Study for Residue Analysis of Fluxametamid in Food Matrix
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
BACKGROUND: Accurate and simple analytical method determining Fluxametamid residue was necessary in various food matrices. Additionally, fulfilment of the international guideline of Codex (Codex Alimentarius Commission CAC/GL 40) was required for the analytical method. In this study, we developed Liquid Chromatography- Tandem Mass Spectrometry (LC-MS/MS) method to determine the Fluxametamid residue in foods. METHODS AND RESULTS: Fluxametamid was extracted with acetonitrile, partitioned and concentrated with dichloromethane. To remove the interferences, silica SPE cartridge was used before LC-MS/MS (Liquid Chromatography-Tandem Mass Spectrometry) analysis with C18 column. Five a gricultural commodities (mandarin, potato, soybean, hulledrice, and chilli pepper) were used as a group representative to verify the method. The liner matrix-matched calibration curves were confirmed with coefficient of determination (r2) greater than 0.99 at calibration range of 0.02-2.5 mg/kg. The limits of detection and quantification were 0.001 and 0.005 mg/kg, respectively. Mean average accuracies were shown to be 82.24-115.27%. The precision was also shown to be less than 9.54% for all five samples. CONCLUSION: The method investigated in this study was suitable to the Codex guideline for the residue analysis. Thus, this method can be useful for determining the residue in various food matrices as routine analysis.
Abstract
BACKGROUND: Accurate and simple analytical method determining Fluxametamid residue was necessary in various food matrices. Additionally, fulfilment of the international guideline of Codex (Codex Alimentarius Commission CAC/GL 40) was required for the analytical method. In this study, we developed Liquid Chromatography- Tandem Mass Spectrometry (LC-MS/MS) method to determine the Fluxametamid residue in foods. METHODS AND RESULTS: Fluxametamid was extracted with acetonitrile, partitioned and concentrated with dichloromethane. To remove the interferences, silica SPE cartridge was used before LC-MS/MS (Liquid Chromatography-Tandem Mass Spectrometry) analysis with C18 column. Five a gricultural commodities (mandarin, potato, soybean, hulledrice, and chilli pepper) were used as a group representative to verify the method. The liner matrix-matched calibration curves were confirmed with coefficient of determination (r2) greater than 0.99 at calibration range of 0.02-2.5 mg/kg. The limits of detection and quantification were 0.001 and 0.005 mg/kg, respectively. Mean average accuracies were shown to be 82.24-115.27%. The precision was also shown to be less than 9.54% for all five samples. CONCLUSION: The method investigated in this study was suitable to the Codex guideline for the residue analysis. Thus, this method can be useful for determining the residue in various food matrices as routine analysis.
참고문헌 (7)
- 안경근, "HPLC-UVD", MS를 이용한 농산물 중 Amisulbrom의 잔류분석, 2014, pp.18(4), 321~329[DOI]
- Asahia, M., "Fluxametamide : A novel isoxazoline insecticide that acts via distinctive antagonism of insect ligand-gated chloride channels", Pesticide Biochemistry and Physiology, 151, pp.67~72 (2018)
- Bloomquist, J. R., "Chloride channels as tools for developing selective insecticides", Archives of Insect Biochemistry and Physiology, 54(4), pp.145~156 (2003)
- Kagami, T., "Studies on a novel insecticide, fluxametamide (Part2) Biological activity", Abstract Annual Meeting Pesticide Science Society, pp.83~ (2017)
- 이수진, "GC-ECD", MS를 이용한 농산물 중 captan, folpet, captafol 및chlorothalonil의 잔류분석법, 2010, pp.29(2), 165~175[DOI]
- Ozoe, Y., "The antiparasitic isoxasoline A1443 is a potent blocker of insect ligand-gated chloride channels", Biochemical Biophysical Research Communications, 391(1), pp.744~749 (2010)
- avermectin, "Jounral of Agricultural and Food Chemistry", 2014, 1019~1024