가정용 식품 방사능 모니터링 센서 개발 및 유용성 평가

Development of a Foods Radioactivity Monitoring Sensor for Household and Evaluation of its Effectiveness

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

In this study, a foods radioactivity monitoring sensor was developed as a part of basic research for household radioactivity monitoring, and its performance was evaluated using a calibration source. The prototype of the sensor was based on a CsI:Tl scintillator using a crys- tal light guide and Si photomultiplier. The light guide was introduced to improve gamma-ray detection efficiency. For quantitative eval- uation, tests were conducted using 134Cs liquid source. In the performance evaluation, It was confirmed that analysis of 134Cs: 100 Bq/L(kg) was possible. Thus, result of this study is expected to contribute to research in the development of the household foods radio- activity monitoring system

Abstract

In this study, a foods radioactivity monitoring sensor was developed as a part of basic research for household radioactivity monitoring, and its performance was evaluated using a calibration source. The prototype of the sensor was based on a CsI:Tl scintillator using a crys- tal light guide and Si photomultiplier. The light guide was introduced to improve gamma-ray detection efficiency. For quantitative eval- uation, tests were conducted using 134Cs liquid source. In the performance evaluation, It was confirmed that analysis of 134Cs: 100 Bq/L(kg) was possible. Thus, result of this study is expected to contribute to research in the development of the household foods radio- activity monitoring system

참고문헌 (11)

  1. 박혜민, "수중 내 베타선 모니터링 센서 개발을 위한 기초연구", 센서학회지, 25(5), pp.333~336 (2016), 한국센서학회
  2. 김창종, "국내 시중 유통 수산물에 대한 방사능 농도 조사", 한국식품과학회지, 47(6), pp.789~792 (2015), 한국식품과학회[DOI]
  3. "Korea ministry of food and drug safety"[URL]
  4. 김창규, "REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE", Nuclear Engineering and Technology, 47(4), pp.479~487 (2015), 한국원자력학회
  5. 조우진, "Preliminary Research of CZT Based PET System Development in KAERI", 방사선방어학회지, 41(2), pp.81~86 (2016), 대한방사선방어학회[DOI]
  6. H. M. Park, "Development and performance characteristics of personal gamma spectrometer for radiation monitoring applications", Sensors, 16(6), pp.1~6 (2016)
  7. 홍승한, "베타", 감마 동시 측정용 광섬유 이중 검출기의 개발을 위한 기초연구, 2014, pp.63(2), 284~290[DOI]
  8. H. S. Kim, "Fabrication and performance characteristics of a CsI(Tl)", PIN diode radiation sensor for industrial applications, 2009, pp.67, 1463~1465