습도 변화에 따른 에어로졸의 농도 및 크기의 변화경향 파악
Change of the Size-Resolved Aerosol Concentration Due to Relative Humidity
1
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
In this study, the atmospheric aerosol concentration measured at different relative humidity levels was analyzed. Using an optical particle counter, PM10 and PM2.5 concentration as well as particle size distribution were measured and the relation between these size resolved data and relative humidity was studied. The results showed that mass concentration increases as relative humidity increases. The comparison between PM1, PM2.5 and PM10 showed that the fine particles grow more than coarse particles as relative humidity increases. The results also showed that PM10-2.5 and relative humidity do not show close correlation, which means that the mass increase of PM10 at high relative humidity is mainly due to the growth of PM2.5.
Abstract
In this study, the atmospheric aerosol concentration measured at different relative humidity levels was analyzed. Using an optical particle counter, PM10 and PM2.5 concentration as well as particle size distribution were measured and the relation between these size resolved data and relative humidity was studied. The results showed that mass concentration increases as relative humidity increases. The comparison between PM1, PM2.5 and PM10 showed that the fine particles grow more than coarse particles as relative humidity increases. The results also showed that PM10-2.5 and relative humidity do not show close correlation, which means that the mass increase of PM10 at high relative humidity is mainly due to the growth of PM2.5.
참고문헌 (14)
- Burkart,J., "Characterizing the performance of two optical particle counters(Grimm OPC1.108 and OPC1.109) under urban aerosol conditions", Journal of Aerosol Science, 41, pp.953~962
- Chang, C.T., "A model for the relative humidity effect on the readings of the PM-10 beta gauge monitor", Journal of Aerosol Science, 34, pp.1685~1697 (2003)
- Chang, C.T., "Differences in PM-10 concentrations measured by beta gauge monitor and high-vol sampler", Atmospheric Environment, 35, pp.5741~5748 (2001)
- 정창훈, "OPC(광학적 입자 계수기)로 측정한 2001년 서울지역 에어로졸의 입경 분포", 한국대기환경학회지, 19(5), pp.515~528 (2003), 한국대기환경학회
- 정창훈, "광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸특성", 한국환경과학회지, 14(6), pp.565~575 (2005), 한국환경과학회
- 정창훈, "비교 측정을 통한 PM-10 질량농도의 오차 분석", 한국대기환경학회지, 23(6), pp.689~698 (2007), 한국대기환경학회
- Jung, C. H., "Comparison of the PM-10 mass concentration in different measurement methods and meteorological conditions", Particle and Aerosol Research, 5(2), pp.53~62 (2009)
- 정창훈, "비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석", 환경영향평가, 19(4), pp.431~441 (2010), 한국환경영향평가학회
- 김두용, "TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교", PARTICLE AND AEROSOL RESEARCH, 8(1), pp.9~15 (2012), 한국입자에어로졸학회
- Lee, Seung Ha, "The relationship between the estimated water content and water soluble organic carbon", 석사, pp.2012
- Analysis of fine particles in metropolitan area and estimation of secondary particle formation, "NIER", Research Report, National Institute of Environmental Research, ~ (2008)
- Shin, S. E., "Analysis of the measurement difference for the PM10 concentrations between Beta-ray absorption and gravimetric methods at Gosan", Aerosol and Air Quality Research, 11(7), pp.846~853 (2011)
- Shin, S. E., "Estimation of the optimal heated inlet air temperature for the beta-ray absorption method: analysis of the PM10 concentration difference by different methods in coastal areas", Advances in Environmental Research, 1(1), pp.69~82 (2012)
- Tsai, C.J., "Comparison of two ambient beta gauge PM-10 samplers", JAWM & A, 46, pp.142~147 (1996)