호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술
Respiratory air flow measuring technique without sensing element on the flow stream
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.
Abstract
Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.
참고문헌 (15)
- 황성오, "심폐소생술 In: 심폐소생술과 전문심장소생술", pp.13~25 (2005), 군자출판사
- 황성오, "기본소생술 In: 심폐소생술과 전문심장소생술", pp.27~62 (2005), 군자출판사
- 사단법인 대한심폐소생협회, "공용 심폐소생술 가이드라인 개발 및 배포", pp.1~18 (2007), 대한심폐소생협회
- TP Aufderheide, "Death by hyperventilation:a common and life -threatening problemduring cardiopulmonary resuscitation", Crit. CareMed., 32(9), pp.S345~S351 (2004)
- 서울아산병원 심폐소생술 위원회, "인공호흡 In: 심폐소생술", pp.21~26 (2006), 군자출판사
- CH Buess, "Pneumotachometers. In:Encyclopedia of medical devices and instrumentation", pp.2319~2324 (1988), John Wiley & Sons
- A. Fleisch, "Der pneumotachography: ein ApparatzurBeischwindgkeitregstrierung der Atemluft", Arch.Ges. Physiol, 209, pp.713~722 (1925)
- Micro Medical Ltd, "MicroLab Operating Manual", pp.2~4 (1998), Micro Medical Ltd
- K. Konno, "Measurement of the seperatrevolume changes of rib cage and abdomenduring breathing", J. Appl. Physiol, 22(3), pp.407~422 (1967)
- 김경아, "호흡 감지를 위한 복부 부착형 전도성 고무소자의 계측특성", 센서학회지, 16(1), pp.24~32 (2007), 한국센서학회
- 이인광, "의복착용형 무선 호흡모니터 시스템", 센서학회지, 17(2), pp.133~142 (2008), 한국센서학회
- 신정철, "기초 유체역학", pp.269~314 (2000), 구민사
- B. S. Abella, "Quality of cardiopulmonaryresuscitation during out-of-hospitalcardiac arrest", JAMA, 293(3), pp.305~310 (2005)
- American Heart Association, "Guidelines for cardiopulmonaryresuscitation emergency cardiovascularcare", Circulation, 102(1), pp.I1~I384 (2000)
- American Thoracic Society, "Standardization ofspirometry", Am. J. Respir. Crit. Care Med., 152, pp.1107~1136 (1995)