Removal of a Left Upper Lobar Bronchial Foreign Body Using Fogarty Catheter and Rigid Bronchoscope
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Airway foreign body aspiration in children can lead to accidental death, due to the foreign body itself or the removal procedure. Depending on its location, removal of the foreign body can be challenging. Here, we present a case of successful removal of a foreign body from the left upper lobar bronchus via ventilating bronchoscopy with a rigid bronchoscope and Fogarty arterial embolectomy catheter. Tracheobronchial foreign bodies in locations that are difficult to reach with forceps, due to an acute angle or the small diameter of the pediatric bronchial tree, can be effectively removed with a Fogarty arterial embolectomy catheter.
Abstract
Airway foreign body aspiration in children can lead to accidental death, due to the foreign body itself or the removal procedure. Depending on its location, removal of the foreign body can be challenging. Here, we present a case of successful removal of a foreign body from the left upper lobar bronchus via ventilating bronchoscopy with a rigid bronchoscope and Fogarty arterial embolectomy catheter. Tracheobronchial foreign bodies in locations that are difficult to reach with forceps, due to an acute angle or the small diameter of the pediatric bronchial tree, can be effectively removed with a Fogarty arterial embolectomy catheter.
참고문헌 (10)
- Fidkowski CW, "The anesthetic considerations of tracheobronchial foreign bodies in children : A literature review of 12, 979 cases", Anesth Analg, 111(4), pp.1016~1025 (2010)
- Akhter J, "Inadvertent removal of foreign body via a flexible fiberoptic bronchoscope in a 4-year-old boy", Pediatr Pulmonol, 18(1), pp.51~52 (1994)
- Wolach B, "Aspirated foreign bodies in the respiratory tract of children : Eleven years experience with 127 patients", Int J Pediatr Otorhinolaryngol, 30(1), pp.1~10 (1994)
- 임상호, "Bronchial foreign body removal under general anesthesia with a modified port, a fogarty balloon catheter and a grasping forceps", Korean Journal of Anesthesiology, 61(2), pp.177~179 (2011), 대한마취통증의학회
- Mackle T, "The combined use of a Fogarty balloon with extraction forceps for the controlled retrieval of an endobronchial foreign body", Int J Pediatr Otorhinolaryngol, 60(2), pp.163~165 (2001)
- Landy C, "Use of a Fogarty catheter after tracheobronchial inhalation of a bead", Trop Doct, 42(4), pp.219~220 (2012)
- Nyman AG, "Endobronchial foreign body removal using a coronary artery balloon catheter", J Bronchology Interv Pulmonol, 25(4), pp.e50~e51 (2018)
- Hight DW, "The treatment of retained peripheral foreign bodies in the pediatric airway", J Pediatr Surg, 16(5), pp.694~699 (1981)
- Wankhede RG, "Successful removal of foreign body bronchus using C-arm-guided insertion of Fogarty catheter through plastic bead", Indian J Crit Care Med, 21(2), pp.96~98 (2017)
- Elsharkawy H, "Management challenges in the passing-through technique using a fogarty catheter to remove an endobronchial foreign body from an infant", Ochsner J, 15(1), pp.110~113 (2015)