, 78-A, pp.932~966 (1996)
  9. Smith RW, "Hallux valgus assessment: report of research committee of American Orthopaedic Foot and Ankle Society", Foot Ankle, 5, pp.92~103 (1984)
  10. Mann RA, "Hallux valgus--etiology, anatomy, treatment and surgical considerations", Clin Orthop Relat Res, 157, pp.31~41 (1981)
  11. Schneider W, "Intra-and interobserver repeatability of radiographic measurements in hallux surgery: improvement and validation of a method", Acta Orthop Scand, 73, pp.670~673 (2002)
  12. Resch S, "Measuring hallux valgus: a comparison of conventional radiography and clinical parameters with regard to measurement accuracy", Foot Ankle Int, 16, pp.267~270 (1995)
  13. Jones DH, "Modern concepts in the treatment of hallux valgus", J Bone Joint Surg, 88-B, pp.276~ (2006)
  14. Hardy RH, "Observations on hallux valgus; based on a controlled series", J Bone Joint Surg, 33-B, pp.376~392 (1951)
  15. Piqué-Vidal C, "Radiographic angles in hallux valgus: differences between measurements made manually and with a computerized program", Foot Ankle Int, 27, pp.175~180 (2006)
  16. Menz HB, "Radiographic validation of the Manchester scale for the classification of hallux valgus deformity", Rheumatology (Oxford), 44, pp.1061~1066 (2005)
  17. De Carvalho A, "Reliability analysis for manual measurement of coronal plane deformity in adolescent scoliosis. Are 30 x 90 cm plain films better thandigitized small films?", Eur Spine J, 16, pp.1615~1620 (2007)
  18. Mann RA, "Repair of hallux valgus with a distal soft-tissue procedure and proximal metatarsal osteotomy: A long-term follow-up", J Bone Joint Surg, 74-A, pp.124~129 (1992)
  19. Schneider W, "Reproducibility of the radiographic metatarsophalangeal angle in hallux surgery", J Bone Joint Surg, 85-A, pp.494~499 (2003)
  20. Condon F, "The first intermetatarsal angle in hallux valgus: an analysis of measurement reliability and the error involved", Foot Ankle Int, 23, pp.717~721 (2002)
  21. Coughlin MJ, "The reliability of angular measurements in hallux valgus deformities", Foot Ankle Int, 22, pp.369~379 (2001)
  22. Kilmartin TE, "A controlled prospective trial ofa foot orthosis for juvenile hallux valgus", J Bone Joint Surg, 76-B, pp.210~214 (1994)
  23. Vittetoe DA, "Validity and reliability of the first distal metatarsal articular angle", Foot Ankle Int, 15, pp.541~547 (1994)

관련 논문AI추천