GMR센서 배열을 이용한 자석팁의 2D 위치 추정
2D Location Estimation of a Magnetized Tip Using Arrayed GMR Sensors
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This paper proposes a method for estimating the location of a magnetized tip that is inside a non-transparent space or body by using arrayed giant magnetoresistance (GMR) sensors. In general, an object located in such an opaque space can be detected using X-rays, magnetic fields, ultra-sonic sensors, etc., depending on its characteristics. X-ray is mostly used for medical purposes but frequent exposure to it could cause harm to patients as well as doctors. In this study, how well a GMR sensor is applicable instead of an X–ray is investigated. The sensor’s voltage output is experimentally fitted to distance with a relationship of 3rd degree polynomial. To detect a small magnetized tip with 900 Oe inside a human body, a 2×2 arrayed GMR sensor and a location estimation algorithm based on information acquired from four sensors is developed. Evaluation tests show that the suggested method is applicable to limited cases with a distance less than 33–55 mm, and the location of a magnet tip is estimated relatively well with an error less than 1.5 mm.
Abstract
This paper proposes a method for estimating the location of a magnetized tip that is inside a non-transparent space or body by using arrayed giant magnetoresistance (GMR) sensors. In general, an object located in such an opaque space can be detected using X-rays, magnetic fields, ultra-sonic sensors, etc., depending on its characteristics. X-ray is mostly used for medical purposes but frequent exposure to it could cause harm to patients as well as doctors. In this study, how well a GMR sensor is applicable instead of an X–ray is investigated. The sensor’s voltage output is experimentally fitted to distance with a relationship of 3rd degree polynomial. To detect a small magnetized tip with 900 Oe inside a human body, a 2×2 arrayed GMR sensor and a location estimation algorithm based on information acquired from four sensors is developed. Evaluation tests show that the suggested method is applicable to limited cases with a distance less than 33–55 mm, and the location of a magnet tip is estimated relatively well with an error less than 1.5 mm.
참고문헌 (12)
- 강문호, "Zynq-SoC를 이용한 초음파 위치추적 시스템", 전기학회논문지, 66(8), pp.1250~1256 (2017), 대한전기학회
- 이태범, "화물 검색 시스템을 위한 듀얼 에너지 X-ray 검색기 영상을 이용한 물질 추정 방법", 한국산업정보학회논문지, 23(1), pp.1~12 (2018), 한국산업정보학회[DOI]
- 홍동표, "제스처기반 사용자 인터페이스에 대한 연구 동향", Telecommunications Review, 18(3), pp.403~413 (2008), 에스케이텔레콤 (주)
- C. D. Natali, "Real-Time Pose Detection for Magnetic Medical Devices", IEEE Transac. Magn, 49(7), pp.3524~3527 (2013)
- J. Daughton, "Magnetic field sensors using GMR multilayer", IEEE Transac. Magn, 30(6), pp.4608~4610 (1994)
- J. M. Daughton, "GMR applications", J. Magn. Magn. Mater, 192(2), pp.334~342 (1999)
- S. C. Mukhopadhyay, "A Novel Needle-Type SV-GMR Sensor for Biomedical Applications", IEEE Sens. J., 7(3), pp.xx~yy (2007)
- J. Lenz, "Magnetic Sensors and Their Applications", IEEE Sens. J, 6(3), pp.631~649 (2006)
- A. Anguelouch, "Detection of ferromagnetic nanowires using GMR sen-sors", IEEE Transac. Magn, 40(4), pp.2997~2999 (2004)
- V. Schlagetera, "Tracking system with five degrees of freedom using a 2D-array of Hall sensors and a permanent magnet", Sens. Actuators A, 92(1-3), pp.37~42 (2001)
- P. -H. Tichit, "Waveguide taper engineering using coordinate transformation technology", Opt. Express, 18(2), pp.767~772 (2010)
- 권성기, "균등거리비율을 적용한 위치인식 보정 알고리즘 설계 및 성능분석", 한국산학기술학회논문지, 11(4), pp.1248~1253 (2010), 한국산학기술학회