The Significance of the Strong Ion Gap in Predicting Acute Kidney Injury and In-hospital Mortality in Critically Ill Patients with Acute Poisoning
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: A high anion gap (AG) is known to be a significant risk factor for serious acid-base imbalances and death in acute poisoning cases. The strong ion difference (SID), or strong ion gap (SIG), has recently been used to predict in-hospital mortality or acute kidney injury (AKI) in patients with systemic inflammatory response syndrome. This study presents a comprehensive acidbase analysis in order to identify the predictive value of the SIG for disease severity in severe poisoning. Methods: A cross-sectional observational study was conducted on acute poisoning patients treated in the emergency intensive care unit (ICU) between December 2015 and November 2020. Initial serum electrolytes, base deficit (BD), AG, SIG, and laboratory parameters were concurrently measured upon hospital arrival and were subsequently used along with Stewart’s approach to acid-base analysis to predict AKI development and in-hospital death. The area under the receiver operating characteristic curve (AUC) and logistic regression analysis were used as statistical tests. Results: Overall, 343 patients who were treated in the intensive care unit were enrolled. The initial levels of lactate, AG, and BD were significantly higher in the AKI group (n=62). Both effective SID [SIDe] (20.3 vs. 26.4 mEq/L, p<0.001) and SIG (20.2 vs. 16.5 mEq/L, p<0.001) were significantly higher in the AKI group; however, the AUC of serum SIDe was 0.842 (95% confidence interval [CI]=0.799-0.879). Serum SIDe had a higher predictive capacity for AKI than initial creatinine (AUC=0.796, 95% CI=0.749-0.837), BD (AUC=0.761, 95% CI=0.712-0.805), and AG (AUC=0.660, 95% CI=0.607-0.711). Multivariate logistic regression analyses revealed that diabetes, lactic acidosis, high SIG, and low SIDe were significant risk factors for in-hospital mortality. Conclusion: Initial SIDe and SIG were identified as useful predictors of AKI and in-hospital mortality in intoxicated patients who were critically ill. Further research is necessary to evaluate the physiological nature of the toxicant or unmeasured anions in such patients.
Abstract
Purpose: A high anion gap (AG) is known to be a significant risk factor for serious acid-base imbalances and death in acute poisoning cases. The strong ion difference (SID), or strong ion gap (SIG), has recently been used to predict in-hospital mortality or acute kidney injury (AKI) in patients with systemic inflammatory response syndrome. This study presents a comprehensive acidbase analysis in order to identify the predictive value of the SIG for disease severity in severe poisoning. Methods: A cross-sectional observational study was conducted on acute poisoning patients treated in the emergency intensive care unit (ICU) between December 2015 and November 2020. Initial serum electrolytes, base deficit (BD), AG, SIG, and laboratory parameters were concurrently measured upon hospital arrival and were subsequently used along with Stewart’s approach to acid-base analysis to predict AKI development and in-hospital death. The area under the receiver operating characteristic curve (AUC) and logistic regression analysis were used as statistical tests. Results: Overall, 343 patients who were treated in the intensive care unit were enrolled. The initial levels of lactate, AG, and BD were significantly higher in the AKI group (n=62). Both effective SID [SIDe] (20.3 vs. 26.4 mEq/L, p<0.001) and SIG (20.2 vs. 16.5 mEq/L, p<0.001) were significantly higher in the AKI group; however, the AUC of serum SIDe was 0.842 (95% confidence interval [CI]=0.799-0.879). Serum SIDe had a higher predictive capacity for AKI than initial creatinine (AUC=0.796, 95% CI=0.749-0.837), BD (AUC=0.761, 95% CI=0.712-0.805), and AG (AUC=0.660, 95% CI=0.607-0.711). Multivariate logistic regression analyses revealed that diabetes, lactic acidosis, high SIG, and low SIDe were significant risk factors for in-hospital mortality. Conclusion: Initial SIDe and SIG were identified as useful predictors of AKI and in-hospital mortality in intoxicated patients who were critically ill. Further research is necessary to evaluate the physiological nature of the toxicant or unmeasured anions in such patients.
참고문헌 (24)
- Cusack RJ, "The strong ion gap does not have prognostic value in critically ill patients in a mixed medical", surgical adult ICU, 2002, pp.28, 864~869
- Shen X, "The prognostic value of the strong ion gap in acute pancreatitis", J Crit Care, 36, pp.140~145 (2016)
- Berndtson AE, "Strong ion difference and gap predict outcomes after adult burn injury", J Trauma Acute Care Surg, 75, pp.555~560 (2013)
- Zehtabchi S, "Utility of Stewart’s strong ion difference as a predictor of major injury after trauma in the ED", Am J Emerg Med, 25, pp.938~941 (2007)
- Ho KM, "A comparison of prognostic significance of strong ion gap(SIG)with other acid-base markers in the critically ill : a cohort study", J Intensive Care, 4, pp.43~ (2016)
- Kaneko M, "The Significance of Strong Ion Gap for Predicting Return of Spontaneous Circulation in Patients with Cardiopulmonary Arrest", Open Med(Wars), 12, pp.33~38 (2017)
- HE Persson, "Poisoning severity score. Grading of acute poisoning", J Toxicol Clin Toxicol, 36, pp.205~213 (1998)
- 류기순, "Early Detection and Staging of Acute Kidney Injury in Non-traumatic Rhabdomyolysis in Emergency Department", 대한응급의학회지, 26(5), pp.370~378 (2015), 대한응급의학회
- Zheng CM, "Metabolic acidosis and strong ion gap in critically ill patients with acute kidney injury", Biomed Res Int, 2014, pp.819528~ (2014)
- Ahn JY, "Plasma neutrophil gelatinase-associated lipocalin as a predictive biomarker for the detection of acute kidney injury in adult poisoning", Clin Toxicol(Phila), 54, pp.127~133 (2016)
- 이선효, "The Anion Gap Is a Predictive Clinical Marker for Death in Patients with Acute Pesticide Intoxication", Journal of Korean Medical Science, 31(7), pp.1150~1159 (2016), 대한의학회
- Shah AD, "Understanding lactic acidosis in paracetamol(acetaminophen)poisoning", Br J Clin Pharmacol, 71, pp.20~28 (2011)
- Lee SB, "Base deficit is a predictor of mortality in organophosphate insecticide poisoning", Hum Exp Toxicol, 37, pp.118~124 (2018)
- "The clinical role of serum albumin in Organophospate poisoning", Basic Clin Pharmacol Toxicol, 128, pp.605~614 (2021)
- 신태용, "응급센터 중환자에서 측정한 초기 측정되지 않은 음이온(unmeasured anions): 중환자의 이환율을 예측에 도움이 되는가?", 대한응급의학회지, 17(5), pp.454~462 (2006), 대한응급의학회
- Park S, "Diagnosis of Acid-base Imbalance by Stewart’s Physicochemical Approach and Mortality Prediction in Severe Burn Patients with Inhalation Injury", Korean J Crit Care Med, 21, pp.17~27 (2006)
- 김상철, "응급센터에 내원한 중환자에서 초기 Strong Ion Gap의 예후적 가치", 대한응급의학회지, 16(1), pp.45~50 (2005), 대한응급의학회
- Aduen J, "Relationship between blood lactate concentrations and ionized calcium, glucose, and acid-base status in critically ill and noncritically ill patients", Crit Care Med, 23, pp.246~252 (1995)
- Gunnerson KJ, "Is there a difference between strong ion gap in healthy volunteers and intensive care unit patients?", J Crit Care, 25, pp.520~524 (2010)
- Funk GC, "The strong ion gap and outcome after cardiac arrest in patients treated with therapeutic hypothermia : a retrospective study", Intensive Care Med, 35, pp.232~239 (2009)
- Zhao Y, "Serum anion gap at admission as a predictor of the survival of patients with paraquat poisoning: A retrospective analysis", Medicine (Baltimore), 99, pp.e21351~ (2020)
- Sen S, "Strong ion gap is associated with mortality in pediatric burn injuries", Journal of burn care & research: official publication of the American Burn Association, 35, pp.337~341 (2014)
- 박형훈, "글리포세이트 중독 환자에서 급성 신손상 발생의 임상 양상과 위험 인자", 대한임상독성학회지, 18(2), pp.110~115 (2020), 대한임상독성학회[DOI]
- Hill NR, "Global Prevalence of Chronic Kidney Disease - A Systematic Review and Meta-Analysis", PLoS One, 11, pp.e0158765~ (2016)