동잡음을 가진 PPG 센서에서의 산소포화도 측정 알고리즘
SpO2 Measurement Algorithm for PPG Signal with Motion Artifacts
1
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Pulse oximetry is a non-invasive method for monitoring how much oxygenated hemoglobin is present in the blood. The principle of pulse oximetry is based on the red infrared light adsorption characteristics of oxygenated and deoxygenated hemoglobin. Even through the convenience of a pulse oximeter, its weak signal-to-noise ratio against motion artifacts and low perfusion makes it difficult to be accepted by execs devices. Several researchers have suggested the use of an adaptive noise cancellation (ANC) algorithm. They have demonstrated that ANC is feasible for reducing the effects of motion artifacts. Masimo Corporation developed a discrete saturation transformation (DST) algorithm that uses a reference signal and ANC. In commercial devices, it is very hard to escape it becauseMasimo’s patents are very powerful and a better method is yet to be developed. This study proposes a new method that can measure noise saturation as well as accurate oxygen saturation from signals with high motion artifacts without using ANC and DST. The pro- posed algorithm can extract a normal signal without noise from a signal with motion artifacts. The reference signal from a pulse oximeter simulator was used for the evaluation of our proposed algorithm and achieved good results.
Abstract
Pulse oximetry is a non-invasive method for monitoring how much oxygenated hemoglobin is present in the blood. The principle of pulse oximetry is based on the red infrared light adsorption characteristics of oxygenated and deoxygenated hemoglobin. Even through the convenience of a pulse oximeter, its weak signal-to-noise ratio against motion artifacts and low perfusion makes it difficult to be accepted by execs devices. Several researchers have suggested the use of an adaptive noise cancellation (ANC) algorithm. They have demonstrated that ANC is feasible for reducing the effects of motion artifacts. Masimo Corporation developed a discrete saturation transformation (DST) algorithm that uses a reference signal and ANC. In commercial devices, it is very hard to escape it becauseMasimo’s patents are very powerful and a better method is yet to be developed. This study proposes a new method that can measure noise saturation as well as accurate oxygen saturation from signals with high motion artifacts without using ANC and DST. The pro- posed algorithm can extract a normal signal without noise from a signal with motion artifacts. The reference signal from a pulse oximeter simulator was used for the evaluation of our proposed algorithm and achieved good results.
참고문헌 (16)
- J. G. Webster, "Design of Pulse Oximeters" (1997), Institute of Physics Publishing
- L. G. Lindberg, "Pulse oximeter signal at various blood flow conditions in an in vitro model", Med. Biol. Eng. Comput., 33(1), pp.87~91 (1995)[DOI]
- M. Kuroda, "Undisrupted pulse wave on pulse oximeter display monitor at cardiac arrest in a surgical patient", J. Anesth., 19(2), pp.164~166 (2005)[DOI]
- J. P. de Kock, "Pulse oximetry: Theoretical and experimental models", Med. Biol. Eng. Comput., 31(3), pp.291~300 (1993)[DOI]
- Y. X. Yang, "Computer analysis system of blood oxygen saturation in an animal hypoxia model", Med. Biol. Eng. Comput., 36(3), pp.355~358 (1998)[DOI]
- Y. Mendelson, "Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography", IEEE Trans. Biomed. Eng., 35(10), pp.798~805 (1988)[DOI]
- W. New, "Pulse oximeter monitor, U. S. Patent, 4653498", ~ (1986)
- G. R. Blackwell, "The technology of pulse oximetry", Biomed. Instrum. Tech., 23(3), pp.188~193 (1989)
- J. F. Kelleher, "Pulse Oximetry", J. Clin. Monit., 5(1), pp.37~62 (1989)[DOI]
- P. D. Mannheimer, "Wavelength selection for low-saturation pulse oximetry", IEEE Trans. Biomed. Eng., 44(3), pp.148~158 (1997)[DOI]
- T. Ukawa, "Pulse Oximeter, U. S. Patent, 5355882", ~ (1994)
- "Technical Bulletin #1, Signal Extraction Technology"[URL]
- "Technical Bulletin #3, PVI"[URL]
- H. J. Seo, "Pulse oximetry-based SpO2 and pulse rate detection for mobile health care devices", pp.2008
- B. S. Kim, "Motion artifact reduction in photoplethysmography using independent component analysis", IEEE Trans. Biomed. Eng., 53(3) (2006)
- K. K. Tremper, "Pulse oximetry and oxygen transform" (1986), Springer-Verlag