본문 바로가기
KERD
논문KCI 등재

작업 강도가 방진 마스크의 밀착도와 감성품질에 미치는 영향

Effect of Work Intensity on Fit Factor and Affecive Quality of Dustproof Mask

0

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류학제간연구

초록

Purpose: The purpose of this study is to investigate the effect of work intensity on fit factor and affective quality of the dustproof Mask Background: Among the victims who suffer pneumoconiosis due to the inhalation of toxic substances or the lack of oxygen during the work, the proportion of the victims is larger than the other causes. Wearing a respirator may prevent pneumoconiosis, but it can be hazardous to workers because of the leakage through filters, cartridges, exhaust valves, broken parts, and face-to-face contact. Despite leakage through the contact area between the mask and the face has various causes such as the wearer's activity, sweat accumulation, facial shape, etc., There is a lack of relevant research and regulation compared to developed countries that have already institutionalized the law 30 years ago and give the right to sell through a test Method: The work intensity was adjusted by walking or running at 6km/h and 11km/h on the treadmill, and tasks were defined with reference to the test procedure and the exercise sequence applied in the face leakage test of the dustproof mask. And fit factor was measured objectively using ‘Respirator Fit Tester 8038’ which measures fit factor calculated by dividing the number of dust present outside the mask by inside the mask. In addition, affective quality was classified by the ease of use, ease of breathing, and ease of wearing, and was measured using the 5-point likert scale questionnaire. Results: There was a significant difference in fit factor, ease of breathing, and wearing convenience according to work intensity and no significant difference in ease of use(α=0.01). And when the work intensity was high, fit factor, ease of breathing, and wearing convenience were all lower than when the work intensity was low. Conclusion: In Korea, it is necessary to consider consideration of the work intensity when testing the leakage rate of the face part for safety certification of the respiratory protective equipment, When developing a mask, it should be possible to maintain high adhesion even under intense, active situation and high temperature conditions by selecting materials, improving the wearing style, and expanding the adjustable range.

Abstract

Purpose: The purpose of this study is to investigate the effect of work intensity on fit factor and affective quality of the dustproof Mask Background: Among the victims who suffer pneumoconiosis due to the inhalation of toxic substances or the lack of oxygen during the work, the proportion of the victims is larger than the other causes. Wearing a respirator may prevent pneumoconiosis, but it can be hazardous to workers because of the leakage through filters, cartridges, exhaust valves, broken parts, and face-to-face contact. Despite leakage through the contact area between the mask and the face has various causes such as the wearer's activity, sweat accumulation, facial shape, etc., There is a lack of relevant research and regulation compared to developed countries that have already institutionalized the law 30 years ago and give the right to sell through a test Method: The work intensity was adjusted by walking or running at 6km/h and 11km/h on the treadmill, and tasks were defined with reference to the test procedure and the exercise sequence applied in the face leakage test of the dustproof mask. And fit factor was measured objectively using ‘Respirator Fit Tester 8038’ which measures fit factor calculated by dividing the number of dust present outside the mask by inside the mask. In addition, affective quality was classified by the ease of use, ease of breathing, and ease of wearing, and was measured using the 5-point likert scale questionnaire. Results: There was a significant difference in fit factor, ease of breathing, and wearing convenience according to work intensity and no significant difference in ease of use(α=0.01). And when the work intensity was high, fit factor, ease of breathing, and wearing convenience were all lower than when the work intensity was low. Conclusion: In Korea, it is necessary to consider consideration of the work intensity when testing the leakage rate of the face part for safety certification of the respiratory protective equipment, When developing a mask, it should be possible to maintain high adhesion even under intense, active situation and high temperature conditions by selecting materials, improving the wearing style, and expanding the adjustable range.

참고문헌 (17)

  1. Arthur T. Johnson, "Individual Work Performance During a 10-Hour Period of Respirator Wear", American Industrial Hygiene Association Journal, 58(5), pp.345~353 (1997)[DOI]
  2. Bergman, M. S., "Development of an Advanced Respirator Fit-Test Headform", Journal of Occupational and Environmental Hygiene, 11(2), pp.117~125 (2014)[DOI]
  3. Canadian Standards Association, "Z94.4-93: Selection, use and care of respirators", ~ (1993)
  4. Caretti DM., "Respirator fit factor performance while sweating", American Industrial Hygiene Association Journal, 60(1), pp.84~88 (1999)[DOI]
  5. David Claudio, "Perceived Usefulness and Ease of Use of Wearable Sensor-Based Systems in Emergency Departments", IIE Transactions on Occupational Ergonomics and Human Factors, 3(3-4), pp.177~187 (2015)[DOI]
  6. 한돈희, "검정실험 TIL(누설률)에 의한 방진마스크의 평가와 TIL의 적합성에 관한 연구", 한국산업보건학회지, 14(3), pp.213~220 (2004), 한국산업보건학회
  7. Don-Hee Han, "Fit Testing for Respirators and Development of Anthropometric Test Panels", Journal of Korean Society of Occupational Environmental Hygiene, 9(1), pp.1~13 (1999)
  8. Jessica Hauge, "Real-time fit of a respirator during simulated health care tasks", Journal of Occupational and Environmental Hygiene, 9(10), pp.563~571 (2012)[DOI]
  9. 이정희, "자석 트레드밀과 일반 트레드밀 운동 시 에너지대사량 및 젖산농도 비교", 한국체육과학회지, 23(2), pp.969~992 (2014), 한국체육과학회
  10. Jung-Hyun Kim, "Physiologic and fit factor profiles of N95 and P100 filtering facepiece respirators for use in hot, humid environments", American Journal of Infection Control, 44(2), pp.194~198 (2016)[DOI]
  11. Kolesar ES Jr, "Comparison of respirator protection factors measured by two quantitative fit test methods", Aviation, Space and Environmental Medicine, 53(11), pp.1116~1122 (1982)
  12. Korea Occupational Safety & Health Agency, "2017 Survey of occupational accidents and diseases" (2018)
  13. Min Cheol Kim, "Development and Performance Evaluation of Air-Supplied Mask", Clean Technology, 4(1), pp.60~67 (1998)
  14. Ministry of Employment and Labor., "Notification of the Safety Certification about Protective Equipment", ~ (2017)
  15. National Institute for Occupational Safety and Health, "Guide to industrial respiratory protection. DHHS", NIOSH Pub. No. 87-116, 1987
  16. Roberge RJ, "Protective facemask impact on human thermoregulation: an overview", The Annals of Occupational Hygiene, 56(1), pp.102~112 (2012)
  17. 홍영기, "코로나 방전에 의한 방진", 의료용 마스크 여과재의 기능화 가공, 2013, pp.25(3), 232~239[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (11건)