In previous study, volatile organic compounds (VOCs) emission characteristics were highly affected by coating materials for wood finishing. Natural based coating materials showed that about 15~46% lower TVOC emission than typical products. In this study, long-term changes of VOCs emission characteristics from pine panel with three types of coating treatments were determined. Non-treated pine panel emitted 604.7 μg/m2⋅h of TVOC that contained 66% of NVOC (399.7 μg/m2⋅h) at 0 month. After 10 month, TVOC reduced 88% and 93% reduction on NVOC was observed. Natural oil and waterborne stain treated pine panel showed 61% and 77% lower TVOC, respectively, than non-treated pine panel. However, TVOC from finished pine panels showed higher TVOC emission than non-treated pine panel. All samples satisfied the VOC emission regulation (below 4,000 μg/m2⋅h) by Korean Ministry of Environment. Toluene emission regulation (below 80 μg/m2⋅h) was passed on all sample without varnish treated pine panel at 0 month. According to HB qualification standard for construction materials by Korea Air Cleaning Association (KACA), wood is not qualified to get the best tag due to high TVOC emission. At the 10 months, only non-treated pine panel could get the best tag of HB from KACA.

Abstract

In previous study, volatile organic compounds (VOCs) emission characteristics were highly affected by coating materials for wood finishing. Natural based coating materials showed that about 15~46% lower TVOC emission than typical products. In this study, long-term changes of VOCs emission characteristics from pine panel with three types of coating treatments were determined. Non-treated pine panel emitted 604.7 μg/m2⋅h of TVOC that contained 66% of NVOC (399.7 μg/m2⋅h) at 0 month. After 10 month, TVOC reduced 88% and 93% reduction on NVOC was observed. Natural oil and waterborne stain treated pine panel showed 61% and 77% lower TVOC, respectively, than non-treated pine panel. However, TVOC from finished pine panels showed higher TVOC emission than non-treated pine panel. All samples satisfied the VOC emission regulation (below 4,000 μg/m2⋅h) by Korean Ministry of Environment. Toluene emission regulation (below 80 μg/m2⋅h) was passed on all sample without varnish treated pine panel at 0 month. According to HB qualification standard for construction materials by Korea Air Cleaning Association (KACA), wood is not qualified to get the best tag due to high TVOC emission. At the 10 months, only non-treated pine panel could get the best tag of HB from KACA.

참고문헌 (18)

  1. 국토부, "주택법 제21조 및 주택건설기준 등에 관한 규정 제65조 건강친화형 주택 건설기준 별표 1. 실내공기 오염물질 저방출 건축자재의 적용기준. 국토교통부고시 제2015-998호", ~ (2015)
  2. 김신도, "화학 및 천연페인트에서 발생되는 TVOCs의 방출강도 특성 연구", 한국환경보건학회지, 30(5), pp.487~493 (2004), 한국환경보건학회
  3. 박상범, "목재용 마감도료의 휘발성유기화합물 방출특성", 한국가구학회지, 26(1), pp.22~30 (2015), 한국가구학회
  4. 박상범, "도장처리에 따른 소나무 판재의 휘발성유기화합물 방출특성 변화", 한국가구학회지, 26(2), pp.122~129 (2015), 한국가구학회
  5. 박현주, "목질제품에서 방출되는 휘발성 유기화합물 특성 연구", 한국대기환경학회지, 26(6), pp.616~623 (2010), 한국대기환경학회
  6. 장극관, "환경친화적인 목조주택", 건축, 5, pp.33~36 (2003)
  7. 이희영, "신축목조주택 내 마감자재에 따른 휘발성유기화합물(VOCs)의 방산특성", 목재공학, 35(6), pp.83~90 (2007), 한국목재공학회
  8. 이희영, "신축목조주택의 VOCs 및 포름알데히드 방출특성 비교", 2007 Proceedings of 한국목재공학학회, pp.183~184 (2007)
  9. 이민, "편백잎추출수의 실내 가습시 휘발성유기화합물 방출 특성", 목재공학, 42(6), pp.747~757 (2014), 한국목재공학회
  10. 임정연, "국내 기능성 건축자재의 폼알데하이드 및 톨루엔 흡착성능 평가", 한국실내환경학회지, 9(3), pp.239~249 (2012), 한국실내환경학회
  11. 환경부, "다중이용시설등의 실내공기질 관리법 시행규칙 제3조 별표 2. 실내공기질유지기준. 환경부령,(201)", ~ (2006)
  12. Hoddinott, K. B., "The use of environmental risk assessment methodologies for an indoor air quality investigation", Chemosphere, 41(1), pp.77~84 (2000)
  13. "ISO 16000-9:2006, Indoor air - Part 9: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test chamber method", ~ (2006)
  14. Sheldon, L., "Indoor air quality in public buildings (Vol. 88)" (1988), Office of Acid Deposition, Environmental Monitoring and Quality Assurance, Office of Research and Development, US Environmental Protection Agency
  15. Sundell, J., "On the history indoor air quality and health", Indoor Air, 14, pp.51~48 (2001)
  16. Spengler, J. D., "Indoor air quality handbook", pp.33~ (2001), McGraw-Hill
  17. Yu, B. F., "Review of research on air-conditioning systems and indoor air quality control for human health", International Journal of Refrigeration, 32(1), pp.3~20 (2009)
  18. World Health Organization, "WHO guidelines for indoor air quality: selected pollutants", WHO, ~ (2010)

이 간행물의 다른 논문 (16건)