본문 바로가기
KERD
논문KCI 등재

비조영증강 MDCT에서 관전압과 절편 두께에 따른 요로결석의 HU 측정

HU Measurement of Urinary Stone according to the Tube Voltage and Slice Thickness in Non-enhancement MDCT

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

To distinguish urinary stones, we tried to identify the components of urinary stone using HU of nonenhancement MDCT. HU was measured according to the tube voltage and the slice thickness of the section of urinary stone. After injecting urinary stone into a small plastic bottle, experimental phantom was prepared using pork similar to human body. 640 slice MDCT. HU of urinary stone was measured according to each tube voltage and slice thickness in the obtained images. HU of urinary stones according to tube voltage were 135 kVp (373.68±30.20 HU), 100 kVp (525.94±44.93 HU) and 80 kVp (691±80.80 HU), and the slice thickness was 0.5 mm (752±25.71 HU) minimum (545.96±29.89 HU), 1.5 mm (462.68±46.35 HU), 2 mm (360.43±66.19 HU). It was found that the HU of urinary stone was increased with decreasing tube voltage, and the HU of urinary stone was decreased with increasing thickness of the section. Non-enhancement MDCT for urinary stone is thought to be useful for the diagnosis of urinary stone using thin slice thickness using low tube voltage.

Abstract

To distinguish urinary stones, we tried to identify the components of urinary stone using HU of nonenhancement MDCT. HU was measured according to the tube voltage and the slice thickness of the section of urinary stone. After injecting urinary stone into a small plastic bottle, experimental phantom was prepared using pork similar to human body. 640 slice MDCT. HU of urinary stone was measured according to each tube voltage and slice thickness in the obtained images. HU of urinary stones according to tube voltage were 135 kVp (373.68±30.20 HU), 100 kVp (525.94±44.93 HU) and 80 kVp (691±80.80 HU), and the slice thickness was 0.5 mm (752±25.71 HU) minimum (545.96±29.89 HU), 1.5 mm (462.68±46.35 HU), 2 mm (360.43±66.19 HU). It was found that the HU of urinary stone was increased with decreasing tube voltage, and the HU of urinary stone was decreased with increasing thickness of the section. Non-enhancement MDCT for urinary stone is thought to be useful for the diagnosis of urinary stone using thin slice thickness using low tube voltage.

참고문헌 (16)

  1. Borghi L, "Comparison of two diets for the prevention of recurrent stones in idiopathic hypercalciuria", N. Engl. J. Med., 346(2), pp.77~84 (2002)[DOI]
  2. Kakinuma R, "Detection failures in spiral CT screening for lung cancer: analysis of CT findings", Radiology, 212(1), pp.61~66 (1999)[DOI]
  3. 김홍석, "요석 환자에서 비조영증강 나선식 전산화단층촬영술의 유용성", Investigative and Clinical Urology, 44(8), pp.796~800 (2003), 대한비뇨의학회
  4. 이민우, "요산석 환자의 혈중 및 요중 생화학적 특성", Investigative and Clinical Urology, 47(7), pp.712~716 (2006), 대한비뇨의학회
  5. Lee SJ, "Clinical observations in 4468 cases of patients with urinary stones", Korean J. Urol., 37(8), pp.877~887 (1996)
  6. Leusmann DB, "Recurrence rates and severity of urinary calculi", Scand. J. Urol. Nephrol., 29(3), pp.279~283 (1995)[DOI]
  7. Levine JA, "Ureteral calculi in patients with flank pain correlation of plain radiography with unenhanced helical CT", Radiology, 204(1), pp.27~31 (1997)[DOI]
  8. Mitcheson HD, "Determination of the chemical composition of urinary calculi by computerized tomography", J. Urol., 130(4), pp.814~819 (1983)[DOI]
  9. Mostafavi MR, "Accurate determination of chemical composition of urinary calculi by spiral computerized tomography", J. Urol., 159(3), pp.673~675 (1998)[DOI]
  10. Nakada SY, "Determination of stone composition by noncontrast spiral computed tomography in the clinical setting", Urology, 55(6), pp.816~819 (2000)[DOI]
  11. Newhouse JH, "Computed tomographic analysis of urinary calculi", Am. J. Roentgenol., 142(3), pp.545~548 (1984)[DOI]
  12. Saw KC, "Helical CT of urinary calculi: effect of stone composition, stone size, and scan collimation", Am. J. Roentgenol., 175(2), pp.329~332 (2000)[DOI]
  13. Sierakowski R, "The frequency of urolithiasis inhospital discharge diagnosis in the United States", Invest. Urol., 15(6), pp.438~441 (1978)
  14. Uribarri J, "The first kidney stone", Ann. Intern. Med., 111(12), pp.1006~1009 (1989)[DOI]
  15. Yilmaz S, "Renal colic: comparison of spiral CT, US and IVU in the detection of ureteral calculi", Eur. Radiol., 8(2), pp.212~217 (1998)[DOI]
  16. Zarse CA, "Helical computed tomography accurately reports urinary stone composition using attenuation values: in vitro verification using high-resolution micro-computed tomography calibrated to fourier transform infrared microspectroscopy", Urology, 63(5), pp.828~833 (2004)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (8건)