Purpose: The purpose of this study was to analyze the clinical results of application of bioabsorbable screws in hallux valgus surgery using modified Mau osteotomy. Materials and Methods: We retrospectively reviewed medical records of 25 patients. Operations were performed between May 2013 and January 2014. We performed 33 modified Mau osteotomies and fixed using bioabsorbable screws. Mean age of patients was 52 years (range 19 to 71). Mean follow up duration was 13.2 months (range 12.3 to 18.9). The clinical evaluations included pain visual analogue scale (VAS) score, American Orthopaedic Foot and Ankle Society (AOFAS) score, and satisfaction score. Weight bearing anteroposterior radiographs were taken for measurement of hallux valgus angle (HVA), intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA). All radiographs were evaluated in order to detect complications related to bioabsorbable screws such as osteolysis, cyst formation, and fixation failure. Results: The mean pre- and postoperative pain VAS scores were 4.0 and 1.7 (p<0.05). The mean AOFAS score improved from 52.6 to 82.8 (p<0.05). Preoperative HVA and IMA were 31.2 and 13.9, respectively. Postoperative HVA and IMA were 5.2 and 6.2 (p<0.05). The DMAA increased from 7.8 to 9.9 (p<0.05). There was one case of superficial wound infection and one loss of correction, and no case of osteolysis, cystic formation around the screw, or deep infection. All patients showed union without fixation failure. Conclusion: The clinical and radiological evaluation of this study demonstrates reliable results without fixation failure or allergic reaction. The use of bioabsorbable screw appears not to be inferior to metal screw fixation in hallux valgus surgery.
Abstract
Purpose: The purpose of this study was to analyze the clinical results of application of bioabsorbable screws in hallux valgus surgery using modified Mau osteotomy. Materials and Methods: We retrospectively reviewed medical records of 25 patients. Operations were performed between May 2013 and January 2014. We performed 33 modified Mau osteotomies and fixed using bioabsorbable screws. Mean age of patients was 52 years (range 19 to 71). Mean follow up duration was 13.2 months (range 12.3 to 18.9). The clinical evaluations included pain visual analogue scale (VAS) score, American Orthopaedic Foot and Ankle Society (AOFAS) score, and satisfaction score. Weight bearing anteroposterior radiographs were taken for measurement of hallux valgus angle (HVA), intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA). All radiographs were evaluated in order to detect complications related to bioabsorbable screws such as osteolysis, cyst formation, and fixation failure. Results: The mean pre- and postoperative pain VAS scores were 4.0 and 1.7 (p<0.05). The mean AOFAS score improved from 52.6 to 82.8 (p<0.05). Preoperative HVA and IMA were 31.2 and 13.9, respectively. Postoperative HVA and IMA were 5.2 and 6.2 (p<0.05). The DMAA increased from 7.8 to 9.9 (p<0.05). There was one case of superficial wound infection and one loss of correction, and no case of osteolysis, cystic formation around the screw, or deep infection. All patients showed union without fixation failure. Conclusion: The clinical and radiological evaluation of this study demonstrates reliable results without fixation failure or allergic reaction. The use of bioabsorbable screw appears not to be inferior to metal screw fixation in hallux valgus surgery.
참고문헌 (13)
- Mau C, "Die operative Behandlung des Hallux valgus(Nachuntersuchungen)", Deutsche Zeitschrift für Chirurgie, 197, pp.361~377 (1926)
- Bae SY, "Modified mau osteotomy for the treatment of severe hallux valgus", J Korean Foot Ankle Soc, 8, pp.117~120 (2004)
- Robinson AH, "Modern concepts in the treatment of hallux valgus", J Bone Joint Surg Br, 87, pp.1038~1045 (2005)
- Stamatis ED, "Strength of fixation of Ludloff metatarsal osteotomy utilizing three different types of Kirschner wires : a biomechanical study", Foot Ankle Int, 24, pp.805~811 (2003)
- Unal AM, "Comparison of screwfixation stabilities of first metatarsal shaft osteotomies : a biomechanical study", Acta Orthop Traumatol Turc, 44, pp.70~75 (2010)
- Böstman OM, "Absorbable implants for the fixation of fractures", J Bone Joint Surg Am, 73, pp.148~153 (1991)
- Gill LH, "Fixation with bioabsorbable pins in chevron bunionectomy", J Bone Joint Surg Am, 79, pp.1510~1518 (1997)
- Barber FA, "Sutures and suture anchors--update 2006", Arthroscopy, 22(1063), pp.e1~9
- Böstman OM, "Adverse tissue reactions to bioabsorbable fixation devices", Clin Orthop Relat Res, 371, pp.216~227 (2000)
- Hirvensalo E, "Chevron osteotomy fixed with absorbable polyglycolide pins", Foot Ankle, 11, pp.212~218 (1991)
- Deorio JK, "Single absorbable polydioxanone pin fixation for distal chevron bunion osteotomies", Foot Ankle Int, 22, pp.832~835 (2001)
- Small HN, "Fixation of the Chevron osteotomy utilizing absorbable polydioxanon pins", Foot Ankle Int, 16, pp.346~350 (1995)
- Winemaker MJ, "Comparison of bioabsorbable pins and Kirschner wires in the fixation of chevron osteotomies for hallux valgus", Foot Ankle Int, 17, pp.623~628 (1996)