This paper reports that the installation of a carbon fiber ionizer in front of an activated carbon fiber(ACF) filter enhanced the antibacterial efficiency. In addition, the effect of the ionizer on the filtration of bioaerosols is reported. Negative air ions from the ionizer were used as antibacterial agent. The test bacteria(Escherichia coli) were aerosolized using an atomizer and were deposited on the ACF filter media for 10 minutes. E. coli deposited on the filter were exposed to negative air ions for 0, 1, 5 and 10 minutes. Then they were separated from the ACF filter by shaking incubation with nutrient broth for 4 hours. The separated E. coli were spread on nutrient agar plates and incubated at 37℃ for 1~3 days. The antibacterial efficiency of E. coli was measured using a colony counting method. The antibacterial efficiencies of E. coli exposed to negative air ions for 1, 5 and 10 minutes were 14%, 48% and 71%,respectively. The filtration efficiency was evaluated by measuring the number concentration of bioaerosols at the upstream and downstream of the filter media. The increase of filtration efficiency by air ions was 14%, that is similar to the 17% filtration efficiency by none air ions. The ozone concentration was below the detection limit (under 0.01ppm) when the carbon fiber ionizers were on.
Abstract
This paper reports that the installation of a carbon fiber ionizer in front of an activated carbon fiber(ACF) filter enhanced the antibacterial efficiency. In addition, the effect of the ionizer on the filtration of bioaerosols is reported. Negative air ions from the ionizer were used as antibacterial agent. The test bacteria(Escherichia coli) were aerosolized using an atomizer and were deposited on the ACF filter media for 10 minutes. E. coli deposited on the filter were exposed to negative air ions for 0, 1, 5 and 10 minutes. Then they were separated from the ACF filter by shaking incubation with nutrient broth for 4 hours. The separated E. coli were spread on nutrient agar plates and incubated at 37℃ for 1~3 days. The antibacterial efficiency of E. coli was measured using a colony counting method. The antibacterial efficiencies of E. coli exposed to negative air ions for 1, 5 and 10 minutes were 14%, 48% and 71%,respectively. The filtration efficiency was evaluated by measuring the number concentration of bioaerosols at the upstream and downstream of the filter media. The increase of filtration efficiency by air ions was 14%, that is similar to the 17% filtration efficiency by none air ions. The ozone concentration was below the detection limit (under 0.01ppm) when the carbon fiber ionizers were on.
참고문헌 (18)
- Brown, R. C., "Air filtration" (1993), PergamonPress
- Byeon, J.H, "Chracteristics of electroless copper-deposited activated carbon fibers for antibacterial action and adsorption-desorption of volatile organic compounds", Carbon, 45, pp.2307~2320 (2007)
- Fischer, G, "Speices-specific production of microbial volatile organic compounds(MVOC) by airborne fungi from a compost facility", Chemosphere, 39(5), pp.795~810 (1999)
- Fletcher, L. A., "Bactericidal action of positive and negative ions in air, BMC Microbiology", BMC Microbiology, 7, pp.32~ (2007)
- Huang, R, "Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions", Indoor Air, 18, pp.106~112 (2008)
- Huertas, M. L., "Measurement of mobility and mass of atmospheric ions", J. Aerosol Science, 2, pp.145~150 (1971)
- Hunt, N.K, "Inactivation of Escherichia coli with ozone : chemical and inactivation kinetics", Water Research, 33(11), pp.2633~2641 (1999)
- Kim, B.J, "Antibacterial behavior od transition-metals-decorated activated carbon fibers", Journal of Colloid and Interface Science, 325, pp.297~299 (2008)
- 김상국, "활성탄소섬유 흡착bed에서의 톨루엔 흡착특성", 한국대기환경학회지, 24(2), pp.220~228 (2008), 한국대기환경학회
- Kim, Y.S, "Application of air ions for bacterial de-colonization in air filters contaminated by air borne bacteria; Mechanism involved in antibacterial action of air ions", 석사, pp.2010
- Lee, B.U, "Effect of relative humidity and variation of particle number size distribution on the inactivation effectiveness of airborne silver nanoparticles against bacteria bioaerosols deposited on a filter", J. Aerosol Science, 41, pp.447~456 (2010)
- Oh, W.C, "Physical properties and biological effects of activated carbon fibers treated with the herbs", Carbon, 41, pp.1737~1742 (2003)
- 박재홍, "Removal of submicron aerosol particles and bioaerosols using carbon fiber ionizer assisted fibrous medium filter media", Journal of Mechanical Science and Technology, 23(7), pp.1846~1851 (2009), 대한기계학회
- Park, S.J, "Preparation and chracterization of activated carbon fibers supported with silver metal for antibacterial behavior", Journal of colloid and interface science, 261, pp.238~243 (2003)
- Yang, R. T., "Adsorbents: Fundamentals and applications", pp.104~109 (2003), John wiley & Sons, Inc
- Yoon, K.Y, "Bioaerosol removal characteristics of electroless silver-plated activated carbon fiber filters", Journal of Korean Society for Indoor Environment, 3(2), pp.141~149 (2006)
- Yoon, K. Y., "Antimicrobial effect of silver particles on bacterial contamination of activated carbon fibers", Environ. Sci. Tech, 42, pp.1251~1255 (2008)
- 윤기영, "박테리아에 대한 나노 입자의 항균 특성 평가", 한국실내환경학회지, 2(1), pp.46~53 (2005), 한국실내환경학회