Polarography is a subclass of voltammetry where the working electrode is a dropping mercury electrode. More, I developed the experiment for raising up mercury electrode. In Voltammetry, information about an analyte is obtained by measuring the current as the potential is varied at oxidation-reduction reaction. A plot of current vs. potential in a polarography experiment shows the current oscillations correspoding to the drops of Hg falling from the capillary. The drops growth causes capacitive and faradic current. These changing current effects combined with experiments where the potential is continuously changed can result in noisy traces. The raising up type improved upon the method of dropping in hardware. In reduction of the noise, moving average smoothing method have been used. But the other procedure is introduced based on Fourier transformation. So FFT and IFFT engine was implemented and installed in my experiment. However, after experimentation, peak height as the measuring parameter gave a good linear relationship to concentration. The resolution of potential peaks of various kinds, using Zn and Cu as the example, was improved using the smoothing method.

Abstract

Polarography is a subclass of voltammetry where the working electrode is a dropping mercury electrode. More, I developed the experiment for raising up mercury electrode. In Voltammetry, information about an analyte is obtained by measuring the current as the potential is varied at oxidation-reduction reaction. A plot of current vs. potential in a polarography experiment shows the current oscillations correspoding to the drops of Hg falling from the capillary. The drops growth causes capacitive and faradic current. These changing current effects combined with experiments where the potential is continuously changed can result in noisy traces. The raising up type improved upon the method of dropping in hardware. In reduction of the noise, moving average smoothing method have been used. But the other procedure is introduced based on Fourier transformation. So FFT and IFFT engine was implemented and installed in my experiment. However, after experimentation, peak height as the measuring parameter gave a good linear relationship to concentration. The resolution of potential peaks of various kinds, using Zn and Cu as the example, was improved using the smoothing method.

참고문헌 (6)

  1. 이재춘, "유리탄소전극과 적상수은전극을 이용한 미량원소측정시스템과그의 전자시스템 및 제어방법, 특허번호 10-0485988", ~ (2005)
  2. C. W. K. Chow, "Signal enhancement of potentiometric stripping analysis using digital signal processing", analytica chimica acta, 307, pp.15~26 (1995)
  3. Bard, Allen J., "Electrochemical Methods, Fundamentals and applications(2 ed)" (2000), Wiley
  4. A. Savitzky, "Signal enhancement of potentiometric stripping analysis", analytica chimica acta, 36, pp.15~26 (1964)
  5. 임제탁, "이산신호처리" (1998), 대영사
  6. 이채욱, "최신 디지털 신호처리" (1999), 북스힐