This paper relates to a technology for monitoring a liquefied gas storage tank in the special gas field where demand is increasing owing to the continuous growth of related fields such as the semiconductor, display, and ICT convergence electronics industries. We have proposed a system for real - time monitoring using wireless sensor network technology, and implemented a system consisting of a sensor unit, transmitter module, and receiver module to be attached to a liquefied gas storage tank. The system was applied to LCO2tanks among various liquefied gas storage tanks to verify the feasibility. The storage tanks employed in the experiments has capacitiesof 16,179 l and was 1,920 mm in inner diameter. Furthermore, the density was 1.03 g/l. The measured data were compared with ref- erence data on the remaining gas level versus the CO2 height of the surface, expressed using a conventional water meter, provided by an existing storage tank supplier. The experimental results show that the data is similar to the standard data provided by the tank supplier, and has a high accuracy and reliability within an error range of 0.03%.

Abstract

This paper relates to a technology for monitoring a liquefied gas storage tank in the special gas field where demand is increasing owing to the continuous growth of related fields such as the semiconductor, display, and ICT convergence electronics industries. We have proposed a system for real - time monitoring using wireless sensor network technology, and implemented a system consisting of a sensor unit, transmitter module, and receiver module to be attached to a liquefied gas storage tank. The system was applied to LCO2tanks among various liquefied gas storage tanks to verify the feasibility. The storage tanks employed in the experiments has capacitiesof 16,179 l and was 1,920 mm in inner diameter. Furthermore, the density was 1.03 g/l. The measured data were compared with ref- erence data on the remaining gas level versus the CO2 height of the surface, expressed using a conventional water meter, provided by an existing storage tank supplier. The experimental results show that the data is similar to the standard data provided by the tank supplier, and has a high accuracy and reliability within an error range of 0.03%.

참고문헌 (8)

  1. 최동준, "차압센서를 이용한 극저온 액화가스 저장용기의 액면측정장치 설계에 관한 연구", 한국마린엔지니어링학회지, 37(4), pp.384~390 (2013), 한국마린엔지니어링학회[DOI]
  2. 이승하, "극저온까지 온도변화에 따른 질소 충전 소형 금속 벨로우즈의 변형 해석", 한국정밀공학회지, 26(10), pp.81~88 (2009), 한국정밀공학회
  3. J. S. Park, "Design of measurement system of liquefied gas level with very low temperature", J. Korean Soc. Precis. Eng., 27(5), pp.1039~1040 (2010)
  4. H. H. Kim, "A study on the structural stability analysis of the cryogenic value", Proc. Korean Soc. Precis. Eng. Conf., pp.569~570 (2008)
  5. "Sensor Solution-Pressure sensor"[URL]
  6. 백승현, "무선센서네트워크 기반 공기질 측정을 위한 비분산적외선 복합가스측정시스템", 대한임베디드공학회논문지, 11(5), pp.299~304 (2016), 대한임베디드공학회[DOI]
  7. 신광식, "무선 센서네트워크기술을 활용한 Ad-hoc 홈 네트워크시스템", 센서학회지, 16(2), pp.142~149 (2007), 한국센서학회
  8. "User Manual-Air-Bon F400SN"[URL]