Clogging Potential in Constructed Vertical Flow Wetlands Employing Different Filter Materials for First-flush Urban Stormwater Runoff Treatment
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The function of vertical subsurface flow wetlands can potentially be reduced with time due to clogging and are often assumed to be occurring when ponding and overflow is observed during rainfall. To investigate their clogging potential, three pilot-scale vertical subsurface flow (VSF) wetland systems were constructed employing woodchip, pumice, and volcanic gravel as main media. The systems received stormwater runoff from a highway bridge for seven months, after which the media were taken out and divided into layers to determine the amount and characteristics of the accumulated clogging matters. Findings revealed that the main clogging mechanism was the deposition of suspended solids. This is followed by the growth of biofilm in the media which is more evident in the wetland employing woodchip. Up to more than 30% of the clogging matter were found in the upper 20 cm of the media suggesting that this layer will need replacement once clogging occurs. Moreover, no signs of clogging were observed in all the wetlands during the operation period even though an estimation of at least 2 months without clogging was calculated. This was attributed to the intermittent loading mode of operation that gave way for the decomposition of organic matters during the resting period and potentially restored the pore volume.
Abstract
The function of vertical subsurface flow wetlands can potentially be reduced with time due to clogging and are often assumed to be occurring when ponding and overflow is observed during rainfall. To investigate their clogging potential, three pilot-scale vertical subsurface flow (VSF) wetland systems were constructed employing woodchip, pumice, and volcanic gravel as main media. The systems received stormwater runoff from a highway bridge for seven months, after which the media were taken out and divided into layers to determine the amount and characteristics of the accumulated clogging matters. Findings revealed that the main clogging mechanism was the deposition of suspended solids. This is followed by the growth of biofilm in the media which is more evident in the wetland employing woodchip. Up to more than 30% of the clogging matter were found in the upper 20 cm of the media suggesting that this layer will need replacement once clogging occurs. Moreover, no signs of clogging were observed in all the wetlands during the operation period even though an estimation of at least 2 months without clogging was calculated. This was attributed to the intermittent loading mode of operation that gave way for the decomposition of organic matters during the resting period and potentially restored the pore volume.
참고문헌 (14)
- Bavor HJ, "Constructed Wetlands for Water Quality Improvement", pp.646~656 (1993), Lewis Publishers
- Blazejewski R, "Soil clogging phenomena in constructed wetlands with subsurface flow", Water Science and Technology, 35(5), pp.183~188 (1997), IWA Publishing[DOI]
- Bouwer, H, "Artificial recharge of groundwater: Hydrogeology and engineering", Hydrogeology Journal, 10(1), pp.121~142 (2002)[DOI]
- G.F. Hua, "Clogging pattern in vertical-flow constructed wetlands: Insight from a laboratory study", Journal of Hazardous Materials, 180(1-3), pp.668~674 (2010), Elsevier BV[DOI]
- Kadlec, R, "Treatment Wetlands" (2009), CRC Press, Inc.
- Langergraber, G, "Evaluation of substrate clogging processes in vertical flow constructed wetlands", Water Science and Technology, 48(5), pp.25~34 (2003)
- Larmet, H, "Bacteria and heavy metals concomitant transfer in an infiltration basin: Columns study under realistic hydrodynamical conditions", Proceedings of the NOVATECH 2007: 6th International Conference on Sustainable Techniques and Strategies in Urban Water Management, pp.615~622 (2007)
- Le Coustumer, S, "The influence of design parameters on clogging of stormwater biofilters: A large-scale column study", Water Research, 46(20), pp.6743~6752 (2012)[DOI]
- Houng Li, "Urban Particle Capture in Bioretention Media. II: Theory and Model Development", Journal of Environmental Engineering, 134(6), pp.419~432 (2008), American Society of Civil Engineers (ASCE)[DOI]
- Platzer C, "Soil clogging in vertical flow reed beds mechanisms, parameters, consequences and.......solutions?", Water Science and Technology, 35(5), pp.175~182 (1997), IWA Publishing[DOI]
- Winter, KJ, "The impact of sewage composition on the soil clogging phenomena of vertical flow constructed wetlands", Water Science and Technology, 48(5), pp.9~14 (2003)
- C.F. Yong, "Predicting physical clogging of porous and permeable pavements", Journal of Hydrology, 481, pp.48~55 (2013), Elsevier BV[DOI]
- Y.Q Zhao, "Anti-sized reed bed system for animal wastewater treatment: a comparative study", Water Research, 38(12), pp.2907~2917 (2004), Elsevier BV[DOI]