APS (Aerodynamic Particle Sizer) and OPC (Optical Particle Counter) have been widely used to real-time measurement of indoor and outdoor aerosols. The APS measures the size distribution based on an aerodynamic diameter, while the OPC uses optical diameter to measure the size distribution of aerosols. Since obtaining a size distribution based on aerodynamic diameter is important to understand aerosol characteristics, lots of researcher had been developed experimental equations which can convert optical diameter into aerodynamic diameter. However, previous studies have conducted repeated experiments on particles having a single diameter. In this study, an experimental method of converting optical diameter into aerodynamic diameter through a single experiment was presented. The collection efficiencies of an axial cyclone were measured using APS and OPC at the same time, and the correlation equation between aerodynamic diameter and optical diameter was driven through a theoretical model. Using the proposed method, the size distribution of NaCl particles measured by OPC showed a high correlation with the size distribution obtained by APS (0.93 of R-squared value). In the tests conducted on ISO A1, A2, and A4 test particles, the converted OPC size distribution tended to be similar to the APS size distribution, and for each of test particles (ISO A1, A2, and A4), the R-squared values for the APS particle size distribution were 0.75, 0.86, and 0.89, respectively.

Abstract

APS (Aerodynamic Particle Sizer) and OPC (Optical Particle Counter) have been widely used to real-time measurement of indoor and outdoor aerosols. The APS measures the size distribution based on an aerodynamic diameter, while the OPC uses optical diameter to measure the size distribution of aerosols. Since obtaining a size distribution based on aerodynamic diameter is important to understand aerosol characteristics, lots of researcher had been developed experimental equations which can convert optical diameter into aerodynamic diameter. However, previous studies have conducted repeated experiments on particles having a single diameter. In this study, an experimental method of converting optical diameter into aerodynamic diameter through a single experiment was presented. The collection efficiencies of an axial cyclone were measured using APS and OPC at the same time, and the correlation equation between aerodynamic diameter and optical diameter was driven through a theoretical model. Using the proposed method, the size distribution of NaCl particles measured by OPC showed a high correlation with the size distribution obtained by APS (0.93 of R-squared value). In the tests conducted on ISO A1, A2, and A4 test particles, the converted OPC size distribution tended to be similar to the APS size distribution, and for each of test particles (ISO A1, A2, and A4), the R-squared values for the APS particle size distribution were 0.75, 0.86, and 0.89, respectively.

참고문헌 (15)

  1. Binnig, J., "Calibration of an optical particle counter to provide PM2. 5 mass for well-defined particle materials", Journal of aerosol science, 38(3), pp.325~332 (2007)[DOI]
  2. Chien, C. H., "Upon correlating diameters measured by optical particle counters and aerodynamic particle sizers", Journal of Aerosol Science, 101, pp.77~85 (2016)[DOI]
  3. Duan, H., "A new monodisperse droplet generator and its applications", ILASS Americas 28th Annual Conference on Liquid Atomization and Spray Systems (2016)
  4. Heyder, J., "Optimization of response functions of light scattering instruments for size evaluation of aerosol particles", Applied Optics, 18(5), pp.705~711 (1979)[DOI]
  5. Heim, M., "Performance evaluation of three optical particle counters with an efficient"multimodal"calibration method", Journal of aerosol science, 39(12), pp.1019~1031 (2008)[DOI]
  6. Hand, J. L., "A new method for retrieving particle refractive index and effective density from aerosol size distribution data", Aerosol Science &Technology, 36(10), pp.1012~1026 (2002)[DOI]
  7. Iozia, D. L., "The logistic function and cyclone fractional efficiency", Aerosol Science and Technology, 12(3), pp.598~606 (1990)[DOI]
  8. Kulkarni, P., "Aerosol measurement: principles, techniques, and applications" (2011), John Wiley & Sons
  9. 김두용, "TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교", PARTICLE AND AEROSOL RESEARCH, 8(1), pp.9~15 (2012), 한국입자에어로졸학회
  10. Lapple, C. E., "Gravity and centrifugal separation", American Industrial Hygiene Association Quarterly, 11(1), pp.40~48 (1950)[DOI]
  11. Li, E., "A new collection theory of cyclone separators", AIChE Journal, 35(4), pp.666~669 (1989)[DOI]
  12. Matsoukas, T., "Charge distributions in bipolar particle charging", Journal of aerosol science, 25(4), pp.599~609 (1994)[DOI]
  13. Mitchell, J. P., "Time-offlight aerodynamic particle size analyzers : their use and limitations for the evaluation of medical aerosols", Journal of aerosol medicine, 12(4), pp.217~240 (1999)[DOI]
  14. Sang-Nourpour, N., "Calibration of optical particle counters with an aerodynamic aerosol classifier", Journal of Aerosol Science, 138, pp.105452~ (2019)[DOI]
  15. Volckens, J., "Counting and particle transmission efficiency of the aerodynamic particle sizer", Journal of Aerosol (2005)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (4건)