Development of Laryngeal Stroboscopic Effect With Continuous Light Source
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background and Objectives Most laryngeal imaging modalities used continuous light source. However, videostroboscopy adopted the unique stroboscopic flashing light triggered externally and is consistent with fundamental voice frequencies. If laryngeal stroboscopic effect could be obtained in the field of continuous illumination, it woud be more compatible with conventional video. In this study, we established the mathematical algorithm for stroboscopic effect with continuous light and tried to determine the feasibility of laryngeal stroboscopic effect with conventional laryngoscopy using continuous light in the mechanical model. Materials and Method The mechanical model of fan motor system was used to validate to the present study. Rotational images of the fan motor were captured using conventional laryngoscope with continuous light source. Results On the basis of the mathematical model, the optimal ranges of the frequency for stroboscopic effect were expected as (multiples of sampling rate [S])±(S/5). In the fan motor model, the stroboscopic effects could be confirmed on the basis of the mathematical model using conventional videolaryngoscopy with continuous light source. Conclusion Laryngeal stroboscopic effect with continuous light source might be feasible. The stroboscopic effect with continuous light would be expected to provide greater compatibility to integrate with the other imaging modalities for the vocal folds.
Abstract
Background and Objectives Most laryngeal imaging modalities used continuous light source. However, videostroboscopy adopted the unique stroboscopic flashing light triggered externally and is consistent with fundamental voice frequencies. If laryngeal stroboscopic effect could be obtained in the field of continuous illumination, it woud be more compatible with conventional video. In this study, we established the mathematical algorithm for stroboscopic effect with continuous light and tried to determine the feasibility of laryngeal stroboscopic effect with conventional laryngoscopy using continuous light in the mechanical model. Materials and Method The mechanical model of fan motor system was used to validate to the present study. Rotational images of the fan motor were captured using conventional laryngoscope with continuous light source. Results On the basis of the mathematical model, the optimal ranges of the frequency for stroboscopic effect were expected as (multiples of sampling rate [S])±(S/5). In the fan motor model, the stroboscopic effects could be confirmed on the basis of the mathematical model using conventional videolaryngoscopy with continuous light source. Conclusion Laryngeal stroboscopic effect with continuous light source might be feasible. The stroboscopic effect with continuous light would be expected to provide greater compatibility to integrate with the other imaging modalities for the vocal folds.
참고문헌 (19)
- Shaw HS, "Mucosal wave : a normophonic study across visualization techniques", J Voice, 22(1), pp.23~33 (2008)
- Krausert CR, "Mucosal wave measurement and visualization techniques", J Voice, 25(4), pp.395~405 (2011)
- Jędra K, "Videostrobokymography and phonovibrogram as a new methods for analysis of vocal fold vibration", Pol Otorhino Rev, 4(2), pp.19~26 (2015)
- Schönhärl E, "Die stroboskopie in der praktischen laryngologie" (1960), Thieme
- Hernández Sandemetrio R, "What is the contribution of stroboscopy in the diagnosis of voice disorders?", Acta Otorrinolaringol Esp, 61(2), pp.145~148 (2010)
- Shinghal T, "Highspeed video or video stroboscopy in adolescents : which sheds more light?", Otolaryngol Head Neck Surg, 151(6), pp.1041~1045 (2014)
- Yanagisawa E, "Videolaryngoscopy. A comparison of fiberscopic and telescopic documentation", Ann Otol Rhinol Laryngol, 92(5 Pt 1), pp.430~436 (1983)
- Svec JG, "Videokymography : high-speed line scanning of vocal fold vibration", J Voice, 10(2), pp.201~205 (1996)
- Hirose H, "High-speed digital imaging of vocal fold vibration", Acta Otolaryngol Suppl, 458, pp.151~153 (1988)
- Wang S, "Development of two-dimensional scanning videokymography for analysis of vocal fold vibration", J Korean Soc Laryngol Phoniatr Logop, 24(2), pp.107~111 (2013)
- Wang SG, "The first application of the two-dimensional scanning videokymography in excised canine larynx model", J Voice, 30(1), pp.1~4 (2016)
- Park HJ, "Imaging and analysis of human vocal fold vibration using two-dimensional(2D)scanning videokymography", J Voice, 30(3), pp.345~353 (2016)
- Mehta DD, "Voice production mechanisms following phonosurgical treatment of early glottic cancer", Ann Otol Rhinol Laryngol, 119(1), pp.1~9 (2010)
- Eysholdt U, "Vocal fold vibration irregularities caused by different types of laryngeal asymmetry", Eur Arch Otorhinolaryngol, 260(8), pp.412~417 (2003)
- Qiu Q, "A new generation videokymography for routine clinical vocal fold examination", Laryngoscope, 116(10), pp.1824~1828 (2006)
- Qiu Q, "An automatic method to quantify the vibration properties of human vocal folds via videokymography", Folia Phoniatr Logop, 55(3), pp.128~136 (2003)
- Tarafder KH, "Video laryngostroboscopy", Bangladesh J Otorhinolaryngol, 18(2), pp.171~178 (2012)
- Mendelsohn AH, "The diagnostic role of high-speed vocal fold vibratory imaging", J Voice, 27(5), pp.627~631 (2013)
- Verikas A, "Advances in laryngeal imaging", Eur Arch Otorhinolaryngol, 266(10), pp.1509~1520 (2009)
