외측 족관절 불안정성 환자에서 봉합 나사와 PushLock Anchor를 이용한 변형 Brostrom 술식
Modified Brostrom Procedure with Suture Anchor & PushLock Anchor in Lateral Ankle Instability
1
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
Purpose: The purpose of our study was to perform a comparison of the outcomes of the modified Brostrom procedure using only a suture anchor compared with using a suture anchor with a pushlock anchor. Materials and Methods: This was a retrospective study of chronic lateral ankle instability that underwent a modified Brostrom procedure using a bioabsorbable suture anchor & a pushlock anchor, performed by a single surgeon. A total of 88patients were enrolled in the study. The function of the patient’s ankles were scored using the American Orthopaedic Foot and Ankle Society (AOFAS), visual analogue scale (VAS) both preoperatively and postoperatively. Results: The difference in the overall means between the group A and group B was not statistically significant. But, the patient’s satisfaction was better in the group B, and there were more complications in the group A. Conclusion: The technique presented here uses the modified Brostrom procedure with pushlock anchors to prevent the problems associated with subcutaneous knot irritation.
Abstract
Purpose: The purpose of our study was to perform a comparison of the outcomes of the modified Brostrom procedure using only a suture anchor compared with using a suture anchor with a pushlock anchor. Materials and Methods: This was a retrospective study of chronic lateral ankle instability that underwent a modified Brostrom procedure using a bioabsorbable suture anchor & a pushlock anchor, performed by a single surgeon. A total of 88patients were enrolled in the study. The function of the patient’s ankles were scored using the American Orthopaedic Foot and Ankle Society (AOFAS), visual analogue scale (VAS) both preoperatively and postoperatively. Results: The difference in the overall means between the group A and group B was not statistically significant. But, the patient’s satisfaction was better in the group B, and there were more complications in the group A. Conclusion: The technique presented here uses the modified Brostrom procedure with pushlock anchors to prevent the problems associated with subcutaneous knot irritation.
참고문헌 (14)
- Baumhauer JF, "Surgical considerations in the treatment of ankle instability", J Athl Train, 37, pp.458~462 (2002)
- Ferkel RD, "Chronic lateral instability : arhroscopic findings and long-term results", Foot Ankle Int, 28, pp.24~31 (2007)
- Garrick JG, "The frequency of injury, mechanism of injury and epidemiology of ankle sprain", Am J Sports Med, 5, pp.241~242 (1977)
- 이진영, "봉합 나사를 이용한 변형 Bröstrom 술식 및 관절경 검사를 이용한 족관절 외측 불안정성의 치료", 대한족부족관절학회지, 13(2), pp.175~178 (2009), 대한족부족관절학회
- Coughlin MJ, "Comprehensive reconstruction of the lataeral ankle for chronic instability using a free gracilis graft", Foot Ankle Int, 25, pp.231~241 (2004)
- Freeman MA, "Instability of the foot after injuries to the lateral ligament of the ankle", J Bone Joint Surg Br, 47, pp.669~677 (1965)
- Harrington KD, "Degenerative arthritis of the ankle secondary to long-standing lateral ligament instability", J bone Joint Surg Am, 61, pp.354~361 (1979)
- Chrisman OD, "An experimental study and clinical evaluation os seven patients treated by a new modification of the Elmslie procedure", J bone Joint Surg Am, 51, pp.904~912 (1969)
- Elmslie RC, "Recurrent subluxations of the ankle joint", Ann Surg, 100, pp.364~367 (1934)
- Evans DL, "Recurrent instability of the ankle; a method of surgical treatment", Proc R Soc Med, 46, pp.343~344 (1953)
- Brostrom L., "Sprained ankles. VI. Surgical treatment of chronic ligament ruptures", Acta Chir Scand, 132, pp.551~565 (1966)
- Messer TM, "Outcome of the modified Brostrom procedure for chronic lateral ankle instability using suture anchors", Foot Ankle Int, 21, pp.996~1003 (2000)
- Karlsson J, "Reconstruction of the lateral ligaments of the ankle for chronic lateral instability", J Bone Joint Surg Am, 70, pp.581~588 (1988)
- Wieser K, "Suture slippage in knotless suture anchors as a potential failure mechanism in rotator cuff repair", Arthroscopy, 11, pp.1622~1627 (2012)