폐기물 처리시설에서의 악취 및 환기에 관한 연구

A study on odor and ventilation in waste treatment facilities

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Recently, as the income level and quality of life have improved, the desire for a pleasant environment has increased, and a deodorization plan is required through thorough prevention and diffusion of odorous substances in waste treatment facilities recognized as hateful facilities, appropriate collection, and selection of the right prevention facilities. In this study, a waste disposal facility was modeled and computerized analysis for odor and ventilation analysis was conducted. Numerical analysis of the waste treatment facility was performed at the size of the actual plant. CATIA V5 R16 for numerical model generation and ANSYS FLUENT V.13 for general purpose flow analysis were used as analysis tools. The average air-age of the internal was 329 seconds, and the air-flow velocity was 0.384m/s. The odor diffusion analysis inside the underground pump room showed congestion-free air circulation through streamline distribution and air-age distribution. This satisfies the ASHRAE criteria. In addition, the results of diffusion analysis of odorous substances such as ammonia, hydrogen sulfide, methyl mercaptan and dimethyl sulfide were all expected to satisfy the regulatory standards. Particularly in the case of the waste loading area, the air-flow velocity was 0.297m/s, and the result of meeting the regulatory standards with 0.167ppm of ammonia, 0.00548ppm of hydrogen sulfide, 0.003ppm of methyl mercaptan, and 0.003ppm of dimethyl sulfide was found.

Abstract

Recently, as the income level and quality of life have improved, the desire for a pleasant environment has increased, and a deodorization plan is required through thorough prevention and diffusion of odorous substances in waste treatment facilities recognized as hateful facilities, appropriate collection, and selection of the right prevention facilities. In this study, a waste disposal facility was modeled and computerized analysis for odor and ventilation analysis was conducted. Numerical analysis of the waste treatment facility was performed at the size of the actual plant. CATIA V5 R16 for numerical model generation and ANSYS FLUENT V.13 for general purpose flow analysis were used as analysis tools. The average air-age of the internal was 329 seconds, and the air-flow velocity was 0.384m/s. The odor diffusion analysis inside the underground pump room showed congestion-free air circulation through streamline distribution and air-age distribution. This satisfies the ASHRAE criteria. In addition, the results of diffusion analysis of odorous substances such as ammonia, hydrogen sulfide, methyl mercaptan and dimethyl sulfide were all expected to satisfy the regulatory standards. Particularly in the case of the waste loading area, the air-flow velocity was 0.297m/s, and the result of meeting the regulatory standards with 0.167ppm of ammonia, 0.00548ppm of hydrogen sulfide, 0.003ppm of methyl mercaptan, and 0.003ppm of dimethyl sulfide was found.

참고문헌 (6)

  1. 송기혁, "극저온 가스와 MQL(minimum quantity lubrication)의 복합 분사를 위한 하이브리드 노즐 설계에 관한 전산유체역학 해석", Design & Manufacturing, 13(3), pp.41~47 (2019), 한국금형공학회[DOI]
  2. 이민, "자연대류에서 유한요소법을 이용한 히트싱크의 성능비교", Design & Manufacturing, 12(1), pp.31~35 (2018), 한국금형공학회[DOI]
  3. 정성택, "친환경 고생산성을 위한 단일 쿠션 팩트 내 화장품 용기의 사출 시뮬레이션 분석", Design & Manufacturing, 12(2), pp.51~56 (2018), 한국금형공학회[DOI]
  4. Y. I. Kwon, "A Study on the Design Method of HVAC System with Air-Age on Underground Shopping Center", Int. J. of Air-conditioning and Refrigeration, 27(2), pp.57~62 (2015)
  5. 김영준, "환경에너지 종합타운 조성 타당성에 관한 연구", 설비공학 논문집, 23(2), pp.164~171 (2011), 대한설비공학회
  6. ANSYS Inc, "ANSYS Fluent 13.0 User’s Guide", ~ (2014)

관련 논문AI추천

이 간행물의 다른 논문 (9건)