수중 전기장 센서용 다중 막대형 은-염화은 전극 개발
Development of Multi-rod Type Ag–AgCl Electrodes for an Underwater Electric Field Sensor
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Multi-rod type Ag–AgCl electrodes have been developed for use in underwater electric field sensors. The developed cylindrical electrode had a diameter of 50 mm and a height of 130 mm. The electrode had five Ag–AgCl rods with a diameter of 2 mm and a height of 80 mm to enlarge the reaction surface area. Each Ag–AgCl rod was fabricated under the same conditions as the usual anodizing method in an electrolyte. The two developed electrodes were placed in the center of a 500-mm long, 400-mm wide, and 300-mm high acrylic tank filled with artificial seawater, at an interval of 100 mm, to evaluate their characteristics as uniaxial underwater electric field sensors. The underwater external electric field was generated using titanium plate electrodes installed at both ends of the tank. The noise level at 1 Hz of the developed electrode was approximately 3.7 nV/√Hz. The reception of the underwater electric field signal using the developed electrode was linear, within an error of approximately 0.6 %, in the range of 1–10000 μV/m at 1 Hz. In addition, its frequency response was flat within an error of 1.1 % in the range of 1–1000 Hz at 10000 μV/m.
Abstract
Multi-rod type Ag–AgCl electrodes have been developed for use in underwater electric field sensors. The developed cylindrical electrode had a diameter of 50 mm and a height of 130 mm. The electrode had five Ag–AgCl rods with a diameter of 2 mm and a height of 80 mm to enlarge the reaction surface area. Each Ag–AgCl rod was fabricated under the same conditions as the usual anodizing method in an electrolyte. The two developed electrodes were placed in the center of a 500-mm long, 400-mm wide, and 300-mm high acrylic tank filled with artificial seawater, at an interval of 100 mm, to evaluate their characteristics as uniaxial underwater electric field sensors. The underwater external electric field was generated using titanium plate electrodes installed at both ends of the tank. The noise level at 1 Hz of the developed electrode was approximately 3.7 nV/√Hz. The reception of the underwater electric field signal using the developed electrode was linear, within an error of approximately 0.6 %, in the range of 1–10000 μV/m at 1 Hz. In addition, its frequency response was flat within an error of 1.1 % in the range of 1–1000 Hz at 10000 μV/m.
참고문헌 (16)
- R. Mackie, "Joint 3D inversion of marine CSEM and MT data", SEG Tech. Program Expanded Abstr, pp.574~578 (2007)
- X. Wang, "Underwater target detection based on electric-field sensor line array", Appl. Mech. Mater, 713-715, pp.337~342 (2015)
- G. Petiau, "Noise, temperature coefficient, and long time stability of electrodes for telluric observations", Geophys. Prospect, 28(5), pp.792~804 (1980)
- B. Rostami, "Development of an enhanced porosity AgAgCl reference electrode with improved stability", Eng. Res. Express, 1(1), pp.015039(1)~015039(9) (2019)
- Y. H. Heo, "Fabrication and Evaluation of Ag", AgCl Reference Electrode, 2007, pp.3(1), 33~38
- A. Albulbul, "Evaluating Major Electrode Types for Idle Biological Signal Measurements for Modern Medical Technology", Bioeng, 3(3), pp.20(1)~20(10) (2016)
- 정일손, "다전극 산소 센서를 이용한 고분자 막의 산소 투과도 측정 장치 연구", 센서학회지, 21(3), pp.229~234 (2012), 한국센서학회[DOI]
- S. Kim, "Facial Fabrication and Characterization of Novel Ag", AgCl Chloride Ion Sensor Based on Gel-Type Electrolyte, 2020, pp.8, 574986(1)~574986(13)
- H. Ha, "The effect of silver chloride formation on the kinetics of silver dissolution in chloride solution", Electrochim. Acta, 56(7), pp.2781~2791 (2011)
- S. M. Heintzelman, "Characterization and Analysis of Electric-field Sensors", Proc. IEEE Ind. Appl. Soc. Annu. Meet, pp.1~8 (2015)
- E. Huigen, "Investigation into the origin of the noise of surface electrodes", Med. Biol. Eng. Comput, 40(3), pp.332~338 (2002)
- Wang Z, "Development and evaluation of an ultralow-noise sensor system for marine electric field measurements", Sensor Actuat A : Phys, 213, pp.70~78 (2014)
- J. Zai, "Fabrication of novel ag", agcl electrode pair on the template of carbon foam as marine electric field sensor and its electrochemical performances, 2017, pp.23(8), 2213~2219
- W. Luo, "Development and characterization of high-stability allsolid-state porous electrodes for marine electric field sensors", Sens. Actuators A: Phys, 301, pp.111730(1)~111730(12) (2020)
- S. C. Webb, "A seafloor electric field instrument", J. Geomagn. Geoelectr, 37(12), pp.1115~1129 (1985)
- D. Shmilovitz, "On the Definition of Total Harmonic Distortion and Its Effect on Measurement Interpretation", IEEE T. Power Deliver, 20(1), pp.526~528 (2005)
